"Transfer failed (Data
timeout)" is displayed
during transfer.
1. Are plotter and PC
connected correctly
with network cable
(crossover cable for
direct connection and
straight cable for
connection via hub)?
Yes: Proceed to (2).
No: Connect plotter and
PC correctly.
"7.3.3
Required
Environment"
p.7-11
2. Is network interface
card installed properly
in plotter?
Yes: Proceed to (3).
No: Install network
interface card properly.
"(1)
Replacing
NIC" p.4-16
3. Is PC IP address
appropriate?
Yes: Proceed to (4).
No: Adjust TCP/IP
properties from
[Properties] of [Local
Area Connection] in
[Network Connections]
setting of PC. PC and
plotter must have the same
subnet address (i.e.
192.168.1.1/24 and
192.168.1.253).
"7.3.3
Required
Environment"
p.7-11
4. Is any device of the
same IP address as PC
or plotter connected to
hub?
Yes: Disconnect the
applicable device from
network.
No: Proceed to (5).
-
5. Is plotter started in
board manager mode
and only POWER
LED turned on?
Yes: Proceed to (6).
No: Start plotter in board
manager mode. If LCD
displays nothing, engine
component may be
defective or firmware may
not be installed (including
power cutoff due to power
failure during installation
or other causes.)
"7.3.3
Required
Environment"
p.7-11
6. Is plotter IP address
appropriate? (Check
address according to
Section 6.3.)
Yes: Proceed to (7).
No: If LCD displays "No
Network Interface", check
implementation condition
of network interface card.
If network interface card is
implemented properly,
engine component or
network interface card
may be defective.
"(1)
Replacing
NIC" p.4-16
"4.3.3
Replacing
Main Board
Assembly"
p.4-21