D-Link DES-3828 - xStack Switch - Stackable User Manual - Mstp Port Information
xStack DES-3800 Series Layer 3 Stackable Fast Ethernet Managed Switch
94
conjunction with the VID List parameter.
VID List (1-4094)
This field is used to specify the VID range from configured VLANs set on the Switch.
Supported VIDs on the Switch range from ID number 1 to 4094. This field is
inoperable when configuring the CIST.
Click Apply to implement changes made.
To configure the parameters for a previously set MSTI, click on its hyperlinked MSTI IDnumber,
which will reveal the following window for configuration.
Figure 7- 24. Instance ID Settings window – modify
The user may configure the following parameters for a MSTI on the Switch.
Parameter
Description
MSTI ID
Displays the MSTI ID previously set by the user.
Type
This field allows the user to choose a desired method for altering the MSTI settings.
The user has four choices.
•
Add - Select this parameter to add VIDs to the MSTI ID, in conjunction with
the VID List parameter.
•
Remove - Select this parameter to remove VIDs from the MSTI ID, in con-
junction with the VID List parameter.
VID List (1-4094)
This field is used to specify the VID range from configured VLANs set on the Switch
that the user wishes to add to this MSTI ID. Supported VIDs on the Switch range from
ID number 1 to 4094. This parameter can only be utilized if the Type chosen is Add or
Remove.
Click Apply to implement changes made.
MSTP Port Information
This window displays the current MSTP Port Information and can be used to update the port
configuration for an MSTI ID. If a loop occurs, the MSTP function will use the port priority to select
an interface to put into the forwarding state. Set a higher priority value for interfaces to be selected for
forwarding first. In instances where the priority value is identical, the MSTP function will implement
the lowest MAC address into the forwarding state and other interfaces will be blocked. Remember that