4RF Aprisa SR+ User Manual - page 202
Manual is about: Smart, secure, industry-leading speed licensed point-to-multipoint SCADA communications for industrial monitoring and control
of
403
200 | Managing the Radio
Aprisa SR+ User Manual 1.5.3
Maintenance > Modem
Base Station
FEC DISABLE
FEC Disable
This parameter sets whether the Forward Error Correction can be disabled.
Option
Function
Enable
Enables the FEC Disable diagnostic function
Disable
Disables the FEC Disable diagnostic function
Timer
Allows the FEC to be disabled but only for a predetermined period.
Duration (s)
This parameter defines the period required for disabling of the FEC. When this period elapses, the FEC is
enabled.