Xerox 7142 Service Manual - page 264
9 Troubleshooting
RJ-901C/RJ-900C Maintenance Manual
9-20
7
E 016 error
CPU Err
[06]
Address
exception error
(command
fetch):
Address error
in command
loading or
storing
3. Check serial
number of the
plotter.
4. Main board
assembly may be
defective.
•
Contact our
customer support
center.
•
Replace main board
assembly.
" 4 . 3 . 3
Replacing
Main Board
Assembly"
p.4-21
8
E 016 error
CPU Err
[07]
Bus exception
error (load or
store):
Bus error in
command
loading or
storing
1. Check serial
number of the
plotter.
2. Main board
assembly may be
defective.
•
Contact our
customer support
center.
•
Replace main board
assembly.
"4.3.3
Replacing
Main Board
Assembly"
p.4-21
9
E 016 error
CPU Err
[08]
System call
exception
error:
Abnormal
condition in
system call
10
E 016 error
CPU Err
[09]
Break point
exception
error:
Abnormal
condition in
break point
11
E 016 error
CPU Err
[10]
Reserved
command
exception
error:
Abnormal
condition in
reserved
command
12
E 016 error
CPU Err
[11]
Coprocessor
disabled
exception
error:
Abnormal
condition in
coprocessor
Table 9-6 Symptoms and Check Items for CPU System Serious Errors(Continued)
No.
Message
Event/
symptom
Check item
Action
Reference