Figure 7 - 44. Access Rule Table (Ethernet)
To remove a previously created rule, select it and click the
button. To add a new Access Rule, click the Add button:
Figure 7 - 45. Access Rule Configuration window (Ethernet)
To set the Access Rule for Ethernet, adjust the following parameters and click Apply.
Parameter
Description
Profile ID
This is the identifier number for this
profile set.
Access ID
Type in a unique identifier number for
this access. This value can be set from 1
- 50.
Mode
Select Permit to specify that the packets
that match the access profile are
forwarded by the Switch, according to
any additional rule added (see below).
Select Deny to specify that packets that
do not match the access profile are not
forwarded by the Switch and will be
filtered.
Priority(0-7)
This parameter is specified if you want to
re-write the 802.1p default priority
previously set in the Switch, which is
used to determine the CoS queue to
which packets are forwarded to. Once
this field is specified, packets accepted
by the Switch that match this priority are
forwarded to the CoS queue specified
previously by the user.