NEC Univerge SV8100 System Hardware Manual

Other manuals for Univerge SV8100: Service Information Bulletin, Description, User Manual, User Manual, Quick Start User Manual, User Manual, Information Sheet, User Manual, System Specifications, Configuration Manual, User Manual, User Manual, Quick Reference Manual, Quick Reference Manual, Programming Manual, General Description Manual, User Manual, System Maintenance Manual, User Manual, Features And Specifications Manual, Quick Manual, Features And Specifications Manual, Features And Specifications Manual, Features And Specifications Manual, Features And Specifications Manual, Features And Specifications Manual, Features And Specifications Manual, User Manual, Installation Manual, Installation Manual, Reference Manual, User Manual, System Hardware Manual, Reference sheet, Reference Sheet, Quick Start & Reference Manual, System Configuration Manual, User Manual, User Manual, Programming Manual, Administrator's Manual, User Manual, Quick Reference Manual, Quick Reference Manual, User Manual, User Manual, System Hardware Manual, Installation Manual, Condensed User's Manual, Installation Manual, Quick Reference Manual, System Hardware Manual, User Manual, Installation Manual, Administration Manual, Quick Reference Manual, System Hardware Manual, Features & Specifications Manual, Adminstrators Manual, System Hardware Manual, Programming Manual, Applications, User Manual, Installation Manual, Reference Sheet

Summary of Univerge SV8100

  • Page 1

    System hardware manual issue 7.0 november 2012.

  • Page 2

    This page intentionally left blank.

  • Page 3: Regulatory

    System hardware manual i ___________________________________________________________________________________ ___________________________________________________________________________________ table of contents regulatory chapter 1 introduction to sv8100 section 1 general information ..................

  • Page 4

    Issue 7.0 univerge sv8100 ___________________________________________________________________________________ ii table of contents ___________________________________________________________________________________ 5.5.1 transmission .....................................................................

  • Page 5

    Univerge sv8100 issue 7.0 system hardware manual - iii ___________________________________________________________________________________ ___________________________________________________________________________________ system hardware manual iii __________________________________________________...

  • Page 6

    Issue 7.0 univerge sv8100 ___________________________________________________________________________________ iv table of contents ___________________________________________________________________________________ 2.8.2 install additional blades 9.5” chassis ......................................3-...

  • Page 7

    Univerge sv8100 issue 7.0 system hardware manual - v ___________________________________________________________________________________ ___________________________________________________________________________________ system hardware manual v ______________________________________________________...

  • Page 8

    Issue 7.0 univerge sv8100 ___________________________________________________________________________________ vi table of contents ___________________________________________________________________________________ 3.3.1 description ......................................................................

  • Page 9

    Univerge sv8100 issue 7.0 system hardware manual - vii ___________________________________________________________________________________ ___________________________________________________________________________________ system hardware manual vii __________________________________________________...

  • Page 10

    Issue 7.0 univerge sv8100 ___________________________________________________________________________________ viii table of contents ___________________________________________________________________________________ 5.1.1 description ....................................................................

  • Page 11

    Univerge sv8100 issue 7.0 system hardware manual - ix ___________________________________________________________________________________ ___________________________________________________________________________________ system hardware manual ix ____________________________________________________...

  • Page 12: Multiline Terminals

    Issue 7.0 univerge sv8100 ___________________________________________________________________________________ x table of contents ___________________________________________________________________________________ 6.3.2 installation ......................................................................

  • Page 13

    Univerge sv8100 issue 7.0 system hardware manual - xi ___________________________________________________________________________________ ___________________________________________________________________________________ system hardware manual xi ____________________________________________________...

  • Page 14

    Issue 7.0 univerge sv8100 ___________________________________________________________________________________ xii table of contents ___________________________________________________________________________________ 4.10 wall mounting the multiline terminal .........................................5...

  • Page 15

    Univerge sv8100 issue 7.0 system hardware manual - xiii ___________________________________________________________________________________ ___________________________________________________________________________________ system hardware manual xiii ________________________________________________...

  • Page 16

    Issue 7.0 univerge sv8100 ___________________________________________________________________________________ xiv table of contents ___________________________________________________________________________________ section 10 d term ® cordless dect (dtl-8r-1) ..........................................

  • Page 17

    Univerge sv8100 issue 7.0 system hardware manual - xv ___________________________________________________________________________________ ___________________________________________________________________________________ system hardware manual xv ____________________________________________________...

  • Page 18

    Issue 7.0 univerge sv8100 ___________________________________________________________________________________ xvi table of contents ___________________________________________________________________________________ 9.1 night mode selector switch ........................................................

  • Page 19

    Univerge sv8100 issue 7.0 system hardware manual - xvii ___________________________________________________________________________________ ___________________________________________________________________________________ system hardware manual xvii ________________________________________________...

  • Page 20

    Issue 7.0 univerge sv8100 ___________________________________________________________________________________ xviii table of contents ___________________________________________________________________________________.

  • Page 21: Regulatory

    System hardware manual r-1 battery disposal the univerge sv8100 system includes the batteries listed below. When disposing of these batteries, chassis, and/or blades, you must comply with applicable regulations regarding proper disposal procedures. The univerge sv8100 cd-cp00 provides memory backup ...

  • Page 22

    Issue 7.0 univerge sv8100 r-2 regulatory the incineration, landfilling or mixing of nickel-cadmium or sealed lead batteries with the municipal solid waste stream is prohibited by law in most areas. Contact your local solid waste management officials for other information regarding the environmentall...

  • Page 23

    Univerge sv8100 issue 7.0 system hardware manual r-3 european union information notice to the user the system described in this manual is intended to be connected to analog and digital networks and supports a wide range of peripheral equipment. The following interfaces are available for connection t...

  • Page 24

    Issue 7.0 univerge sv8100 r-4 regulatory product disposal information for countries in the european union the symbol depicted here has been affixed to your product in order to inform you that electrical and electronic products should not be disposed of as municipal waste. Electrical and electronic p...

  • Page 25: Introduction to Sv8100

    System hardware manual 1 - 1 chapter 1 introduction to sv8100 s ection 1 g eneral i nformation the sv8100 is a full-featured ip based communications system providing a rich feature set of existing system, with pure voice over ip (voip) communications, across corporate local and wide area networks (l...

  • Page 26

    Issue 7.0 univerge sv8100 1 - 2 introduction to sv8100 highlights of the univerge sv8100 are as follows: z pure ip system capable tdm configuration the sv8100 supports both pure ip switching (peer-to-peer connections) and time division switching. The pure ip switching is provided for communications ...

  • Page 27

    Univerge sv8100 issue 7.0 system hardware manual 1 - 3 mf senders / receivers 10/100 ethernet port 2 control relays moh input port paging output port in-mail (vmdb) voip. In addition, by means of advanced lsi technology, size of the cpu blade is minimized, o&m nic port (10/100m) is built in and voip...

  • Page 28

    Issue 7.0 univerge sv8100 1 - 4 introduction to sv8100 s ection 2 e quipment l ist the following tables list all equipment for the sv8100 systems. Table 1-1 chassis equipment list equipment name equipment description product code chs2u 19” chassis (6-slot) sv8100 chs2u gw 9.5” chassis (3-slot) sv810...

  • Page 29

    Univerge sv8100 issue 7.0 system hardware manual 1 - 5 table 1-4 blade equipment list equipment name abbreviations equipment description product code cd-cp00 cpu main processor blade for kts sv8100 pz-bs10 bus0 expansion chassis interface unit, 3-jack sv8100 pz-bs11 bus1 expansion chassis interface ...

  • Page 30

    Issue 7.0 univerge sv8100 1 - 6 introduction to sv8100 table 1-5 cable equipment list equipment name equipment description product code rs console ca-a mat (pcpro) cable 6.6 ft. (2.0m) sv8100 rs norm-4s ca-f rs-232c cable (normal) 13.1 ft (4m) sv8100 rs rvs-15s ca-f rs-232c cable (reverse) 49.2 ft (...

  • Page 31

    Univerge sv8100 issue 7.0 system hardware manual 1 - 7 8lk-l (bk) unit 8lk-l (wh) unit 8-button line key unit sv8100 8lkd (ld)-l (bk) unit 8lkd (ld)-l (wh) unit desi-less 8-button line key unit/lcd unit for digital telephone sv8100 lcd (bl)-l (bk) unit lcd (bl)-l (wh) unit lcd unit (backloght lcd) f...

  • Page 32

    Issue 7.0 univerge sv8100 1 - 8 introduction to sv8100 psa-l (bk) unit psa-l (wh) unit psa sv8100 bch-l (bk) unit bluetooth cordless handset sv8100 12lk-l (bk) kit 12lk-l (wh) kit 12-button line key kit sv8100 lcd (bl)-l (bk) unit lcd (bl)-l (wh) unit lcd unit (no backlight) sv8100 wm-l unit wall mo...

  • Page 33

    Univerge sv8100 issue 7.0 system hardware manual 1 - 9 panel (silver-base)-l unit color side panel for base (silver) sv8100 panel (silver-vlcd)-l unit color side panel for value telephone lcd (silver) sv8100 panel (silver-slcd)-l unit color side panel for sophisticated telephone lcd (silver) sv8100 ...

  • Page 34

    Issue 7.0 univerge sv8100 1 - 10 introduction to sv8100 12lksoft-l (bk) set 12lksoft-l (wh) set 12lk without soft key sv8100 12lk(std)-l (bk) set 12lk(std)-l (wh) set 12lk sv8100 tkpanel(std)-l (bk) unit tkpanel(std)-l (wh) unit 10-key panel sv8100 cradle (std)-l(bk) cradle (std)-l(wh) cradle sv8100...

  • Page 35

    Univerge sv8100 issue 7.0 system hardware manual 1 - 11 keykitpanel(v)-l (d-brown-m) unit color face panel for value (dark brown metallic) 1 set consists 10 of panels sv8100 lkpanel(12btn)-l (m-blue) unit color lk panel (12button) for value( metallic blue) 1 set consists 10 of panels sv8100 lkpanel(...

  • Page 36

    Issue 7.0 univerge sv8100 1 - 12 introduction to sv8100 panel(c gold-slcd)-l unit color side panel for sophi lcd (champagne gold) 1 set consist of 10 pair of panels. A pair includes (1) left and (1) right panel sv8100 panel(bio-base)-l unit bio side panel for base 1 set consist of 10 pair of panels....

  • Page 37

    Univerge sv8100 issue 7.0 system hardware manual 1 - 13 handsetcord(25ft)-l (bk) set handsetcord(25ft)-l (wh) set spare handset cord 25 feet sv8100 handsethanger-l (bk) set handsethanger-l (wh) set spare handset hanger sv8100 itl (value)-base-1 unit ip base sv8100 lcdi(s)-l (bk) unit lcdi(s)-l (wh))...

  • Page 38

    Issue 7.0 univerge sv8100 1 - 14 introduction to sv8100

  • Page 39: Sv8100 System Specifications

    System hardware manual 2 - 1 chapter 2 sv8100 system specifications s ection 1 g eneral i nformation this chapter provides detailed specifications for the sv8100 system technician. The technician should review this information carefully before installing the system. S ection 2 s ystem b lock d iagra...

  • Page 40

    Issue 7.0 univerge sv8100 2 - 2 sv8100 system specifications cnf conference bridge blade (pva) cpu central processing unit did direct inward dialing diop did/opx blade dlc digital multiline terminal interface blade dlcb expansion digital multiline terminal interface blade on dlc drs device registrat...

  • Page 41

    Univerge sv8100 issue 7.0 system hardware manual 2 - 3 pft power failure transfer plo phase locked oscillator (on cpu) pms property management system pri primary rate interface prt primary rate interface blade ps personal station psa pstn adapter (analog) pva packet voice application rtb router blad...

  • Page 42

    Issue 7.0 univerge sv8100 2 - 4 sv8100 system specifications figure 2-1 sv8100 system block diagram.

  • Page 43

    Univerge sv8100 issue 7.0 system hardware manual 2 - 5 s ection 3 m aximum s ystem c apacities the chs2u is a compact 19” chassis that has six universal slots, one expansion slot and one mps7101 (power supply unit). When the cd-cp00 is installed in the first chs2u, it is referred to as the controlli...

  • Page 44

    Issue 7.0 univerge sv8100 2 - 6 sv8100 system specifications 3.1 system configuration – sv8100 the 9.5” chassis provides 48 total ports (32 digital terminals) and can include any combination of stations and trunks below this number. Please note: the 9.5” chassis cannot be expanded. The sv8100 19” ch...

  • Page 45

    Univerge sv8100 issue 7.0 system hardware manual 2 - 7 figure 2-3 19” controlling and expansion chassis 6 slots 18 slots ip connection 24 slots the 9.5” chassis graphics shown in the horizontal position are for illustration purposes only. Actual positioning/ mounting must be vertical..

  • Page 46

    Issue 7.0 univerge sv8100 2 - 8 sv8100 system specifications table 2-3 maximum system capacities – chassis shows the maximum number of chassis and related equipment that can be installed in a system. Table 2-3 maximum system capacities – chassis hardware 19” chassis with cpu 19” chassis without cpu ...

  • Page 47

    Univerge sv8100 issue 7.0 system hardware manual 2 - 9 table 2-4 maximum system capacities – blades shows the maximum number for each blade that can be installed in a system. This is determined by the maximum blade configuration allowed. When installing single line sets, disa, or tie lines, cpu circ...

  • Page 48

    Issue 7.0 univerge sv8100 2 - 10 sv8100 system specifications cd-4lca (4 single line telephone interface) 2 5 6 23 – pz-4lca (4 single line telephone interface daughter board) 2 5 6 23 – cd-8dlca (8 digital station interface) 2 5 6 23 pz-8dlcb (8 digital station interface daughter board) 2 5 6 23 cd...

