KEB COMBIVERT F6 Instructions For Use Manual - page 30
2.7.1.2 Blink code NET ST - LED in CAN mode
The NET ST - LED is a combination of RUN and ERROR LED according to IG-
CO_303_3v010400000.
Blink code NET ST - LED (red/green combination)
Status
Blink code
Description
Pre-Op
g-0
(200 ms-Raster)
Device in state PRE-OPERATIONAL
Stop
g-0-0-0-0-0
(200 ms-Raster)
Device in state STOPPED
Op
g
(continuous)
Device in state OPERATIONAL, no error
Bus off
r
(continuous)
CAN bus off
Invalid
Configuration
r-0
(200 ms-Raster)
Generalconfigurationerror.
Warning limit
reached
r-0-0-0-0-0
(200 ms-Raster)
The error counter in the CAN controller has
reached or exceeded a warning level.
Error control
event
r-0-r-0-0-0-0-0
(200 ms-Raster)
A Guard or Heartbeat Event has occured.
Sync error
r-0-r-0-r-0-r-0-0-0-0-0
(200 ms-Raster)
SYNC message not within the adjusted
time-out.
Legende:
r: red
g: green
0: off
The signals of red / green are shifted by
180°. When overlaying, red has priority.
Figure 13: Blink code „NET ST“ - LED in mode CAN
If a Real-time Ethernet module is installed, the function of the LED "NET ST" is
dependingontheactivefieldbusprotocol(fb68).
30