21-6
TROUBLESHOOTING
INSPECTION
CAUSE OF TROUBLE
Fuse cut.
Battery weak or totally discharged.
Ignition switch damaged or shorted.
Terminal loose of faulty connection.
Wire harness damaged.
Faulty fuel level sensor connection.
Damper oil inside the meter
insufficient.
Faulty connection between the
sliding arm and the resistance.
Terminal connection loose or faulty
connection.
Balance coil/lead shorted or
damaged.
GAUGE NEEDLE SHAKES OR VERTICALLY WOBBLES. (IGNITION SWTICH ON)
1. Operate the turn signal to check the
battery circuit.
2. Remove the tank and operate the
float.
3. Move the float rapidly. One
up/down motion per second.
4. Start the engine, and measure the
fuel level sensor resistance.
5. Check each joint.
Signal continuously
operates dim or does not
operate at all.
Needle not moving.
Needle not moving.
Resistance changed
significantly.
Unsatisfactory
Signal operates satisfactorily.
Satisfactory
Needle moving.
Needle moving.
Resistance not changed.