KEB COMBIVERT F6 Instructions For Use Manual - page 36
36
2.9 brake control and temperature detection
X1C
PIN
Name
Notes
1
2
3
4
5
6
1
BR+
Brake control / output +
2
BR-
Brake control / output -
3
reserved
4
reserved
5
TA1
Temperature detection / input+
6
TA2
Temperature detection / input-
Figure 15: Assignment of the terminal block X1C
2.9.1 Specification and connection of the brake control
Name
BR+(X1C.1);BR-(X1C.2)
Function
Output to supply a brake
Output voltage
• minimum P24V_IN - 2.4 V
• maximum P24V_IN
maximum output current
2 A
Others
short-circuitproof,internalfree-wheelingpath;
internalfilterswitching
Table 22: Specification of the brake control
2
1
I
max=
2A
U=24Vdc
X1C
Figure 16: Example for the connection of the brake output at X1C
2.9.2 Specification and connection of the temperature detection
DANGeR
Use only sensors with basic insulation to mains potential !
Danger to life due to electric shock !
► The inputs of the temperature detection have „basic insulation“
against SELV voltage of the control.
► Asystemvoltage(Phase–PE)of300Visdefined.