Vega VEGAPULS 62 Quick Setup Manual - 6 Supplement
16
6 Supplement
VEGAPULS 62 • 4 … 20 mA/HART - two-wire
51872-EN-160620
6 Supplement
6.1 Technical data
Noteforapprovedinstruments
The technical data in the respective safety instructions are valid for approved instruments (e.g. with
Exapproval).Thesedatacandifferfromthedatalistedherein,forexampleregardingtheprocess
conditions or the voltage supply.
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
1)
Ʋ Single chamber housing
– 1xcableglandM20x1.5(cable:ø5…9mm),1x
blindplugM20x1.5
or:
– 1xclosingcapM20x1.5;1xblindplugM20x1.5
or:
– 1xclosingcap½NPT,1xblindplug½NPT
or:
– 1␣xplug(dependingontheversion),1␣xblindstopper
M20␣x␣1.5
Ʋ Double chamber housing
– 1xcableentryM20x1.5(cable:ø5…9mm),1x
blindplugM20x1.5;1xblindplugM16x1.5or
optionallyavailablewith1xplugM12x1forexternal
display and adjustment unit
or:
– 1xclosingcap½NPT,1xblindplug½NPT,1xblind
plugM16x1.5oroptionally1xplugM12x1forexter-
nal display and adjustment unit
or:
– 1xplug(dependingontheversion),1xblindplug
M20x1.5;1xblindplugM16x1.5oroptionallyavail-
ablewith1xplugM12x1forexternaldisplayand
adjustment unit
Spring-loaded terminals for wire cross-
section
< 2.5 mm² (AWG 14)
Voltage supply
Operating voltage U
B
Ʋ Non-Exinstrument
14 … 36 V DC
Ʋ EEx-iainstrument
14 … 30 V DC
Ʋ EEx-d-iainstrument
20 … 36 V DC
Operating voltage U
B
- illuminated display and adjustment module
Ʋ Non-Exinstrument
20 … 36 V DC
Ʋ EEx-iainstrument
20 … 30 V DC
Ʋ EEx-d-iainstrument
20 … 36 V DC
1)