2.9.3 Operation without temperature detection
Use of the COMBIVERT without evaluation of the temperature input:
• Deactivate the evaluation (pn33 =7)
or
• Install bridge between terminal X1C.5 and X1C.6 (dr33=1)
2.9.4 Connection of a kTy sensor
Attention
No protection of the motor winding in case of wrong connection.
► Operate KTY sensors in forward direction. Non-observance leads
incorrect measurement in the upper temperature range.
► KTY sensors may not be combined with other detections.
Name
TA1(X1C.5);TA2(X1C.6)
Function
Temperature sensor input
Stetting
dr33=0;KTY84/130
dr33=3;KTY83/110
Table 24: Connection of a KTY sensor
X1C.5 (TA1)
X1C.6 (TA2)
+
KTY84
Figure 17: Connection of a KTY sensor
2.9.5 Connection of PTC, temperature switch or PT1000
Name
TA1(X1C.5);TA2(X1C.6)
Function
Temperature sensor input
Stetting
dr33=1;PTCortemperatureswitch
dr33=4;PT1000
Table 25: Connection of PTC, temperature switch or PT1000