  • Page 49

    Univerge sv8100 issue 7.0 system hardware manual 2 - 11 cd-4diopb (4 did/opx) 1 5 6 23 when installed as a did blade cd-4odta (4 e&m) 2 5 6 23 – cd-prta (1 primary rate interface) 2 3 3 6 this blade is used for primary rate interface. Optional blades: cd-pvaa (conference bridge) 2 5 6 23 r2 cd-etia ...

  • Page 50

    Issue 7.0 univerge sv8100 2 - 12 sv8100 system specifications table 2-5 daughter board combinations shows each blade and associated daughter board combinations. The daughter boards that can be mounted on specific blades are indicated by a checkmark. For example, the cd-lta can have a pz-2bria or the...

  • Page 51

    Univerge sv8100 issue 7.0 system hardware manual 2 - 13 s ection 4 p ower -b ased c alculator c hart the univerge sv8100 system uses two types of power factors. For a single chassis chart refer to table 2-6 board power factor . For the maximum number of specific blades per package, see table 2-7 max...

  • Page 52

    Issue 7.0 univerge sv8100 2 - 14 sv8100 system specifications table 2-8 terminal power factor terminal power factor 19 inch chassis = item power factor dtl-24d-1 tel 0.8 dtl-8ld-1 tel 0.8 bha-l unit 2 ada-l unit 2 apr unit 2 bch-l (bk) unit 2 psa-l( ) 1.2 8lk-l unit 0 dcl-60-1 console 2 itl-320c-1 t...

  • Page 53

    Univerge sv8100 issue 7.0 system hardware manual 2 - 15 table 2-9 ip terminal power chart ip terminal ieee802. 3af class label indication (maximum current with all options) maximum current without options 48vdc 24vdc 48vdc 24vdc itl-12cg-3 tel class 3 230ma 11.04w 450ma 10.8w 102ma 4.9w 192ma 4.62w ...

  • Page 54

    Issue 7.0 univerge sv8100 2 - 16 sv8100 system specifications table 2-11 tdm terminal power chart tdm terminal power consumption dtl-2e-1 1.0w dtl-6de-1 1.1w dtl-8ld-1 2.2w dtl-12d-1 2.0w dtl-24d-1 2.0w dtl-32d-1 2.4w.

  • Page 55

    Univerge sv8100 issue 7.0 system hardware manual 2 - 17 s ection 5 s ystem r equirements and s pecifications 5.1 cabling this section provides cabling requirements and specifications for various equipment used in the sv8100 system. Figure 2-4 connecting the dlc using twisted 2-pair cable is a diagra...

  • Page 56

    Issue 7.0 univerge sv8100 2 - 18 sv8100 system specifications dtl-24d-1(bk) tel dtl-24d-1(wh) tel 1,969 ft (600m) 6,562 ft (2000m) dtl-32d-1 (bk) tel dtl-32d-1 (wh) tel 1,969 ft (600m) 6,562 ft (2000m) dcl-60-1 console * - 1,969 ft (600m) * an ac adapter is required. Table 2-13 dt700 series loop res...

  • Page 57

    Univerge sv8100 issue 7.0 system hardware manual 2 - 19 table 2-14 d term series i or d term ip terminal loop resistance and cable length terminal or adapter maximum loop resistance (without ac adapter) (ohms) by twisted 1-pair cable (without ac adapter) 24 awg by twisted 2-pair cable (without ac ad...

  • Page 58

    Issue 7.0 univerge sv8100 2 - 20 sv8100 system specifications 5.2 power requirements a dedicated 100vac/120vac/220vac/230-240vac 50hz/60hz circuit located within seven feet of the chassis is required. A separate dedicated outlet for each chassis should be installed. 5.2.1 power supply specifications...

  • Page 59

    Univerge sv8100 issue 7.0 system hardware manual 2 - 21 va @ 230v: base chassis= 276va , expansion chassis= 276va , total 1104va kwh @ ac input i x 230v/1000: base chassis=0.276 kwh, expansion chassis=0.276 kwh, total 1.104 kwh btu (kwh x 3413): base chassis= 942 btu , expansion chassis= 942 btu , t...

  • Page 60

    Issue 7.0 univerge sv8100 2 - 22 sv8100 system specifications recommended long term humidity: 10 ~ 90% rh blades - cd-4lca , pz-4lca , cd-8lca , pz-8lce , cd-4cota , pz-4cote , cd-prta operating temperature: 0°c ~ 40°c recommended long term temperature: -20°c ~ 60°c operating humidity: 10 ~ 90% rh (...

  • Page 61

    Univerge sv8100 issue 7.0 system hardware manual 2 - 23 5.5.2 network time division multiplexing (tdm) allows transmission of data and voice simultaneously over one communications medium. The specifications that the univerge sv8100 system uses for switching, clock, data bus, and timeframe are shown ...

  • Page 62

    Issue 7.0 univerge sv8100 2 - 24 sv8100 system specifications 5.5.4 electra elite ipk terminals and equipment the voltage, current, and ring signal for the electra elite ipk multiline terminals, single line telephone equipment, and ap(a)-r/ap(r)-r units are listed below: multiline terminal voltage: ...

  • Page 63

    Univerge sv8100 issue 7.0 system hardware manual 2 - 25 5.5.5 series i terminals the voltage and current for the d term series i multiline terminals are listed below: voltage: -11 ~ -48 vdc maximum current: 250 ma voltage, current, and ring signal information for single line telephone equipment, ap(...

  • Page 64

    Issue 7.0 univerge sv8100 2 - 26 sv8100 system specifications rise time: within 5 ms. Duration of dual frequency signal: 110 ms. Default/60 ms. Minimum interdigital time: 140 ms. Default/45 ms. Minimum 5.6.3 external equipment connection door phone or tv door phone external speaker via amplifier ext...

  • Page 65

    Univerge sv8100 issue 7.0 system hardware manual 2 - 27 5.6.7 external tone ringer/night chime output output level: –10 dbm output impedance: 600 Ω relay contact rating: 500 ma, 24 vdc 5.6.8 smdr output female connector (lan) standard db-9 (straight) 5.6.9 pc connection female connector (lan) standa...

  • Page 66

    Issue 7.0 univerge sv8100 2 - 28 sv8100 system specifications 5.8 weights and dimensions table 2-18 sv8100 weights and dimensions on page 2-28 shows the shipping weight, height, width and depth of each sv8100 digital multiline terminal, ip multiline terminal, d term , series i multiline terminal, ch...

  • Page 67

    Univerge sv8100 issue 7.0 system hardware manual 2 - 29 cd-8dlca 5.89 oz (0.167 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.09 in (180 mm) pz-8dlcb 4.41 oz (0.125 kg) 0.60 in (15 mm) 4.72 in (120 mm) 5.12 in (130 mm) cd-16dlca 7.831 oz (0.222 kg) 1.89 in (48 mm) 9.45 in (240 mm) 7.68 in (195 mm) cd-4cota...

  • Page 68

    Issue 7.0 univerge sv8100 2 - 30 sv8100 system specifications chs base unit 21.87 oz (0.62 kg) 23.23 in (590 mm) 17.72 in (450 mm) 10.43 in (265 mm) chs2u blank slot cover kit 1.76 oz (0.05 kg) 2.32 in (60 mm) 1.57 in (40 mm) 1.57 in (40 mm) chs l batt box rack mount bracket 352.7 oz (10 kg) 18.5 in...

  • Page 69

    Univerge sv8100 issue 7.0 system hardware manual 2 - 31 itl-6de-1 (bk) tel 38.8 oz (1.1 kg) 4.41 in (112 mm) 7.05 in (179 mm) 8.86 in (225 mm) itl-8lde-1 (bk) tel 63.66 oz (1.98 kg) 4.41 in (112 mm) 7.05 in (179 mm) 8.86 in (225 mm) itl-8ld-1 (bk) tel itl-8ld-1 (wh) tel 45.6 oz (1.3 kg) 4.41 in (112...

  • Page 70

    Issue 7.0 univerge sv8100 2 - 32 sv8100 system specifications dcl-60-1 (bk) console dcl-60-1 (wh) console 21.16 oz (.6 kg) 3.23 in (82 mm) 5.39 in (137 mm) 8.82 in (224 mm) psa-l (bk) unit psa-l (wh) unit 10.58 oz (0.3 kg) 3.15 in (80 mm) 2.91 in (74 mm) 8.8 in (223 mm) gba-l unit 23.99 ox (0.68 kg)...

  • Page 71

    System hardware manual 3 - 1 chapter 3 installing the sv8100 chassis s ection 1 g eneral i nformation this chapter contains information to help the technician install the chassis for the sv8100 system. The technician should be familiar with this section before installing any equipment. S ection 2 i ...

  • Page 72

    Issue 7.0 univerge sv8100 3 - 2 installing the sv8100 chassis figure 3-1 chs2u chassis (front view) figure 3-2 chs2u chassis (rear view) universal slot for legacy line/trunk blades and application blades (six slots). When used as controlling chassis, the cd-cp00 is mounted in slot 1 (shown). Slot fo...

  • Page 73

    Univerge sv8100 issue 7.0 system hardware manual 3 - 3 the chs2u gw chassis has three universal blade slots for station, trunk and optional blades.The chassis can be wall-mounted or stand-mounted. The first part of the this chapter describes the differing types of mounting options and the rest of th...

  • Page 74

    Issue 7.0 univerge sv8100 3 - 4 installing the sv8100 chassis 2.1 wall mounting the 19” chassis when wall mounting the chassis, ensure the wall can support the weight of the chassis (55 lbs per system chassis ---- including blades, cords, power supply, etc.). The chassis is secured to the wall with ...

  • Page 75

    Univerge sv8100 issue 7.0 system hardware manual 3 - 5 2. Mark and drill the six holes required for a wall installation. 3. Align screw holes in wall mount brackets with drilled holes..

  • Page 76

    Issue 7.0 univerge sv8100 3 - 6 installing the sv8100 chassis 4. Using six screws, secure the two wall mount brackets to the wall. Refer to figure 3-6 install wall mount brackets with screws for screw location. 5. Using four screws, secure the metal fittings on the left and right sides of the 19” ch...

  • Page 77

    Univerge sv8100 issue 7.0 system hardware manual 3 - 7 figure 3-7 install wall mount brackets with screws.

  • Page 78

    Issue 7.0 univerge sv8100 3 - 8 installing the sv8100 chassis 6. Align the metal fitting with the upper wall mount bracket. The lower metal fitting rests against the lower wall mount bracket. Secure the metal fitting and upper wall mount bracket with a single screw (see figure 3-8 secure metal fitti...

  • Page 79

    Univerge sv8100 issue 7.0 system hardware manual 3 - 9 8. Attach the supplied cable support bracket to either end of the lower wall mount bracket with a single screw (refer to figure 3-10 attach cable support bracket with screw on page 3-10 ). Figure 3-9 secure metal fitting to lower wall mount brac...

  • Page 80

    Issue 7.0 univerge sv8100 3 - 10 installing the sv8100 chassis 9. The cable support bracket can be installed any of the four corners of the 19” chassis (refer to figure 3-11 attach cable support bracket with screw on page 3-11 ). Figure 3-10 attach cable support bracket with screw.

  • Page 81

    Univerge sv8100 issue 7.0 system hardware manual 3 - 11 10. Connect the ground wire to all chassis. Refer to 2.7.5 install 19” chassis grounding on page 3-52 for complete details on grounding the system. 11. Refer to 2.7 installing the 19” chassis on page 3-39 to continue installation of the chassis...

  • Page 82

    Issue 7.0 univerge sv8100 3 - 12 installing the sv8100 chassis 2.2 floor mounting the 19” chassis the chs2u controlling and expansion chassis can be mounted on the floor using the chs base unit and the chs2u joint bracket kit. 2.2.1 chs2u chassis installation 1. Use the template shown in figure 3-12...

  • Page 83

    Univerge sv8100 issue 7.0 system hardware manual 3 - 13 . 4. Install the five rubber feet to the bottom of the chassis. 5. Position the chassis on top of the chs base unit. 6. Secure the chassis to the chs base unit using eight screws supplied with the chs2u joint bracket kit. Figure 3-13 secure chs...

  • Page 84

    Issue 7.0 univerge sv8100 3 - 14 installing the sv8100 chassis 7. Connect the ground wire to all chassis. Refer to 2.7.5 install 19” chassis grounding on page 3-52 for complete details on grounding the system. 8. Refer to 2.7 installing the 19” chassis on page 3-39 to continue installation of the ch...

  • Page 85

    Univerge sv8100 issue 7.0 system hardware manual 3 - 15 1. Install the five rubber feet to the bottom of each chassis. 2. Using supplied screws in the chs2u joint bracket kit, attach metal brackets to both ends of the 19” chassis and the chs base unit. Refer to figure 3-17 install metal brackets wit...

  • Page 86

    Issue 7.0 univerge sv8100 3 - 16 installing the sv8100 chassis 3. Connect the ground wire to all chassis. Refer to 2.7.5 install 19” chassis grounding on page 3-52 for complete details on grounding the system. 4. Refer to 2.7 installing the 19” chassis on page 3-39 to continue installation of the ch...

  • Page 87

    Univerge sv8100 issue 7.0 system hardware manual 3 - 17 3. Using supplied screws, secure the chs2u stand kit to the floor (refer to figure 3-20 secure stand mount to floor with screws on page 3-18 ). Figure 3-19 secure chs2u chassis to chs2u stand kit with screws expansion plate.

  • Page 88

    Issue 7.0 univerge sv8100 3 - 18 installing the sv8100 chassis 4. Connect the ground wire to all chassis. Refer to 2.7.5 install 19” chassis grounding on page 3-52 for complete details on grounding the system. 5. Refer to 2.7 installing the 19” chassis on page 3-39 to continue installation of the ch...

