2.3.1 Assembly of the wires to PUSh IN terminals
Attention
Malfunctions caused by loose cable connections and to short wire-
end ferrules!
► Use wire-end ferrules according to
table “Wire-end ferrules and strip-
ping length”
.
► Strip cable according to
table “Wire-end ferrules and stripping length”
.
Cross-section
Wire-end ferrule
Metal sleeve
length
Stripping
length
0.50 mm
2
with plastic collars
(
DIN 46228-4
)
10 mm
12 mm
0.75 mm
2
12 mm
14 mm
1.00 mm
2
12 mm
15 mm
1.50 mm
2
without plastic collars
(
DIN 46228-1
)
10 mm
10 mm
0.14…1.5 mm
2
single-wireorfine-
wire
without wire-end
ferrule
–
10…15 fmm
Table 6:
Wire-end ferrules and stripping length
Front view
Side view
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
a)
b)
a) Pusher
b) Connecting wire hole
Figure 2:
Assembly of the control cable
•
Press pusher by hand. Insert connecting wires into the respective hole, that no
singlewirescanbeseenfromtheoutsideorbendoutward.Afirstresistancemust
be overcome when inserting. Release the pusher.
•
Checkthattheconnectingwireisfixedandcannotbepulled-out.Itisimportantto
ensure that the connecting wire and not the insulation is clamped. The connecting
wire can also be inserted without pressing the pusher in case of cross-sections
upto 1.00 mm².
20