EZ Call a Matic User Manual - page 47
(a) ENABLE Toll control (press YES / NO key till the display shows ENABLE)
(b) Set the dialing speed = 1
(c) Select the phone type = MITEL SX200 LITE (press the NO key until the screen
displays MITEL SX200 LITE)
(d) Choose the Baud rate and Communication specifications (change any field by
pressing NO and to select any field press YES or ENTER. Select ACK/ NAK required.
(e) The next screen prompts you to select SX200 TYPE A or TYPE B. If the Type A
option is chosen, when there is a Credit violation for a Guest room, the Call-A-Matic dials
out the Check Out String to the PBX (this prevents the Guest making any more calls and
also clears the Wake up calls set for that room). In the Type B option, in the above case, the
Check In string is dialed out (this brings the room phone to the default restriction level and
retains the Wake up calls set for that room).
3.
Programming the SX200 LITE.
(a) Select the COS number
(b) Form 04 System options : Program the Following
System options/ Timers
Status
35. Property Management System
ENABLE
27. Room Status Audit
DISABLE
33. Room Status
DISABLE
(c) Enable the following COS options
901 – DTRX Herald.
904 – DTRX Complete Message Text.
906 – Data SMDR does not apply.
(d) Form 29 DTE Profile
—Select a DTE profile number. You will use this profile number in Form12–Data Assignment
—Select the SEL option Subform
—Enable the DTRX Echoplex, Editing and edit Character = 127
(e) Form 11 Data Circuit Descriptor
—Select a Circuit Descriptor (CDN). You will use this CDN in form 12 in the Next step.
Option Name
Value
Session inactivity timer
0
Guard timer
2
Minimum Baud Rate
MATCH CALL-A-MATIC
Default Baud Rate
MATCH CALL-A-MATIC
Maximum Baud Rate
MATCH CALL-A-MATIC
Always use Default Baud rate
Yes
DTR off Disconnect timer
5
DTR to CTS Delay timer
100
DTR Forced High
YES
RTS Forced High
YES
DSR is held high when device idle
YES
Originate a DTRX call with Low high transition of DTR
NO
Action taken if the Idle DTE has DTR low ( Auto answer)
Refuse
ASYNC: Keyboard origination allowed
DISABLE
ASYNC: ADL auto Baud
DISABLE
ASYNC : Flow control
XON/ XOFF
ASYNC : Parity
MATCH CALL-A-MATIC
ASYNC: Character length
MATCH CALL-A-MATIC
ASYNC: Number of Stop Bits
MATCH CALL-A-MATIC
DS2100: operating mode
ASYNCHRONOUS
CallAMatic