  • Page 89

    Univerge sv8100 issue 7.0 system hardware manual 3 - 19 2.3.2 multiple chs2u chassis installation expansion chassis (maximum of three) can be added to the chs2u stand kit and will require an additional chs2u stand kit (ext) per chassis. 1. Install the five rubber feet to the bottom of each chassis. ...

  • Page 90

    Issue 7.0 univerge sv8100 3 - 20 installing the sv8100 chassis 3. Metal brackets from the chs2u joint bracket kits will be required to secure the top end of the chassis with screws. See figure 3-23 install additional chs2u stand kit (ext) on page 3-21 . Figure 3-22 install additional chs2u stand kit...

  • Page 91

    Univerge sv8100 issue 7.0 system hardware manual 3 - 21 4. Using supplied screws, secure the chs2u stand kit to the floor (refer to figure 3-23 install additional chs2u stand kit (ext) on page 3-21 ). 5. Connect the ground wire to all chassis. Refer to 2.7.5 install 19” chassis grounding on page 3-5...

  • Page 92

    Issue 7.0 univerge sv8100 3 - 22 installing the sv8100 chassis 2.4 rack mounting the 19” chassis a single or multiple chassis can be rack mounted. Controlling and expansion chassis can be racked mounted by stacking them horizontally. 1. The 19” chassis requires two rack mount brackets per chassis fo...

  • Page 93

    Univerge sv8100 issue 7.0 system hardware manual 3 - 23 repeat for additional chassis mounting. 4. Carefully slide the chassis into desired location in the rack. Make sure the hooks on the mounting bracket are inserted into the back of the chassis, securing it in place. Note that the cabling is run ...

  • Page 94

    Issue 7.0 univerge sv8100 3 - 24 installing the sv8100 chassis 6. Connect the ground wire to all chassis. Refer to 2.7.5 install 19” chassis grounding on page 3-52 for complete details on grounding the system. 7. Refer to 2.7 installing the 19” chassis on page 3-39 to continue installation of the ch...

  • Page 95

    Univerge sv8100 issue 7.0 system hardware manual 3 - 25 2.5.1 option 1 1. Use the template shown in figure 3-28 wall mount spacing guide (9.5” chassis) on page 3-25 for required spacing before drilling. 2. Mark and drill four holes 3. Align the bracket halves with the precut holes in the metal expan...

  • Page 96

    Issue 7.0 univerge sv8100 3 - 26 installing the sv8100 chassis 4. Secure the bracket halves to the expansion fitting using the four supplied screws (refer to figure 3-29 9.5” mounting brackets and metal expansion fitting on page 3-26 ). 5. Turn bracket assembly over and remove the screws holding two...

  • Page 97

    Univerge sv8100 issue 7.0 system hardware manual 3 - 27 brackets secured in mounting position with screws ). 6. Rotate the brackets into the mounting position. Using the same screws, secure the metal brackets to the bracket assembly (refer to figure 3-30 brackets secured in mounting position with sc...

  • Page 98

    Issue 7.0 univerge sv8100 3 - 28 installing the sv8100 chassis 8. Using four screws, secure bracket assembly to the four pre-drilled holes in the wall. 9. Fit the precut holes on the 9.5” chassis over the metal tabs (refer to figure 3-32 attach 9.5” chassis to wall mounting bracket on page 3-29 ). F...

  • Page 99

    Univerge sv8100 issue 7.0 system hardware manual 3 - 29 10. Using the screws removed earlier, install the end brackets to secure the 9.5” chassis to the mounted bracket assembly. 11. Connect grounding wire to chassis. Refer to 2.8 installing the 9.5” chassis on page 3-54 for complete details on grou...

  • Page 100

    Issue 7.0 univerge sv8100 3 - 30 installing the sv8100 chassis 12. Refer to 2.8 installing the 9.5” chassis on page 3-54 to continue installation of the chassis or 2.2 installing an extension or trunk blade on page 4-4 for installation of blades. 2.5.2 option 2 1. Use the template shown in figure 3-...

  • Page 101

    Univerge sv8100 issue 7.0 system hardware manual 3 - 31 figure 3-34 install screws (option 2).

  • Page 102

    Issue 7.0 univerge sv8100 3 - 32 installing the sv8100 chassis 4. Align the bracket halves with the precut holes in the metal expansion fitting provided (refer to figure 3-35 9.5” mounting brackets and metal expansion fitting ). 5. Secure the bracket halves to the expansion fitting using the four su...

  • Page 103

    Univerge sv8100 issue 7.0 system hardware manual 3 - 33 two brackets in the shipped position (refer to figure 3-36 brackets secured in mounting position with screws ). 7. Rotate the brackets into the mounting position. Using the same screws, secure the metal brackets to the bracket assembly (refer t...

  • Page 104

    Issue 7.0 univerge sv8100 3 - 34 installing the sv8100 chassis 9. Fit the precut holes on the 9.5” chassis over the metal tabs (refer to figure 3-38 attach 9.5” chassis to wall mounting bracket on page 3-35 ). Figure 3-37 remove end brackets.

  • Page 105

    Univerge sv8100 issue 7.0 system hardware manual 3 - 35 10. Using the screws removed earlier, install the end brackets to secure the 9.5” chassis to the mounted bracket assembly. Figure 3-38 attach 9.5” chassis to wall mounting bracket figure 3-39 install end brackets.

  • Page 106

    Issue 7.0 univerge sv8100 3 - 36 installing the sv8100 chassis 11. Using the key-holes as a guide, slide the assembled unit over the screws previously installed in the wall (refer to figure 3-34 install screws (option 2) on page 3-31 ). 12. Connect grounding wire to chassis. Refer to 2.8 installing ...

  • Page 107

    Univerge sv8100 issue 7.0 system hardware manual 3 - 37 figure 3-41 attach 9.5” stand mount bracket figure 3-42 attach remaining 9.5” stand mount bracket.

  • Page 108

    Issue 7.0 univerge sv8100 3 - 38 installing the sv8100 chassis 3. With brackets snug against the 9.5” chassis, carefully slide the brackets in opposite directions (refer to arrows figure 3-43 stand mount brackets installed ), until they snap into place. 4. Secure the 9.5” assembly to a flat surface ...

  • Page 109

    Univerge sv8100 issue 7.0 system hardware manual 3 - 39 5. Connect grounding wire to chassis. Refer to 2.8 installing the 9.5” chassis on page 3-54 for complete details on grounding the system. 6. Refer to 2.8 installing the 9.5” chassis on page 3-54 to continue installation of the chassis or, chapt...

  • Page 110

    Issue 7.0 univerge sv8100 3 - 40 installing the sv8100 chassis 2.7.1 unpacking the equipment inspect the equipment for any physical damage. If you are not sure about the function of a component, review the associated information within this manual. Contact your authorized nec sales representative if...

  • Page 111

    Univerge sv8100 issue 7.0 system hardware manual 3 - 41 2.7.3 installing the 19” controlling chassis 1. Ensure the chassis is powered down. 2. Align the cd-cp00 blade with the slot 1 guides of the controlling chassis. 3. Slide the cd-cp00 blade into the chassis until resistance (back plane) is felt....

  • Page 112

    Issue 7.0 univerge sv8100 3 - 42 installing the sv8100 chassis 4. Gently push until the blade seats. Tighten the two retaining screws on front of the blade. 2.7.4 installing expansion blades in the 19” chassis (optional) when adding additional chassis to the system to expand the capacity, a pz-bs10 ...

  • Page 113

    Univerge sv8100 issue 7.0 system hardware manual 3 - 43 2.7.4.1 connector pin-out on the pz-bs10/pz-bs11 2.7.4.2 install the pz-bs10 expansion base blade in the chs2u controlling chassis 1. Ensure the chassis is powered down. 2. Locate the door positioned on the left end (expansion bay) of the contr...

  • Page 114

    Issue 7.0 univerge sv8100 3 - 44 installing the sv8100 chassis 3. From the left side of the chassis, pull cover outward to expose the expansion bay. 4. Pull the cover toward you to remove. . Cover must be removed prior to installation of pz-bs10 blade. 5. Align the pz-bs10 blade with the guides loca...

  • Page 115

    Univerge sv8100 issue 7.0 system hardware manual 3 - 45 6. Slide the pz-bs10 blade into the chassis until resistance (back plane) is felt. 7. Gently push until the blade seats and install the supplied retaining screw. Figure 3-51 pz-bs10 components figure 3-52 installing pz-bs10 blade in expansion b...

  • Page 116

    Issue 7.0 univerge sv8100 3 - 46 installing the sv8100 chassis 8. Align the door tabs with hinges and reattach the cover. 9. Close the pz-bs10 cover. 2.7.4.3 install the pz-bs11 expansion blade in the chs2u expansion chassis . For the expansion chassis to function, the pz-bs10 blade must be installe...

  • Page 117

    Univerge sv8100 issue 7.0 system hardware manual 3 - 47 2. Locate the door positioned on the left end (expansion bay) of the expansion chassis. 3. From the left side of the chassis, pull cover outward to expose the expansion bay. Figure 3-55 pz-bs11 expansion bay in expansion chassis figure 3-56 ope...

  • Page 118

    Issue 7.0 univerge sv8100 3 - 48 installing the sv8100 chassis 4. Pull the cover toward you to remove. . Cover must be removed to install pz-bs11 blade. 5. Align the pz-bs11 blade with the guides located within the expansion bay. 6. Slide the pz-bs11 blade into the chassis until resistance (back pla...

  • Page 119

    Univerge sv8100 issue 7.0 system hardware manual 3 - 49 8. Align the door tabs with hinges and reattach the cover. 9. Close the pz-bs11 blade cover. Figure 3-59 pz-bs11 blade installed figure 3-60 pz-bs11 installed (cover closed).

  • Page 120

    Issue 7.0 univerge sv8100 3 - 50 installing the sv8100 chassis 2.7.4.4 connect the controlling and expansion chassis . Installment of the pz-bs10 blade and pz-bs11 blade(s) must be completed prior to installation of the provided (cat 5) expansion cabling. 1. Ensure controlling and expansion chassis ...

  • Page 121

    Univerge sv8100 issue 7.0 system hardware manual 3 - 51 3. Repeat for additional expansion chassis. Figure 3-62 system expansion cabling install in controlling chassis install in expansion chassis install in expansion chassis install in expansion chassis.

  • Page 122

    Issue 7.0 univerge sv8100 3 - 52 installing the sv8100 chassis 2.7.5 install 19” chassis grounding from the factory, the sg, eth and pbxg grounds are located inside the chassis and are connected to the fg ground (frame ground) on the back of the chassis. Each chassis (chs2u) in the system must be gr...

  • Page 123

    Univerge sv8100 issue 7.0 system hardware manual 3 - 53 2.7.7 install ac power cords 1. Locate the supplied ac power cord and attach to the ac inlet located on the back of the controlling chassis. Figure 3-64 19” chassis grounding lug (multiple-chassis) figure 3-65 install the ac power cord fg lugs ...

  • Page 124

    Issue 7.0 univerge sv8100 3 - 54 installing the sv8100 chassis 2.7.8 install ac power cords on multiple-chassis (optional) 1. Locate the supplied ac power cords and attach to the ac inlets located on the back of the controlling and expansion chassis. 2.7.9 install additional blades refer to chapter ...

  • Page 125

    Univerge sv8100 issue 7.0 system hardware manual 3 - 55 back side of the chassis to an electrical service ground (such as a cold water pipe). 2.8.1 install ac power cord 9.5” chassis locate the supplied ac power cord and attach to the ac inlet located on the back of the chassis [refer to figure 3-67...

  • Page 126

    Issue 7.0 univerge sv8100 3 - 56 installing the sv8100 chassis s ection 3 b attery c onnection there are two types of battery connection to provide battery life in the event of a power failure, the internal battery and an external battery with chs large batt box. 3.1 installing the internal batterie...

  • Page 127

    Univerge sv8100 issue 7.0 system hardware manual 3 - 57 4. Remove access panel containing the fan. Refer to figure 3-69 removing access panel and figure 3-70 access panel removed . Figure 3-69 removing access panel figure 3-70 access panel removed.

  • Page 128

    Issue 7.0 univerge sv8100 3 - 58 installing the sv8100 chassis 5. Using tie wraps, secure chs2u batt cable int in cable guide bracket (refer to figure 3-71 installing cable guide ). 6. With supplied screw, install cable guide in chassis (refer to figure 3-72 installing cable guide ). Figure 3-71 ins...

  • Page 129

    Univerge sv8100 issue 7.0 system hardware manual 3 - 59 7. Install two 2.3 ah-12v batteries (locally procured) into the chs2u batt mtg kit (refer to figure 3-73 installing two batteries ). . The first battery must be installed on the left side, then slid to the right due to an installation tab on th...

  • Page 130

    Issue 7.0 univerge sv8100 3 - 60 installing the sv8100 chassis 9. Connect the provided battery cables to the batteries (refer to figure 3-74 installing battery cable ). 10. Connect chs2u batt cable int to battery connector (refer to figure 3-75 connecting chs2u batt cable int ). Figure 3-74 installi...

  • Page 131

    Univerge sv8100 issue 7.0 system hardware manual 3 - 61 11. Install chs2u batt mtg kit into chs2u chassis and tighten the retaining screws (see figure 3-76 installing battery tray into chs2u chassis ). 12. Reinstall access panel containing the fan and secure with supplied screw (refer to figure 3-77...

  • Page 132

    Issue 7.0 univerge sv8100 3 - 62 installing the sv8100 chassis 3.2 installing the external batteries an optional (locally procured), external battery source can be used to provide power in the event of a power failure. Chs large batt box (backup time = three hours for 30 terminals) 3.2.1 floor mount...

