KEB COMBIVERT F5 Installation Manual - page 7
GB -7
Preface
1.6
Product description
This manual describes the installation or replacement of encoder interface cards in unit ver-
sion COMBIVERT F5 with safety function STO.
Attention
Permissible combinations
Only combinations released by KEB are permissible for replacement or installation of en-
coder interfaces.
The manual must be made available to any user who is responsible for the installation or
replacement of encoder interfaces.
Warning
Newormodifiedfunctionality
The functionality of the drive/servo can change by installation, alteration or replacement of
encoder interfaces. The functionality is dependent on the setting/programming by the ma-
chine manufacturer.
COMBIVERT F5 with safety function is marked in the material number in the fifth position with
the letters K, L or P:
• xxF5Kxx-xxxx
• xxF5Lxx-xxxx
• xxF5Pxx-xxxx
Additionally a „FS“ symbol must be printed on the type plate.
The connection and the settings of the inverter/servos are dependent on the encoder inter-
face type.
Info
Encoder interfaces are not safety components
Encoder interfaces are not safety components and they can be changed/installed without
anew safety test. No electrical connections between carrier board (control board) and power
unit may be opened during installation.