Summary of COMBIVERT F5

  • Page 1

    C o m b i v e r t original manual mat.No. Rev. Dxf5zem-k001 1a gb installation manual encoder interfaces combivert with safety function sto f5-k/ -l/ -p.

  • Page 3: Table of Contents

    Gb - 3 contents table of contents 1. Preface ............................................................................................................. 5 1.1 information on special measures .......................................................................................5 1.2 documentation ...

  • Page 4: Listoffigures

    Gb - 4 contents listoffigures figure 1: demounting of the device housing d and e ............................................................10 figure 2: installation of the encoder interface housing d and e ............................................ 11 figure 3: demounting the device housing g an...

  • Page 5

    Gb -5 preface 1. Preface 1.1 information on special measures the used pictograms have following significance: danger is used, if death or serious bodily injury may be the consequence of non-observance of the measure. Warning is used, if bodily injury and/or substantial property damage may be the con...

  • Page 6

    Gb -6 preface tests can only be done within the application by the machine manufacturer. They must be repeated, even if only parts of hardware, software or the unit adjustment are modi- fied. Unauthorised opening and tampering may lead to bodily injury and property damage and may entail the loss of ...

  • Page 7

    Gb -7 preface 1.6 product description this manual describes the installation or replacement of encoder interface cards in unit ver- sion combivert f5 with safety function sto. Attention permissible combinations only combinations released by keb are permissible for replacement or installation of en- ...

  • Page 8

    2. Safety instructions danger electric shock frequency inverter / servo drives contain dangerous voltages which can cause death or serious injury. In operation, drive converters, depending on their degree of protection, may have live, uninsulated, and possibly also moving and hot surfaces. In case o...

  • Page 9

    Warning do not open any electrical connections no internal electrical connections may be opened during installation or changing of the encoder interface. The certification for "functional safety" expires in case of contravention. The opening of electrical connections with the following required test...

  • Page 10

    3. Mechanical installation 3.1 housing d and e the mechanical installation is dependent on the housing. The housing can be identified through the 7th digit of the material number: • xxf5xxd-xxxx => housing d • xxf5xxe-xxxx => housing e 3.1.1 demounting the device 1 2 3 4 1 fixing bolt 2 cover plate ...

  • Page 11

    3.1.2 installation of the interface board 5 4 6 2 3 3 1 1 guide rail 2 socket connector 3 latch 4 interface board 5 fixing bolt 6 cover figure 2: installation of the encoder interface housing d and e installation of the interface board • insert the interface board (4) with the socket connector (2) a...

  • Page 12

    3.2 housing g and h the mechanical installation is dependent on the housing. The housing can be identified through the 7th digit of the material number: • xxf5xxg-xxxx => housing g • xxf5xxh-xxxx => housing h 3.2.1 demounting the device 4 5 3 2 1 1 cut-outs for cover fixing 4 operator 2 screws m2.5 ...

  • Page 13

    3.2.2 installation of the interface board 5 6 4 3 1 2 1 cut-outs for cover fixing 4 cover 2 screws m2.5 x 6 5 operator 3 interface board 6 cut-outs for cover fixing figure 4: installation of the interface board housing g and h installation of the interface board • plug the plug connector of the inte...

  • Page 14

    3.3 housing larger h the mechanical installation is dependent on the housing. The housing can be identified through the 7th digit of the material number: • xxf5xxp-xxxx => housing p • xxf5xxr-xxxx => housing r • xxf5xxu-xxxx => housing u • xxf5xxw-xxxx => housing w 2 7 5 6 4 1 3 8 1 interface board ...

  • Page 15

    Preparing for installation • pull cover fixings (5) upwards and remove cover (6) • solve operator (4) by pressing on the latch and pull upwards • solve screws (7) and remove carrier plate (3) • unscrew screws (2) from the distance pins (included distance pins are not required for devices with functi...

  • Page 16

    Gb -16 mechanical installation.

  • Page 17

    4. Return form the material number of the inverter changes in case of retrofitting or replacement of the en- coder interface against another version. In this case the following form must be filled out and send back to email rdf@keb.De . Company name: customer number (if known): previous number new n...

  • Page 18

    Gb -18 return form.

  • Page 19

    Gb - 19 notices.

  • Page 20

    Keb antriebstechnik austria gmbh ritzstraße 8 • a-4614 marchtrenk fon: +43 7243 53586-0 • fax: +43 7243 53586-21 net: www.Keb.At • mail: info@keb.At keb antriebstechnik herenveld 2 • b-9500 geraadsbergen fon: +32 5443 7860 • fax: +32 5443 7898 mail: vb.Belgien@keb.De keb power transmission technolog...