  • Page 133

    Univerge sv8100 issue 7.0 system hardware manual 3 - 63 2. Mark and drill the four holes required for installing the chs base unit. 3. Align bolt holes in chs base unit (see figure 3-78 floor mount spacing guide on page 3-63 ) with holes drilled in floor and secure using four anchor bolts. 4. Align ...

  • Page 134

    Issue 7.0 univerge sv8100 3 - 64 installing the sv8100 chassis 5. Secure the chs large batt box to the chs base unit using the chs2u joint bracket kit. Refer to figure 3-79 installing the chs large batt box using the chs2u joint bracket kit on page 3-64 . 3.2.2 battery installation 1. Loosen screw o...

  • Page 135

    Univerge sv8100 issue 7.0 system hardware manual 3 - 65 3. Remove two screws from front of battery tray suppressor. Refer to figure 3-81 removing battery tray suppressor . 4. Slide battery tray suppressor outward to remove. 5. Slide battery tray(s) out of chs large batt box. 6. Loosen two screws and...

  • Page 136

    Issue 7.0 univerge sv8100 3 - 66 installing the sv8100 chassis 7. Remove two screws and remove the battery tray bracket. Refer to figure 3-83 removing battery tray bracket . 8. Refer to figure 3-84 connecting battery cables for connection of battery cable to battery terminals. Repeat for additional ...

  • Page 137

    Univerge sv8100 issue 7.0 system hardware manual 3 - 67 9. Install batteries into battery tray. Refer to figure 3-85 connecting battery cables . 10. Using two screws, install the battery tray bracket. Refer to figure 3-83 removing battery tray bracket on page 3-66 . 11. Insert battery connection cab...

  • Page 138

    Issue 7.0 univerge sv8100 3 - 68 installing the sv8100 chassis 16. Insert tabs on cover into holes on chs large batt box. Slide the cover left until seated and tighten the screw. Refer to figure 3-87 installing cover battery . 3.2.3 chs large batt box to chs2u connection 1. Power down the chs2u chas...

  • Page 139

    Univerge sv8100 issue 7.0 system hardware manual 3 - 69 3. Remove fan access panel from rear of chs2u chassis. Refer to figure 3-88 removing fan access panel . 4. Connect one end of battery connection cable to battery connector on rear of basic and expansion chassis. 5. Connect other end of cable to...

  • Page 140

    Issue 7.0 univerge sv8100 3 - 70 installing the sv8100 chassis figure 3-90 single chs large batt box connection figure 3-91 dual chs large batt box connection expansion basic basic expansion.

  • Page 141

    Univerge sv8100 issue 7.0 system hardware manual 3 - 71 6. Insert the access panel tab into the rear of the chs1u-us chassis running the battery connection cable through the cutout. Secure panel with the retaining screw. Refer to figure 3-92 install the fan access panel . 7. Connect grounding and ac...

  • Page 142

    Issue 7.0 univerge sv8100 3 - 72 installing the sv8100 chassis 3.3 installing the external batteries 9.5” chassis an optional, chsgw small batt box can be installed to provide external battery power to the chs2u gw chassis during a power failure. The short- term battery box will power the system for...

  • Page 143

    Univerge sv8100 issue 7.0 system hardware manual 3 - 73 5. The metal bracket is placed on top of the batteries and able to hold them in place. Insert the metal tabs of the bracket into the slots on the side of the battery compartment and lower into place. Using the two screws provided, attach the br...

  • Page 144

    Issue 7.0 univerge sv8100 3 - 74 installing the sv8100 chassis 7. Reattach the cover with the two screws previously removed. 3.3.2 chsgw small batt box to chs2u gw connection 1. Power down the chs2u gw chassis. 2. Disconnect ac power cable from rear of chassis. 3. From the back of the 9.5” chassis, ...

  • Page 145

    Univerge sv8100 issue 7.0 system hardware manual 3 - 75 4. Secure the battery compartment to the chassis using the two screws provided and attach the battery cable to the 9.5” chassis. 5. Reconnect ac power cable to rear of chassis. 6. To power on the 9.5” chassis, refer to chapter 4 , 2.6 powering ...

  • Page 146

    Issue 7.0 univerge sv8100 3 - 76 installing the sv8100 chassis 3. Unplug all the cable connectors from the battery box. 4. Loosen the two thumb screws on the battery box and remove the box by pulling on the two thumb screws. 5. Replace the fuse(s) as needed. 6. Replace the battery box and tighten th...

  • Page 147

    Univerge sv8100 issue 7.0 system hardware manual 3 - 77 s ection 4 r emove and i nstall c ooling f an if required, the cooling fan installed in the chs2u chassis can be removed and replaced. The following provides the procedure for the chs2u chassis. 4.1 chs2u chassis 4.1.1 remove cooling fan 1. Ens...

  • Page 148

    Issue 7.0 univerge sv8100 3 - 78 installing the sv8100 chassis 3. Swing access panel outward and unplug fan power cable. See figure 3-102 opening chassis access panel (19” chassis) . 4. Remove chassis access panel from rear of chassis. 5. Remove cabling from retention clips. See figure 3-103 chassis...

  • Page 149

    Univerge sv8100 issue 7.0 system hardware manual 3 - 79 4.1.2 install cooling fan 1. Align replacement fan with holes and secure with two screws (refer to figure 3-103 chassis access panel removed on page 3-78 . 2. Install cabling into retention clips (refer to figure 3-103 chassis access panel remo...

  • Page 150

    Issue 7.0 univerge sv8100 3 - 80 installing the sv8100 chassis.

  • Page 151: Installing The Sv8100 Blades

    System hardware manual 4 - 1 chapter 4 installing the sv8100 blades s ection 1 g eneral i nformation this chapter contains information to help the technician install the blades for the univerge sv8100 system. The technician should be familiar with this section before installing any equipment. 1.1 sl...

  • Page 152

    Issue 7.0 univerge sv8100 4 - 2 installing the sv8100 blades figure 4-1 chassis cpu and expansion slot locations 19” controlling chassis cpu slot 19 “expansion chassis pz-bs11 slot 9.5 “ chassis.

  • Page 153

    Univerge sv8100 issue 7.0 system hardware manual 4 - 3 s ection 2 i nstallation pre-installation planning is essential. Advanced planning minimizes installation time, cost, and disruption of the customer business activities. 2.1 installation and safety precautions never install telephone wiring duri...

  • Page 154

    Issue 7.0 univerge sv8100 4 - 4 installing the sv8100 blades 2.2 installing an extension or trunk blade 2.2.1 installing the blades to install an extension/trunk blade with the system running: 1. Insert the blade within the guide rail and push the blade securely into position. Tighten the thumb scre...

  • Page 155

    Univerge sv8100 issue 7.0 system hardware manual 4 - 5 2.2.2 order of installing extension blades the order in which the station blades (cd-8dlca, cd-16dlca, pz-8dlcb and cd-4lca, cd-8lca, pz-8lce) are physically inserted determines the numbering plan. For example, when a digital station blade (cd-1...

  • Page 156

    Issue 7.0 univerge sv8100 4 - 6 installing the sv8100 blades the system automatically recognizes each blade installed in the system. If a blade has previously been installed in a slot and another type of blade is to be installed in that same slot, the blade must first be removed from the chassis and...

  • Page 157

    Univerge sv8100 issue 7.0 system hardware manual 4 - 7 for example, if four blades are installed in the following order, the numbering plan below applies. Table 4-3 trunk blade installation order example order of installation blade slot number blade line circuits 1 4 cd-4cota with pz-4cote 1~8 2 5 c...

  • Page 158

    Issue 7.0 univerge sv8100 4 - 8 installing the sv8100 blades 2.2.3.2 installing cd-prta (t1/pri) blades the cd-prta (t1/pri) interface blade uses the first block of 24 consecutive trunks. For example, if an cd-4cota and pz-4cote blade is installed for trunks 1~8, the cd-prta (t1/pri) blade automatic...

  • Page 159

    Univerge sv8100 issue 7.0 system hardware manual 4 - 9 2.5 blade capacities the universal architecture of the univerge sv8100 provides flexibility when installing blades. With the exception of the cd-cp00 and cc-cp00 blades, any blade can be installed in any slot. Table 2-4 maximum system capacities...

  • Page 160

    Issue 7.0 univerge sv8100 4 - 10 installing the sv8100 blades 2.6.2 performing a hot start the section describes how to load system software from flash memory and customer data from ram memory. 1. Turn the system power off. 2. After it has powered down, press the button again to power the system bac...

  • Page 161

    Univerge sv8100 issue 7.0 system hardware manual 4 - 11 2.6.3.2 port defaults with the default settings, the ports are assigned as follows: in the initial configuration: all programmable function keys are line keys (e.G., key 1 is line 1). All trunks are loop start dtmf. 2.6.3.3 setting up extension...

  • Page 162

    Issue 7.0 univerge sv8100 4 - 12 installing the sv8100 blades 2.6.3.4 saving your configuration when programming is completed, to exit out of the program option and save changes to the cd-cp00: 1. Press exit to exit the program options, if needed. 2. Press speaker. Saving system data is displayed if...

  • Page 163

    Univerge sv8100 issue 7.0 system hardware manual 4 - 13 after reloading the customer data to the system, exit programming mode (this could take a minute or more to save the database), then reset the system by powering down and back up. If the system is not reset, not all the uploaded programming cha...

  • Page 164

    Issue 7.0 univerge sv8100 4 - 14 installing the sv8100 blades to save customer data prior to updating, a blank usb memory is required. Insert the usb memory into the usb port on the cd-cp00 blade. Use program 90-03 to save the software to the usb memory. Note that a usb memory can only hold one cust...

  • Page 165

    Univerge sv8100 issue 7.0 system hardware manual 4 - 15 to perform a system software and firmware upgrade: 1. Turn the system power off. 2. Once the system has powered down, insert the usb memory containing the software upgrade into the usb port on the cd-cp00. 3. Push in and hold the load button. 4...

  • Page 166

    Issue 7.0 univerge sv8100 4 - 16 installing the sv8100 blades s ection 3 c ommon c ontrol b lades the blades described in this section control the common functions of the chassis. 3.1 cd-cp00 (sv8100 central processing unit) figure 4-3 cd-cp00 blade layout fast ethernet cn7 cn6 bgm/exsp control cn 1...

  • Page 167

    Univerge sv8100 issue 7.0 system hardware manual 4 - 17 3.1.1 description the cd-cp00 controls all the functions and operations of the sv8100 system using the system software loaded into the cd-cp00 memory. The system software can be upgraded as new software becomes available. One cd-cp00 blade must...

  • Page 168

    Issue 7.0 univerge sv8100 4 - 18 installing the sv8100 blades pz-bs10/pz-bs11 interface circuit main processing 32-bit cpu circuit (mpc8248 @ 2 66 mhz) time switch, optional blade control circuit backboard interface circuit the cd-cp00 provides: 200 trunk ports maximum 512 extension ports maximum – ...

  • Page 169

    Univerge sv8100 issue 7.0 system hardware manual 4 - 19 mf signal sender (sends caller information to co for e911) call progress tone detection c-channel control conference: 64 channels caller id receiver; 32 channels caller id generator; 4 or 10 channels for analog stations this can be expanded up ...

  • Page 170

    Issue 7.0 univerge sv8100 4 - 20 installing the sv8100 blades rtp forwarding vocoder conversion 3.1.2 installation each sv8100 system must have the cd-cp00 installed in slot 1 of the controlling chassis. 1. Install the battery on the cd-cp00. The polarity “+” symbol must be on top as illustrated in ...

  • Page 171

    Univerge sv8100 issue 7.0 system hardware manual 4 - 21 2. Refer to figure 4-4 cd-cp00 blade with daughter boards installed on page 4-17 to install the pz-vm21, pz-me50 and/or pz-32ipla/pz-64ipla/pz-128ipla daughter board, if required. 3. Ensure the power supply is off, then slide the cpu into the c...

  • Page 172

    Issue 7.0 univerge sv8100 4 - 22 installing the sv8100 blades customer information is stored in the ram memory and, in case of a power failure, will be restored. The lithium battery in the system saves the ram memory when power is lost. 3.1.3 switch settings refer to table 4-5 cd-cp00 switch setting...

  • Page 173

    Univerge sv8100 issue 7.0 system hardware manual 4 - 23 run (led 1) = the cpu is operating (green) led 2, and 3 = alarms (red) led 4 = flash access indication (red) led 5 = the usb memory connection status (red) (led off when no usb memory installed) refer to program 90-10: system alarm setup for de...

  • Page 174

    Issue 7.0 univerge sv8100 4 - 24 installing the sv8100 blades 3.1.5 connectors table 4-8 cd-cp00 connections describes each connector on the cd-cp00 , table 4-9 cd-lta rj45 cable connector pin-outs describes the pin-outs for connectors on the ccpu-a. Refer to figure 4-3 cd-cp00 blade layout on page ...

  • Page 175

    Univerge sv8100 issue 7.0 system hardware manual 4 - 25 table 4-9 cd-lta rj45 cable connector pin-outs usb cable connector – cn5 (type a, female) (usb 1.1/2.0 standard) pin no. Signal 1 vcc 2 -d 3 +d 4 gnd ethernet cable connector – cn7 (rj-45) (10base-t/100base-tx port) pin no. Connection 1 tx+ 2 t...

  • Page 176

    Issue 7.0 univerge sv8100 4 - 26 installing the sv8100 blades pin no. Connection 1 nc 2 nc 3 excnt2 4 excnt1 5 excnt1 6 excnt2 7 nc 8 nc table 4-9 cd-lta rj45 cable connector pin-outs (continued) 1 8.

  • Page 177

    Univerge sv8100 issue 7.0 system hardware manual 4 - 27 3.2 pz-me50 (memory expansion daughter board) 3.2.1 description the memory expansion daughter board (pz-me50) provides additional memory for the system for use with license control, expanded system networking, inmail e-mail notification, and so...

