Vent-Axia Sentinel Kinetic B Left Installation & Commissioning Manual - page 27
Commissioning
Sentinel Kinetic MVHR Installation & Commissioning
27
Pressing the
button activates the boost airflow mode when extra
ventilation is required.
No. of presses
Boost action
(Control Mode 01)
1
Boosts for 30 minutes
2
Boosts for 60 minutes
3 Boosts
continuously
4
Back to Normal flow rate
N.B Additional airflow modes are available from the
button
when Control Mode 02 is selected in the start-up screens see
Appendix One for further details.
If the wireless boost option is fitted, this can be triggered from the
wireless transmitter/boost switch.
If the installation has switch sensors, is wired to the lighting, has Vent-
Wise sensors, Vent-Wise momentary switch or if the internal time
switch is set for periodic operation, operation will change from normal
to boost automatically. Pressing the
button will reveal a code to
show which device has activated boost.
s1 = Switch S/W1
s2 = Switch S/W2
s3 = Switch S/W3
s4 = Switch SW4
s5 = Switch SW5
v1 = Vent-Wise Input S/W1
v2 = Vent-Wise Input S/W2
v3 = Vent-Wise Input S/W3
ls = Switched live (LS)
w1-4 = Wireless controller
c1-3 = Internal Time switch
If running on boost due to pressing the
button, another device may
‘take over’ the boost. Flow will return to normal when that device
switches off. If a number of different devices are calling for boost flow,
the unit will run at boost until the last one has reverted to normal.
N.B Alternative functions are assigned to S/W1, S/W2, S/W3 &
SW5 when Control Mode 02 is selected in the start-up screens see
Appendix One for further details.
Boost Airflow
50 %