KEB COMBIVERT F6 Instructions For Use Manual - page 27
27
ENCODER INTERFACE
2.6 Diagnosis/visualisation
The integrated serial interface provides the following functions:
• Parameterization of the unit with the KEB software COMBIVIS
• Connection of a control operator
• DIN66019II is used as communication protocol.
Interface
Specification
RS485
Common-mode voltage range 0…12 V
RS232
ANSI TIA/EIA-232
Table 15: Serial interfaces
Name
Connecting cable
RS232 PC inverter (SubD-9 coupling - SubD-9 plug)
0058025-001D
RS232/USB (USB serial converter inclusive cable)
0058060-0040
Table 16: Connecting cable
Attention
No potential separation of the diagnostic interface to the control
voltage !
Malfunction or defect caused by voltage differences.
► Voltage differences > common-mode signal require potential equali-
zation line.
AcurrentXMLfileisrequiredfortheoperationwithCOMBIVIS6.Thedownload
can be done directly from COMBIVIS 6 while an Internet connection is present.
2.6.1 Assignment of the interface X4A
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
reserved
1
6
reserved
TxD (RS232)
2
7
DGND (reference potential)
RxD (RS232)
3
8
TxD-A (RS485)
RxD-A (RS485)
4
9
TxD-B (RS485)
RxD-B (RS485)
5
Figure 10: PIN assignment of the serial interface X4A