  • Page 178

    Issue 7.0 univerge sv8100 4 - 28 installing the sv8100 blades table 4-11 pz-me50 capacities provides the memory capacities for the pz-me50 blades. Table 4-12 pz-me50 capacities provides the maximum capacities for the pz-me50 blade. 3.2.2 installation to install a pz-me50 on the cd-cp00: table 4-11 p...

  • Page 179

    Univerge sv8100 issue 7.0 system hardware manual 4 - 29 for installation on the cd-cp00 blade refer to figure 4-4 cd-cp00 blade with daughter boards installed on page 4-17 . . This daughter board does not have any switches which need to be set and does not require any hardware setting. Each node in ...

  • Page 180

    Issue 7.0 univerge sv8100 4 - 30 installing the sv8100 blades 3.3 pz-vm21 (voice mail daughter board inc. V34 modem) 3.3.1 description the sv8100 voice mail is a fully integrated, “in-skin” voice mail with automated attendant. In addition to the voice mail function, the daughter board provides voice...

  • Page 181

    Univerge sv8100 issue 7.0 system hardware manual 4 - 31 3.3.2 installation to install a pz-vm21 on the cd-cp00: 1. Included with the pz-vm21 are four plastic spacers. Install the plastic spacers onto the pz-vm21. Make sure to attach the spacers so that they extend out on the side of the daughter boa...

  • Page 182

    Issue 7.0 univerge sv8100 4 - 32 installing the sv8100 blades one pz-vm21 daughter board providing inmail can be installed per system. Refer to the univerge univerge sv8100 system inmail system guide for complete set-up information. Figure 4-8 installing the pz-vm21.

  • Page 183

    Univerge sv8100 issue 7.0 system hardware manual 4 - 33 3.3.3 switch settings this daughter board does not have any switch that needs to be set and does not require any hardware setting. 3.3.4 remote pc programming access the vm21 card provides a v34 modem for pc programming connection. The modem is...

  • Page 184

    Issue 7.0 univerge sv8100 4 - 34 installing the sv8100 blades boards) figure 4-9 pz-32ipla voipdb-32 daughter board figure 4-10 pz-64ipla voipdb-64 blade.

  • Page 185

    Univerge sv8100 issue 7.0 system hardware manual 4 - 35 3.4.1 description the pz-32ipla/pz-64ipla/pz-128ipla daughter boards are used for converting the rtp (real time transfer protocol) packets via the ip network and pcm highway. The daughter board is installed on the cd-cp00. The ip telephones are...

  • Page 186

    Issue 7.0 univerge sv8100 4 - 36 installing the sv8100 blades table 4-14 ipla daughter board maximum upgrade capacities provides the maximum capacities for the voipdb blades when they are upgraded. When installing a ipla daughter board, the system allocates the maximum number of trunk ports for the ...

  • Page 187

    Univerge sv8100 issue 7.0 system hardware manual 4 - 37 3.4.4 led indications led indications for the pz-32ipla, pz-64ipla and pz-128ipla daughter boards are indicated in table 4-17 iplb daughter board led indications . Each led is listed with its associated function and led and operational status. ...

  • Page 188

    Issue 7.0 univerge sv8100 4 - 38 installing the sv8100 blades 3.4.5 connectors figure 4-14 voip connections shows a typical connection layout. Figure 4-15 connecting a ipla daughter board to a network/pc illustrates how to connect a voip daughter board to a network or pc. Figure 4-12 voip connection...

  • Page 189

    Univerge sv8100 issue 7.0 system hardware manual 4 - 39 3.5 pz-32iplb/pz-64iplb/pz-128iplb (voice over ip daughter boards) 3.5.1 description the current pz-32/64/128 ipla daughter board requires a maximum of eight dsp ip addresses. The new pz-32/64/128 iplb requires only one dsp ip address for all t...

  • Page 190

    Issue 7.0 univerge sv8100 4 - 40 installing the sv8100 blades 3.5.2 installation to install a pz-32iplb/pz-64iplb/pz-128iplb on the cd-cp00 : 1. With the system power off, remove the cd-cp00. 2. Install the ipla daughter board onto the cd-cp00 blade. 3. Insert the cd-cp00 into slot 1 in the controll...

  • Page 191

    Univerge sv8100 issue 7.0 system hardware manual 4 - 41 the following table shows the led indication when transmitting or receiving data on cn1. Table 4-18 voipdb led cn1 transmit/receive data indications led link up auto negotiation mode force mode 1000 m bps 100mbps 10mbps 1000 m bps 100mbps 10mbp...

  • Page 192

    Issue 7.0 univerge sv8100 4 - 42 installing the sv8100 blades 3.5.5 connectors figure 4-14 voip connections shows a typical connection layout. Figure 4-15 connecting a ipla daughter board to a network/pc illustrates how to connect a voip daughter board to a network or pc. Figure 4-14 voip connection...

  • Page 193

    Univerge sv8100 issue 7.0 system hardware manual 4 - 43 figure 4-15 connecting a ipla daughter board to a network/pc.

  • Page 194

    Issue 7.0 univerge sv8100 4 - 44 installing the sv8100 blades s ection 4 s tation b lades 4.1 cd-8dlca/cd-16dlca (digital station interface) figure 4-16 cd-8dlca blade.

  • Page 195

    Univerge sv8100 issue 7.0 system hardware manual 4 - 45 4.1.1 description these blades provide: 8 (cd-8dlca) or 16 (cd-16dlca) digital extension circuits (used for digital telephones, dss consoles, slt(1)-u( ) adp, pgd(2)-u10 adp adapters) these ports provide -48v feeding. Two blade status leds – on...

  • Page 196

    Issue 7.0 univerge sv8100 4 - 46 installing the sv8100 blades table 4-19 cd-8dlca/cd-16dlca maximum upgrade capacities provides the maximum capacities for the esiu blades when they are upgraded. 4.1.2 installation the cd-8dlca/cd-16dlca blades can be installed in any universal slot in the system and...

  • Page 197

    Univerge sv8100 issue 7.0 system hardware manual 4 - 47 4.1.4 connectors the cnx01 connectors provide connection to four digital station ports. With the cd-16dlca blade, the cn101, cn201, cn301, and cn401 connectors are available. With the cd-8dlca blade the cn301 and cn401connectors are removed fro...

  • Page 198

    Issue 7.0 univerge sv8100 4 - 48 installing the sv8100 blades table 4-21 cd-8dlca/cd-16dlca/ rj-61 cable connector pin-outs rj-61 cable connector cd-8dlca – cn101 (ports 1~4), cn201 (ports 5~8) cd-16dlca – cn101 (ports 1~4), cn201 (ports 5~8), cn301 (ports 9~12), cn401 (ports 13~16) pin no. Connecti...

  • Page 199

    Univerge sv8100 issue 7.0 system hardware manual 4 - 49 4.2 pz-8dlcb (digital station daughter board) 4.2.1 description the pz-8dlcb daughter board provides eight digital extensions. This daughter board is installed on the cd-8dlca and expands the port capacity for the combined blades to 16. Table 4...

  • Page 200

    Issue 7.0 univerge sv8100 4 - 50 installing the sv8100 blades 4.2.2 installation the pz-8dlcb is installed on the cd-8dlca. To install: 1. Connect the pz-8dlcb to the cn2 connector on the cd-8dlca blade. Refer to figure 4-16 cd-8dlca blade on page 4-44 for the location of the connectors on the blade...

  • Page 201

    Univerge sv8100 issue 7.0 system hardware manual 4 - 51 table 4-24 pz-8dlcb cn401 connection rj-61 cable connector cn401 (ports 13~16) pin no. Connection 1 (t4) tip for port 16 2 (t3) tip for port 15 3 (t2) tip for port 14 4 (r1) ring for port 13 5 (t1) tip for port 13 6 (r2) ring for port 14 7 (r3)...

  • Page 202

    Issue 7.0 univerge sv8100 4 - 52 installing the sv8100 blades 4.3 cd-4lca/ cd-8lca (4-port/8-port single line interface) figure 4-19 cd-4lca blade.

  • Page 203

    Univerge sv8100 issue 7.0 system hardware manual 4 - 53 4.3.1 description the 4/8sliu blade provides four (4sliu) analog extension ports or eight (8sliu) analog extension ports (used for on-premise analog telephones, fax machines, and analog modems). Figure 4-20 cd-8lca blade.

  • Page 204

    Issue 7.0 univerge sv8100 4 - 54 installing the sv8100 blades the 4sliu and 8sliu are not rated for opx use. A 4diopu blade should be used instead (it supports the analog did and single line telephone interface functions, such as off-premise extensions). One extension status led two blade status led...

  • Page 205

    Univerge sv8100 issue 7.0 system hardware manual 4 - 55 4.3.2 installation install the cd-4lca / cd-8lca blade into any available universal slot. . If the pz-4lca/pz-8lce is used, install this prior to inserting the cd-8lca into the chassis 4.3.3 led indications led indications for the cd-4lca / cd-...

  • Page 206

    Issue 7.0 univerge sv8100 4 - 56 installing the sv8100 blades off on unit busy a channel is busy (use another from ch1 ~ chx). – off all channels are idle. – flash (100ms on/off) downloading firmware. – table 4-26 cd-4lca/cd-8lca led indications (continued) led indication operation status remarks li...

  • Page 207

    Univerge sv8100 issue 7.0 system hardware manual 4 - 57 4.3.4 connectors table 4-27 cd-4lca/cd-8lca rj-61 cable connector pin-outs show the pin-outs for the rj-61 connector. Refer to figure 4-19 cd-4lca blade on page 4-52 and figure 4-20 cd-8lca blade on page 4-53 for illustrations showing the locat...

  • Page 208

    Issue 7.0 univerge sv8100 4 - 58 installing the sv8100 blades 4.4 pz-4lca/pz-8lce (4-port/8-port sli daughter boards) figure 4-21 installing the pz-4lca daughter board.

  • Page 209

    Univerge sv8100 issue 7.0 system hardware manual 4 - 59 figure 4-22 installing the pz-8lce daughter board.

  • Page 210

    Issue 7.0 univerge sv8100 4 - 60 installing the sv8100 blades 4.4.1 description the pz-4lca and pz-8lce daughter boards are mounted on the cd-4lca/cd-8lca. These boards provide: 4-port single line and 8-port single line analog extension ports (used for on-premise analog telephones, fax machines, and...

  • Page 211

    Univerge sv8100 issue 7.0 system hardware manual 4 - 61 4.4.2 installation these daughter boards can be installed on the cd-4lca or cd-8lca blades. To install the pz-4lca / pz-8lce : 1. Included with the slidb are four plastic spacers. Install the plastic spacers onto either the cd-4lca or cd-8lca. ...

  • Page 212

    Issue 7.0 univerge sv8100 4 - 62 installing the sv8100 blades 4.4.3 connectors table 4-29 pz-4lca/pz-8lce/ rj-61 cable connector pin-outs show the pin-outs for the rj-61 connector. Refer to figure 4-21 installing the pz-4lca daughter board on page 4-58 and figure 4-22 installing the pz-8lce daughter...

  • Page 213

    Univerge sv8100 issue 7.0 system hardware manual 4 - 63 dc voltage (on hook) (-28vdc) feeding polarity reverse ability ring generator (75vrms, 16hz/20hz/25hz selectable by cm82-04-02) caller id sending ability message wait lamping ability (110v dc) cable length = 600ohms (including the slt). Approxi...

  • Page 214

    Issue 7.0 univerge sv8100 4 - 64 installing the sv8100 blades table 4-31 cd-16lcah led indications led indication operation status remarks live led (green) busy led (red) on on system initializing – flash (1s) on the assignment of the unit is refused. When you exceed the system capacity. When the ma...

  • Page 215

    Univerge sv8100 issue 7.0 system hardware manual 4 - 65 4.5.4 connectors table 4-32 cd-16lcah rj-61 cable connector pin-outs show the pin-outs for the rj-61 connector. Table 4-32 cd-16lcah rj-61 cable connector pin-outs rj-61 cable connector 8sliu – cn2 (ports 1~4) 8sliu – cn2 (ports 1~4), cn3 (port...

  • Page 216

    Issue 7.0 univerge sv8100 4 - 66 installing the sv8100 blades 4.6 cd-lta (d term /slt combination) 4.6.1 description the digital station/slt combination blade provides eight digital station ports and two analog ports. This blade allows for either a pz-4cote analog trunk daughter board or pz-2bria da...

  • Page 217

    Univerge sv8100 issue 7.0 system hardware manual 4 - 67 eight digital station ports two analog extension ports two status leds table 4-33 cd-lta maximum upgrade capacities provides the maximum capacities for the cd-lta blades when they are upgraded. 4.6.2 installation install the cd-lta blade into a...

  • Page 218

    Issue 7.0 univerge sv8100 4 - 68 installing the sv8100 blades 4.6.3 led indications led indications for the cd-lta are indicated in table 4-34 cd-lta led indications . Each led is listed with its associated function and led and operational status. Refer to figure 4-23 cd-lta blade on page 4-66 for t...

  • Page 219

    Univerge sv8100 issue 7.0 system hardware manual 4 - 69 4.6.4 connectors table 4-35 cd-lta rj61 cable connector pin-outs on page 4-69 shows the pin-outs for the rj-61 connector. Refer to figure 4-23 cd-lta blade on page 4-66 for an illustration showing the location of the connectors on the cd-lta bl...

  • Page 220

    Issue 7.0 univerge sv8100 4 - 70 installing the sv8100 blades 4.7 cd-8ltch (d term /slt/loop start analogue trunk combination) 4.7.1 description the digital station/slt/loop start analogue trunk combination blade provides eight digital station ports, two analog ports and four loop start analogue tru...

