C-Nav 2050M User Manual - page 51
of
166
C-Nav2050 User Guide
LEMO plug, type FGG.0K.305.CLAC50Z, plus strain
relief, (P/N: 4250007-3).
1 PPS
A pulse is available from the C-Nav2050M at an output
rate of once per second. This pulse can be used for a
variety of Time/ Mark applications where relative timing
is required.
Specifications:
12.5ns relative accuracy
Better than 100ns absolute accuracy
50 Ohm, TTL level
Pulse width, default 100mS, range 10 – 999mS
Pulse delay, default 0mS, range 0 – 999mS
Rising or Falling Edge Synchronization
A BNC female connector provides the 1PPS output
pulse. A 3ft (0.9m) long, BNC male to BNC male cable
(P/N: 4250006-3) is available by contacting C-Nav
Support.
Figure 10: C-Nav2050M Back View
2-9