  • Page 221

    Univerge sv8100 issue 7.0 system hardware manual 4 - 71 4.7.3 led indications led indications for the cd-8ltch are indicated in table 4-37 cd- 8ltch led indications . Each led is listed with its associated function and led and operational status. Table 4-37 cd-8ltch led indications led indication op...

  • Page 222

    Issue 7.0 univerge sv8100 4 - 72 installing the sv8100 blades 4.7.4 connectors table 4-38 cd-8ltch rj61 cable connector pin-outs on page 4-72 shows the pin-outs for the rj-61 connector. Table 4-38 cd-8ltch rj61 cable connector pin-outs rj61 cable connector digital: cn1 (ports 1~4) digital: cn2 (port...

  • Page 223

    Univerge sv8100 issue 7.0 system hardware manual 4 - 73 pin no. Connection 1 circuit 4 – tip 2 circuit 3 – tip 3 circuit 2 – tip 4 circuit 1 – ring 5 circuit 1 – tip 6 circuit 2 – ring 7 circuit 3 – ring 8 circuit 4 – ring table 4-38 cd-8ltch rj61 cable connector pin-outs (continued).

  • Page 224

    Issue 7.0 univerge sv8100 4 - 74 installing the sv8100 blades s ection 5 t runk b lades 5.1 cd-4cota (4 loop start interface) 5.1.1 description the coiu blade provides: cd-4cota: four analog loop start trunk circuits one trunk status led figure 4-24 cd-4cota blade.

  • Page 225

    Univerge sv8100 issue 7.0 system hardware manual 4 - 75 one blade status led four caller id circuits two power failure transfer circuits connection for coidb daughter board the 4coiu blade consumes four trunk ports ranging between ports 001~200. The cn2 connector provides connection to four analog t...

  • Page 226

    Issue 7.0 univerge sv8100 4 - 76 installing the sv8100 blades 5.1.2 installation install the coiu blade into an available slot in the chassis. (refer to figure 4-24 cd-4cota blade on page 4-74 for a layout of the blade.) . If the pz-4cote is to be used, install this prior to inserting the cd-4cota b...

  • Page 227

    Univerge sv8100 issue 7.0 system hardware manual 4 - 77 5.1.4 connectors table 4-41 cd-4cota rj-61 cable connector pin-outs on page 4-77 shows the pin-outs for the rj-61 connector. Refer to figure 4-24 cd-4cota blade on page 4-74 for an illustration showing the location of the connectors on the 4coi...

  • Page 228

    Issue 7.0 univerge sv8100 4 - 78 installing the sv8100 blades 5.2 pz-4cote (4 loop start interface daughter board) 5.2.1 description the pz-4coteblade provides: pz-4cote: four analog loop start trunk circuits four caller id circuits connector for coiu blade connector for cd-lta figure 4-25 installin...

  • Page 229

    Univerge sv8100 issue 7.0 system hardware manual 4 - 79 the pz-4cote consumes four trunk ports ranging between ports 001~200. The cn2 connector provides connection to four analog trunk ports, which are polarity sensitive (tip-to-tip, ring-to-ring). The power failure circuits (cn3), however, are not ...

  • Page 230

    Issue 7.0 univerge sv8100 4 - 80 installing the sv8100 blades 5.2.2 installation to install the pz-4cote : 1. Four plastic spacers are included with the coidb. Install the plastic spacers on the cd-4cota or cd-lta blade. Make sure to attach the spacers so that they extend out on the side of the daug...

  • Page 231

    Univerge sv8100 issue 7.0 system hardware manual 4 - 81 5.3 cd-8cotah (8 port analogue trunk card) 5.3.1 description the cd-8cotah blade provides: eight analogue loop start trunk circuits one trunk status led one blade status led eight caller id circuits two power failure transfer circuits the 4coiu...

  • Page 232

    Issue 7.0 univerge sv8100 4 - 82 installing the sv8100 blades the connectors provides connection to four analog trunk ports, which are polarity sensitive (tip-to-tip, ring-to-ring). The power failure circuits (cn3), however, are not polarity sensitive. Table 4-44 cd-8cotah maximum upgrade capacities...

  • Page 233

    Univerge sv8100 issue 7.0 system hardware manual 4 - 83 5.3.2 installation install the cd-8cotah blade into an available slot in the chassis. 5.3.3 led indications led indications for the cd-4cota are listed in table 4-45 cd- 8cotah led indications . Each led is listed with its associated function a...

  • Page 234

    Issue 7.0 univerge sv8100 4 - 84 installing the sv8100 blades 4-84 shows the pin-outs for the rj-61 connector. Table 4-46 cd-8cotah rj-61 cable connector pin-outs rj-61 cable connector – cn2, trunks the cn2 connector is polarity sensitive (tip-to-tip, ring-to-ring). Pin no. Connection 1 circuit 4 – ...

  • Page 235

    Univerge sv8100 issue 7.0 system hardware manual 4 - 85 rj-61 cable connector cn2, trunks the cn2 connector is polarity sensitive (tip-to-tip, ring-to-ring). Pin no. Connection 1 circuit 8 – tip 2 circuit 7 – tip 3 circuit 6 – tip 4 circuit 5 – ring 5 circuit 5 – tip 6 circuit 6 – ring 7 circuit 7 –...

  • Page 236

    Issue 7.0 univerge sv8100 4 - 86 installing the sv8100 blades 5.4 cd-2bria (2 basic rate interface) 5.4.1 description this unit is an interface unit that accommodates an isdn (basic rate) circuit. The bri blade provides: two (cd-2bria) 2-channel circuits (2b + d) configured as t-bus figure 4-26 cd-2...

  • Page 237

    Univerge sv8100 issue 7.0 system hardware manual 4 - 87 64 kb/s clear b-channel and 16 kb/s d-channel two status leds connector for pz-2bria these trunk circuits can be connected to either isdn trunks or isdn telephones, depending on the switch setting within system programming. All isdn telephone c...

  • Page 238

    Issue 7.0 univerge sv8100 4 - 88 installing the sv8100 blades 3. Connect the cable from the nt1 network termination cable to the cn7 or cn8 connector on the cd-2bria blade and/or pz-2bria daughter board. (refer to figure 4-26 cd-2bria blade on page 4-86 for the location of the connectors on the blad...

  • Page 239

    Univerge sv8100 issue 7.0 system hardware manual 4 - 89 5.4.4 connectors table 4-49 cd-2bria rj-45 t-bus cable connector pin-outs show the pin-outs for the rj-45 cable connector for s-bus and t-bus connections. Refer to figure 4-26 cd-2bria blade on page 4-86 for an illustration showing the location...

  • Page 240

    Issue 7.0 univerge sv8100 4 - 90 installing the sv8100 blades the switches 6 and 7 define if the terminators are active. These should be set to on, if the bus has no termination. If the bus is already terminated they may be set to off. Every isdn-bus must be terminated with a set of 100ohm resistors...

  • Page 241

    Univerge sv8100 issue 7.0 system hardware manual 4 - 91 5.5 pz-2bria (2 basic rate interface daughter board) figure 4-27 installing the pz-2bria daughter board.

  • Page 242

    Issue 7.0 univerge sv8100 4 - 92 installing the sv8100 blades 5.5.1 description this daughter board provides two bri circuits and is installed on the cd-2bria blade. This board provides: two (cd-2bria) 2-channel circuits (2b + d) configured as t-bus or s-bus 64 kb/s clear b-channel and 16 kb/s d-cha...

  • Page 243

    Univerge sv8100 issue 7.0 system hardware manual 4 - 93 2. Before proceeding to step 3, wait to verify that the status led starts to flash. 3. Connect the cable from the nt1 network termination cable to the cn7 or cn8 connector on the cd-2bria and/or pz-2bria daughter board. 5.5.3 connectors table 4...

  • Page 244

    Issue 7.0 univerge sv8100 4 - 94 installing the sv8100 blades 5.5.4 termination switch settings when the card is installed it may be necessary to change the termination switch settings. These are found on the rear of the card, each circuit has one 8-position dip switch. The switches 6 and 7 define i...

  • Page 245

    Univerge sv8100 issue 7.0 system hardware manual 4 - 95 5.6 cd-4diopb (did/opx interface) 5.6.1 description the cd-4diopb supports the analog did and single line telephone interface functions (such as off-premise extension). The function type is assigned in programming for each port. The circuit typ...

  • Page 246

    Issue 7.0 univerge sv8100 4 - 96 installing the sv8100 blades four (4diopu) did trunk circuits or four opx circuits two blade status leds table 4-52 cd-4diopb maximum upgrade capacities provides the maximum capacities for the cd-4diopb blades when they are upgraded. 5.6.2 installation the cd-4diopb ...

  • Page 247

    Univerge sv8100 issue 7.0 system hardware manual 4 - 97 5.6.4 connectors the cn2 connector provides connection to four analog did trunk ports, which are polarity sensitive (tip-to-tip, ring-to-ring). The opx circuits, however, are not polarity sensitive. The diopu requires one universal slot. (refer...

  • Page 248

    Issue 7.0 univerge sv8100 4 - 98 installing the sv8100 blades 5.7 cd-prta (pri interface) 5.7.1 description the cd-prta pri blade provides an interface for isdn primary rate interface (pri) applications. This blade has a single 30-channel 64kb per second digital signal circuit configured for pri. Ea...

  • Page 249

    Univerge sv8100 issue 7.0 system hardware manual 4 - 99 basic pri call control (bcc) display of incoming caller’s name and number (when allowed by the telco) speech and 3.1 khz audio when installed, cd-prta uses the first block of 32 consecutive trunk ports. For example, if a coiu blade is installed...

  • Page 250

    Issue 7.0 univerge sv8100 4 - 100 installing the sv8100 blades layout for nt-1 network on page 4-100 for a cabling diagram.) the csu connects to the network through an 8-pin rj-45/rj48c connector. Use either the rj48c plug-to-rj48c plug, which ships with the csu or an rj-45/ 48c plug-to rj-45/48c pl...

  • Page 251

    Univerge sv8100 issue 7.0 system hardware manual 4 - 101 5.7.3 led indications led indications for the cd-prta are listed in table 4-56 cd-prta led indications . Each led is listed with its associated function and led and operational status. Refer to figure 4-31 cd-prta led indication pattern of lay...

  • Page 252

    Issue 7.0 univerge sv8100 4 - 102 installing the sv8100 blades figure 4-31 cd-prta led indication pattern of layer 1 on t1 unit table 4-57 isdn led indications alarm details of the alarm led indication pattern los loss of signal (red alarm) no signam (analogue interface) following an alarm blink (re...

  • Page 253

    Univerge sv8100 issue 7.0 system hardware manual 4 - 103 5.7.4 connectors table 4-58 cd-prta rj-45 cable connector pin-outs shows the pin-outs for the rj-45 connector. Refer to figure 4-29 cd-prta blade (front and side view) on page 4-98 for an illustration showing the location of the connectors on ...

  • Page 254

    Issue 7.0 univerge sv8100 4 - 104 installing the sv8100 blades table 4-59 cd-prta rj48c connector pin-outs shows the pin-outs for the 8-pin rj48c connector for the network and terminal interfaces. Table 4-59 cd-prta rj48c connector pin-outs network interface pinout for the 8-pin rj48c connector term...

  • Page 255

    Univerge sv8100 issue 7.0 system hardware manual 4 - 105 5.8 cd-4odtb (4-port tie line interface blade) 5.8.1 description the cd-4odtb tie line blade is an out band dial type analog tie line interface blade. This blade supports system connections to either 2- wire (four lead, tip/ring) or 4-wire (ei...

  • Page 256

    Issue 7.0 univerge sv8100 4 - 106 installing the sv8100 blades two blade status leds two straps and one switch per circuit to determine the circuit type table 4-60 cd-4odtb maximum upgrade capacities provides the maximum capacities for the odt blades when they are upgraded. 5.8.2 installation 1. Set...

  • Page 257

    Univerge sv8100 issue 7.0 system hardware manual 4 - 107 5.8.3 led indications led indications for the cd-4odtb are listed in table 4-61 cd-4odtb led indications . Each led is listed with its associated function and led and operational status. Refer to figure 4-32 cd-4odtb blade on page 4-105 for th...

  • Page 258

    Issue 7.0 univerge sv8100 4 - 108 installing the sv8100 blades table 4-62 cd-4odtb rj-61 cable connector pin-outs rj-61 cable connector – 2-wire e&m, cn1a~cn1d pin no. Connection description 1 — not used 2 m control signal to trunk 3 — not used 4 r voice signal both ways 5 t voice signal both ways 6...

  • Page 259

    Univerge sv8100 issue 7.0 system hardware manual 4 - 109 5.8.5 connections figure 4-33 voice signal connection for type i and v on page 4-109 and figure 4-34 control signal connection on page 4-110 show the signaling methods for circuit types. Figure 4-33 voice signal connection for type i and v.

  • Page 260

    Issue 7.0 univerge sv8100 4 - 110 installing the sv8100 blades figure 4-34 control signal connection.

  • Page 261

    Univerge sv8100 issue 7.0 system hardware manual 4 - 111 s ection 6 o ptional b lades 6.1 cd-pvaa (conference bridge) (future enhancement) 6.1.1 description the packet voice application, cd-pvaa blade is an optional interface that supports application packages (univerge multimedia conference bridge,...

  • Page 262

    Issue 7.0 univerge sv8100 4 - 112 installing the sv8100 blades a digital signal processor/voice processing section handles the following functions: dtmf detection dtmf generation general tone detection automatic gain control (agc) basic support package each blade installed with the cnf or ivr packag...

  • Page 263

    Univerge sv8100 issue 7.0 system hardware manual 4 - 113 fast flash: board is in sync with the chassis and operating normally busy led – red on: application problem compactflash card activity led – red compactflash card activity led is controlled by the ide controller and indicates read/write activi...

  • Page 264

    Issue 7.0 univerge sv8100 4 - 114 installing the sv8100 blades 6.2 cd-rtb (4-port ) 6.2.1 description the router blade is a 4-port switching hub which complies with the ethernet specification for both 100base-tx and 10base-t. This blade is compatible in lan applications using 10mbps and 100mbps. All...

  • Page 265

    Univerge sv8100 issue 7.0 system hardware manual 4 - 115 mdi/mdi-x auto crossover tag vlan based on ieee802.1q port-base vlan port mirroring pppoe client multi-protocol bridge rip/ripv2/ospfv2/bgp4 policy routing dhcp nat/napt sip-nat ipnp nat traversal dns proxy ntp/sntp qos (pq, cbq, llq, shaping)...

  • Page 266

    Issue 7.0 univerge sv8100 4 - 116 installing the sv8100 blades terminal, the blade may not be able to detect the difference between straight cable and cross-cable automatically. If auto-crossover is not functioning, use straight cable for that terminal connection. Table 4-63 cd-rtb maximum upgrade c...

  • Page 267

    Univerge sv8100 issue 7.0 system hardware manual 4 - 117 6.3 cd-etia (gigabit poe switch) 6.3.1 description the cd-etia blade is a managed 8-port gigabit ethernet poe switch. Ports 1 and 8 are the default uplink ports. All the user management and stacking is based on this setup. This blade provides:...

  • Page 268

    Issue 7.0 univerge sv8100 4 - 118 installing the sv8100 blades 802.1p priority queuing port mirroring 802.3x flow control independent vlan learning support tcp/ip networking stack multi-unit stacking (multiple blades in a system are managed from the same user interface) dynamic poe control (allows s...

  • Page 269

    Univerge sv8100 issue 7.0 system hardware manual 4 - 119 6.3.2.2 cd-cp00ip address assignment the gswu main board will be provided with an ip address from the back plane cpu during the initialization sequence. The provision of an ip address from the back plane will identify the main board. If during...

  • Page 270

    Issue 7.0 univerge sv8100 4 - 120 installing the sv8100 blades 2. User removes add-on board and moves it to slot 6. The re-inserted board automatically gets ports 17 ~ 24 (9 ~ 16 are unavailable). . User can erase the ports 9 ~ 16. . Then reinsert the board in slot 6 to get ports 9 ~ 16. 3. User rel...

  • Page 271: - - Notes - -

    Univerge sv8100 issue 7.0 system hardware manual 4 - 121 - - notes - -.

  • Page 272

    Issue 7.0 univerge sv8100 4 - 122 installing the sv8100 blades.

  • Page 273

    System hardware manual 5 - 1 chapter 5 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals s ection 1 g eneral d escription this chapter provides information about the dt300/dt700 series digital and ip terminals in addition to the single line telephones, cordless telephones an...

  • Page 274

    Issue 7.0 univerge sv8100 5 - 2 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals the dt300/dt700 series offers a line up of modular telephones. This modular design allows the telephones to be upgraded and customized. Optional lcd panels, keypads, handset cradles, face plate...

  • Page 275

    Univerge sv8100 issue 7.0 system hardware manual 5 - 3 itl-320c-1 (bk) tel 3 –— 3 3 –— –— 3 digital terminals: dtl-2e-1 (bk) tel –— –— –— –— –— –— –— dtl-6de-1 (bk) tel –— –— –— –— –— –— –— dtl-8ld(bk)/(wh) tel 3 3 –— 3 3 3 –— dtl-12bt-1 (bk) tel –— –— –— –— –— –— –— dtl-12d-1 (bk)/(wh) tel 3 3 –— 3...

  • Page 276

    Issue 7.0 univerge sv8100 5 - 4 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals itl-12dg-3 (bk) tel 3 –— –— 3 –— 3 itl-12pa-1 (bk) tel 3 –— 3 3 3 3 itl-24d-1 (bk)/(wh) tel 3 –— 3 –— 3 3 itl-32d-1 (bk)/(wh) tel 3 –— 3 –— 3 –— itl-320c-1 (bk) tel 3 –— –— –— 3 3 digital termi...

  • Page 277

    Univerge sv8100 issue 7.0 system hardware manual 5 - 5 table 5-4 terminal and tenkey kit compatibility terminal tenkey kit bs(f)-l bs(s)-l bs(acd)-l bs(braille)-l bs(retro)-l ip terminals: itl-2e-1 (bk) tel –— –— –— –— 3 itl-6de-1 (bk) tel –— –— –— –— 3 itl-8lde-1 (bk) tel –— –— –— –— –— itl-8ld-1 (...

  • Page 278

    Issue 7.0 univerge sv8100 5 - 6 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals table 5-5 terminal and optional equipment compatibility terminal equipment psa-l wm-l * panel-l ip terminals: itl-2e-1 (bk) tel –— 3 3 itl-6de-1 (bk) tel –— 3 3 itl-8lde-1 (bk) tel –— 3 3 itl-8...

  • Page 279: Dt300 S

    Univerge sv8100 issue 7.0 system hardware manual 5 - 7 s ection 2 dt300 s eries d igital m ultiline t erminals the dt300 series offers a new exciting line up of digital telephones. These telephones (except economy), have a modular design that allows the telephones to be upgraded and customized. Opti...

  • Page 280

    Issue 7.0 univerge sv8100 5 - 8 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals figure 5-1 dtl-2e-1 tel.

  • Page 281

    Univerge sv8100 issue 7.0 system hardware manual 5 - 9 2.1.2 dtl-6de-1 (bk) tel this digital economy multiline terminal has six line keys with display and is available in black only. The terminal features: non-modular design four step adjustable base half-duplex speaker phone six line keys (red, gre...

  • Page 282

    Issue 7.0 univerge sv8100 5 - 10 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals backlit 10-key dial pad for easy viewing full-duplex handsfree operation 2.1.4 dtl-12bt-1 (bk) tel this digital value multiline terminal has 12 line keys and is available in black only. The te...

  • Page 283

    Univerge sv8100 issue 7.0 system hardware manual 5 - 11 2.1.5 dtl-12d-1 (bk) tel/dtl-12d-1 (wh) tel this digital value multiline terminal has 12 line keys and is available in both black and white. The terminal features: modular design four step adjustable base full-duplex speaker phone eight line ke...

  • Page 284

    Issue 7.0 univerge sv8100 5 - 12 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 2.1.6 dtl-12pa-1 (bk) tel this digital value multiline terminal with analog power failure adapter has 12 line keys and is available in black only. The terminal features: modular design four st...

  • Page 285

    Univerge sv8100 issue 7.0 system hardware manual 5 - 13 2.1.7 dtl-24d-1 (bk) tel/dtl-24d-1 (wh) tel this digital value multiline terminal has 24 line keys and is available in both black and white. The terminal features: modular design four step adjustable base full-duplex speaker phone eight line ke...

  • Page 286

    Issue 7.0 univerge sv8100 5 - 14 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 2.1.8 dtl-32d-1 (bk) tel/dtl-32d-1 (wh) tel this digital value multiline terminal has 32 line keys (24 line keys plus eight line key lk unit) and is available in both black and white. The term...

  • Page 287

    Univerge sv8100 issue 7.0 system hardware manual 5 - 15 figure 5-8 dtl-32d-1 tel.

  • Page 288: Dt700 S

    Issue 7.0 univerge sv8100 5 - 16 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals s ection 3 dt700 s eries ip m ultiline t erminals the dt700 series offers a new exciting line up of ip telephones. These telephones (except economy), have a modular design that allows the tele...

  • Page 289

    Univerge sv8100 issue 7.0 system hardware manual 5 - 17 3.1.2 itl-6de-1 (bk) tel this ip economy multiline terminal has six line keys with display and is available in black only. The terminal features: non-modular design four step adjustable base remote login and maintenance full-duplex speaker phon...

  • Page 290

    Issue 7.0 univerge sv8100 5 - 18 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 224 x 96 dot matrix gray scale backlit lcd ieee 802.3af compliant xml open interface (limited) 10 base-t/100 base-tx network interface wide band handset 3.1.4 itl-8ld-1 (bk) tel/itl-8ld-1 (wh)...

  • Page 291

    Univerge sv8100 issue 7.0 system hardware manual 5 - 19 backlit lcd 3.1.5 itl-12d-1 (bk) tel/itl-12d-1 (wh) tel this ip value multiline terminal has 12 line keys and is available in both black and white. The terminal features: modular design four step adjustable base full-duplex speaker phone protec...

  • Page 292

    Issue 7.0 univerge sv8100 5 - 20 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals backlit lcd 3.1.6 itl-12cg-3 (bk) tel this ip value multiline terminal has 12 line keys and is available in black only. The terminal features: usb connection (usb 2.0, 5v/500ma supply) modular...

  • Page 293

    Univerge sv8100 issue 7.0 system hardware manual 5 - 21 figure 5-14 itl-12cg-3 tel 3.1.7 itl-12dg-3 (bk) tel this ip value multiline terminal has 12 line keys and is available in black only. The terminal features: usb connection (usb 2.0, 5v/500ma supply) modular design four-step adjustable base ful...

  • Page 294

    Issue 7.0 univerge sv8100 5 - 22 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 10 base-t/100 base-tx/1000 base-t network interface figure 5-15 itl-12dg-3 tel 3.1.8 itl-12pa-1 (bk) tel this ip value multiline terminal with analog power failure adapter has 12 line keys and...

  • Page 295

    Univerge sv8100 issue 7.0 system hardware manual 5 - 23 backlit lcd psa adapter for power failure 3.1.9 itl-24d-1 (bk) tel/itl-24d-1 (wh) tel this ip value multiline terminal has 24 line keys and is available in both black and white. The terminal features: modular design four step adjustable base fu...

  • Page 296

    Issue 7.0 univerge sv8100 5 - 24 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 3.1.10 itl-32d-1 (bk) tel/itl-32d-1 (wh) tel this ip value multiline terminal has 32 line keys (24 line keys plus an eight line key lk unit) and is available in both black and white. The termi...

  • Page 297

    Univerge sv8100 issue 7.0 system hardware manual 5 - 25 3.1.11 itl-320c-1 (bk) tel this ip multiline terminal features a large color touch panel lcd and is available in black only. The terminal features: modular design four step adjustable base full-duplex speaker phone protection button seven color...

  • Page 298

    Issue 7.0 univerge sv8100 5 - 26 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals figure 5-19 itl-320c-1 tel.

  • Page 299

    Univerge sv8100 issue 7.0 system hardware manual 5 - 27 s ection 4 i nstall m ultiline t erminals 4.1 connecting the dt300 series multiline terminal to the system this instruction applies to all dt300 series multiline terminals. 1. Plug the telephone cord into the modular jack on the bottom side of ...

  • Page 300

    Issue 7.0 univerge sv8100 5 - 28 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 2. Lead the line and handset cables through the applicable grooves. 4.2 applying power to the dt700 multiline terminals the dt700 terminals support two different methods to power the terminal:...

  • Page 301

    Univerge sv8100 issue 7.0 system hardware manual 5 - 29 4.3 connecting the ip multiline terminal to the network and pc these instructions for connecting an ip multiline terminal to the network and pc apply to dt700 multiline terminals. Refer to figure 5-22 ip terminal connector locations . 1. Connec...

  • Page 302

    Issue 7.0 univerge sv8100 5 - 30 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 4.4 adjusting the lcd on the multiline terminal dt300/dt700 series display multiline terminals have an adjustable liquid crystal display (lcd). The lcd can be adjusted by pulling up or pushing...

  • Page 303

    Univerge sv8100 issue 7.0 system hardware manual 5 - 31 4.5 installing line key kit (12lk-l kit ) the 12lk-l kit provides twelve additional buttons to itl or dtl multiline terminals. The 12lk-l kit kit: mounts directly to top side of terminal supports red and green led colors 4.5.1 installing the 12...

  • Page 304

    Issue 7.0 univerge sv8100 5 - 32 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 4. Lift and remove the desi sheet. 5. Press the right end of the line key placeholder and lift to remove (refer to figure 5-28 removing the line key placeholder on page 5-33 ). Figure 5-26 rem...

  • Page 305

    Univerge sv8100 issue 7.0 system hardware manual 5 - 33 6. Install the 12lk-l kit and press down until click is heard. Figure 5-28 removing the line key placeholder figure 5-29 installing the 12lk-l kit press here then lift 12lk-l kit.

  • Page 306

    Issue 7.0 univerge sv8100 5 - 34 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 7. If desired, print and install the new desi sheet. 8. Install the supplied line key panel (refer to figure 5-31 installing the line key panel ). 9. Install the side panel. 10. Connect the li...

  • Page 307

    Univerge sv8100 issue 7.0 system hardware manual 5 - 35 4.5.2 configuring the digital telephone for the correct number of line keys 1. With the telephone not plugged in and the handset on-hook, press the 4 and 6 buttons on the numbered keypad and connect the telephone cable. . This places the teleph...

  • Page 308

    Issue 7.0 univerge sv8100 5 - 36 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 5. Press soft key 2 for key kit type. 6. Select the type of keypad kit being used by pressing the up/ down key. 7. Press soft key 4 for next. 8. Select the type of line key kit being used by p...

  • Page 309

    Univerge sv8100 issue 7.0 system hardware manual 5 - 37 10. Continue pressing soft key 4 to exit (exit-exit-save). The terminal will reset automatically. 4.6 installing the directory card on the multiline terminal a directory card can be attached to dt300/dt700 series multiline terminals. The direct...

  • Page 310

    Issue 7.0 univerge sv8100 5 - 38 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 4.7 installing a numbered keypad on the multiline terminal the bs( )-l kits are keypad sets, which can be installed on a multiline terminal replacing the standard numbered keypad. The d term s...

  • Page 311

    Univerge sv8100 issue 7.0 system hardware manual 5 - 39 bs (retro)-l kit the optional retro keypad (in black or white), is compatible with the d term series i telephone, allowing the terminal to be used with the ipk ii, ipc 500 and ips multiline terminals. Figure 5-34 standard numbered keypad figure...

  • Page 312

    Issue 7.0 univerge sv8100 5 - 40 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 4.7.1 installing the numbered keypad on a multiline terminal 1. Remove the plastic panels. (refer to paragraph figure 5-36 remove plastic panels .) 2. Pull down on the tab and lift the numbere...

  • Page 313

    Univerge sv8100 issue 7.0 system hardware manual 5 - 41 3. Slide the replacement numbered keypad into the grooves located on the inside of the telephone, then press down on the keypad to snap it into place. See figure 5-38 install new numbered keypad into dt300/dt700 series terminal . 4. Insert the ...

  • Page 314

    Issue 7.0 univerge sv8100 5 - 42 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 4.7.2 configuring the digital telephone for the numbered keypad 1. With the telephone not plugged in and the handset on-hook, press the 4 and 6 buttons on the numbered keypad and connect the t...

  • Page 315

    Univerge sv8100 issue 7.0 system hardware manual 5 - 43 2. At the login screen, enter the user name (default = admin) and password (default = 6633222) and press the ok soft key. 3. Press soft key 3 for maintenance setting. 4. Press soft key 4 for adjust. 5. Press soft key 2 for key kit type. 6. Sele...

  • Page 316

    Issue 7.0 univerge sv8100 5 - 44 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 9. Press soft key 4 for ok to complete. 10. Continue pressing soft key 4 to exit (exit-exit-save). The terminal will reset automatically. 4.8 adjusting the height on the multiline terminal the...

  • Page 317

    Univerge sv8100 issue 7.0 system hardware manual 5 - 45 4.9 removing or installing the tilt legs on the multiline terminal the tilt legs can be removed or installed on the dt300/dt700 series multiline terminal. 4.9.1 remove tilt legs 1. Place the telephone on a flat surface (button side down). 2. Se...

  • Page 318

    Issue 7.0 univerge sv8100 5 - 46 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 4. Lift and remove the tilt legs. 4.9.2 install tilt legs 1. Place the telephone on a flat surface (button side down). 2. Lay the adjustable tilt legs on top of the telephone. See figure 5-43 ...

  • Page 319

    Univerge sv8100 issue 7.0 system hardware manual 5 - 47 5. Snap legs together and adjust to desired height. See figure 5-45 adjust height of dt300/dt700 series terminal ). Figure 5-44 connecting the tilt legs figure 5-45 adjust height of dt300/dt700 series terminal.

  • Page 320

    Issue 7.0 univerge sv8100 5 - 48 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 4.10 wall mounting the multiline terminal you can wall mount a dt300/dt700 series connection multiline terminal using the base cover or an optional wall mount unit. A wall mount unit must be u...

  • Page 321

    Univerge sv8100 issue 7.0 system hardware manual 5 - 49 4.10.1.2 wall mounting the multiline terminal 1. Plug line cord in the wall receptacle. Leave about eight inches of cord and bundle the rest as shown in figure 5-48 bundling the line cord . 2. Ensure the tilt legs are in the flat (unused positi...

  • Page 322

    Issue 7.0 univerge sv8100 5 - 50 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 5. Push spare line cord behind the multiline terminal. 4.10.1.3 removing the multiline terminal from the wall mounted base plate. To remove the multiline terminal, push up on the telephone unt...

  • Page 323

    Univerge sv8100 issue 7.0 system hardware manual 5 - 51 4.10.1.4 wall mounting the base on a switch box 1. Locate the screw holes on the base and hang the cover over the screws on the switch box as illustrated in figure 5-52 wall mounting base on switch box . 2. Hang the multiline terminal on the ba...

  • Page 324

    Issue 7.0 univerge sv8100 5 - 52 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals s ection 5 m ultiline t erminals o ptional e quipment 5.1 dt300/dt700 series terminal options the following chart provides a quick overview of the options available with the dt300/dt700 series...

  • Page 325

    Univerge sv8100 issue 7.0 system hardware manual 5 - 53 5.2 dt300/dt700 series optional terminal equipment 5.2.1 8lk-l (bk) unit/8lk-l (wh) unit provides eight additional line keys to itl or dtl terminals (except economy). The unit features: mounts directly to right side of terminal supports red and...

  • Page 326

    Issue 7.0 univerge sv8100 5 - 54 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 3. Pry the side panel from the multiline terminal. 4. Return the multiline terminal to the buttons side up position. 5. Fit the projections on the side of the 8lk-l unit into the guide holes o...

  • Page 327

    Univerge sv8100 issue 7.0 system hardware manual 5 - 55 8. Open the small door covering the side option connectors by pulling the cover handle to the front. 9. Connect the cable from the 8lk-l unit to the side option connector (see figure 5-57 install the 8lk-l unit cable ) on the multiline terminal...

  • Page 328

    Issue 7.0 univerge sv8100 5 - 56 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 5.2.2.1 installing the 8lkd (ld)-l unit 1. Turn multiline terminal upside down. . Only one 8lkd (ld)-l unit can be attached to the dtl multiline terminal. 2. Pry the side panel from the multil...

  • Page 329

    Univerge sv8100 issue 7.0 system hardware manual 5 - 57 3. Remove the screw (refer to figure 5-59 remove side panel from multiline terminal on page 5-56 ). 4. Carefully, return the multiline terminal to the buttons side up position. 5. Remove the soft keys and line key kit from the telephone. 6. Gen...

  • Page 330

    Issue 7.0 univerge sv8100 5 - 58 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 9. Align the projections on the bottom of the 8lkd (ld)-l unit into the guide holes on top of the multiline terminal. 10. Slide the 8lkd (ld)-l unit toward the keypad buttons until snug (refer...

  • Page 331

    Univerge sv8100 issue 7.0 system hardware manual 5 - 59 11. Holding the lcd in place, turn the multiline terminal button side down. 12. Install the screw (refer to figure 5-63 install screw ). 13. Attach the side panel to the side of the 8lkd (ld)-l unit (refer to figure 5-69 install screw on page 5...

  • Page 332

    Issue 7.0 univerge sv8100 5 - 60 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 5.2.3.1 installing the 8lki (ld)-l unit 1. Turn multiline terminal upside down. . Only one 8lki (ld)-l unit can be attached to the itl multiline terminal. 2. Pry the side panel from the multil...

  • Page 333

    Univerge sv8100 issue 7.0 system hardware manual 5 - 61 3. Remove the screw (refer to figure 5-65 remove side panel from multiline terminal on page 5-60 ). 4. Carefully, return the multiline terminal to the buttons side up position. 5. Remove the soft keys and line key kit from the telephone. 6. Gen...

  • Page 334

    Issue 7.0 univerge sv8100 5 - 62 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 9. Align the projections on the bottom of the 8lki (ld)-l unit into the guide holes on top of the multiline terminal (refer to figure 5-67 ribbon cable installed ). 10. Slide the 8lki (ld)-l u...

  • Page 335

    Univerge sv8100 issue 7.0 system hardware manual 5 - 63 11. Holding the lcd in place, turn the multiline terminal button side down. 12. Install screw (refer to figure 5-69 install screw ). 13. Attach the side panel to the side of the 8lki (ld)-l unit (refer to figure 5-69 install screw ). 14. Return...

  • Page 336

    Issue 7.0 univerge sv8100 5 - 64 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals keep the following in mind when installing dss consoles: a 60-button dss console requires a separate digital station port when pairing with a digital keyset. For ip terminals, the first consol...

  • Page 337

    Univerge sv8100 issue 7.0 system hardware manual 5 - 65 3. Pry the side panel from the multiline terminal. 4. Turn the multiline terminal button side up. 5. Fit the projections of the supplied bracket into the side of the multiline terminal. 6. Attach the bracket with three supplied screws. Figure 5...

  • Page 338

    Issue 7.0 univerge sv8100 5 - 66 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 7. Carefully push the serial cable into the serial cable groove (itl, dt700 only). 8. Using the guides, slide the dcl-60-1 onto the installed bracket (refer to figure 5-73 press serial cable i...

  • Page 339

    Univerge sv8100 issue 7.0 system hardware manual 5 - 67 10. Open the small door covering the side option connectors by pulling the cover latch toward you (refer to figure 5-75 serial cable installed , itl, dt700 only). 11. Connect the cable from the dcl-60-1 console to the side option connector on t...

  • Page 340

    Issue 7.0 univerge sv8100 5 - 68 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 18. Complete the installation by reattaching both plastic panels to the front of the multiline terminal. 5.2.5 lcd (bl)-l (bk) unit/lcd (bl)-l (wh) unit the lcd (bl)-l unit is an optional lcd ...

  • Page 341

    Univerge sv8100 issue 7.0 system hardware manual 5 - 69 5.2.6 panel( )-l unit optional plastic color side panels that allow users to customize the itl/dtl terminals. The following colors are available for the base (all), vlcd (value lcd) and slcd (sophi lcd) terminals: silver (original) red blue cle...

  • Page 342

    Issue 7.0 univerge sv8100 5 - 70 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 3. Attach the wm-l unit to the wall using four screws (refer to figure 5-80 attach the wm-l unit to wall ). 4. Align the four cutouts with the four tabs on the wm-l unit (refer to figure 5-81 ...

  • Page 343

    Univerge sv8100 issue 7.0 system hardware manual 5 - 71 5. Push down on telephone until the wm-l unit snaps into place (refer to figure 5-82 wm-l unit installed ). 5.2.8 release the wm-l unit 1. To release the telephone from the wm-l unit, press the release button and push the telephone up (refer to...

  • Page 344

    Issue 7.0 univerge sv8100 5 - 72 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 5.2.9 wm-l unit attached to wall plate the wm-l unit (wall mount unit) is used to attach any dt300/ dt700 series multiline terminal to the wall plate this unit connects to the back side of the...

  • Page 345

    Univerge sv8100 issue 7.0 system hardware manual 5 - 73 5. Push up on the wm-l unit until it snaps into place (refer to figure 5-86 wm-l unit installed ). Figure 5-85 cutouts for wm-l unit figure 5-86 wm-l unit installed cutouts cutouts.

  • Page 346

    Issue 7.0 univerge sv8100 5 - 74 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 6. Align the two holes on the back of the wm-l unit with the two screws on the wall plate and slide downward (refer to figure 5-87 mount multiline terminal wall on wall plate ). . Because of s...

  • Page 347

    Univerge sv8100 issue 7.0 system hardware manual 5 - 75 s ection 6 o ptional h andsets 6.1 itl / dtl ptm handset the push to mute (ptm) handset has a single-pole, single throw switch that must be continuously held down to provide local mute. These replacement handsets for itl/dtl terminals help to e...

  • Page 348

    Issue 7.0 univerge sv8100 5 - 76 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 6.3 utr-1-1 usb handset the nec usb telephone can be plugged directly into a pc usb port, enabling the high quality voice input and output capabilities of a standard desktop telephone. By conn...

  • Page 349

    Univerge sv8100 issue 7.0 system hardware manual 5 - 77 6.3.3 wall mounting the utr-1-1 usb handset can be mounted on the wall using a wall plate or two screws. Align the two holes on the back of the utr-1-1 and slide down onto the wall plate or screws. . Because of strength variation in switch boxe...

  • Page 350

    Issue 7.0 univerge sv8100 5 - 78 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals s ection 7 b luetooth c ordless h andset 7.1 bluetooth cordless handset (bch) interface this optional interface allows the multiline terminal user to use bluetooth technology to provide a cord...

  • Page 351

    Univerge sv8100 issue 7.0 system hardware manual 5 - 79 7.2 selecting a location before choosing a location for your new telephone, consider these important guidelines: if multiple cordless terminals are installed, keep their bluetooth cradles at least 3.3 feet (1meter) apart from one another. If th...

  • Page 352

    Issue 7.0 univerge sv8100 5 - 80 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 7.3 controls and indicators controls and indicators can be found in figure 5-94 bluetooth cradle controls and indicators or figure 5-95 bluetooth handset controls and indicators on page 5-81 ....

  • Page 353

    Univerge sv8100 issue 7.0 system hardware manual 5 - 81 figure 5-95 bluetooth handset controls and indicators.

  • Page 354

    Issue 7.0 univerge sv8100 5 - 82 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 7.4 installing the bluetooth cordless handset the bch-l (bk) unit is an optional device that transforms the standard multifunctional telephone into a cordless terminal. This section explains h...

  • Page 355

    Univerge sv8100 issue 7.0 system hardware manual 5 - 83 7. Remove the side panel. 8. Disconnect serial connection cord from terminal body. Leave cord connected to the cradle unit. 9. Push the latch to the right to unlock the cradle unit. Then push the cradle unit forward to separate it from the term...

  • Page 356

    Issue 7.0 univerge sv8100 5 - 84 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 10. Insert the cradle connecting cable of the bluetooth cradle (btc) into the unit connector. 11. Fit the projections on the side of the bluetooth cradle into the guide holes on the side of th...

  • Page 357

    Univerge sv8100 issue 7.0 system hardware manual 5 - 85 14. Remove the connector cover (rubber) from the bottom of the multiline terminal. 15. Insert the lower claws of the bottom unit (see figure 5-102 installing the bottom unit ) into precut holes on the multiline terminal. 16. Align connector on ...

  • Page 358

    Issue 7.0 univerge sv8100 5 - 86 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 17. Push the latch to release the cover (see figure 5-103 stowing the bottom unit cable ). Stow the extra bottom unit connecting cable and close the cover. 18. Cut or trim the supplied coupled...

  • Page 359

    Univerge sv8100 issue 7.0 system hardware manual 5 - 87 21. Reinstall the legs, pushing upwards until both locks snap into place. 22. Set tilt legs to desired position. 23. Return the multiline terminal to the numbered keypad in the up position. 24. Connect the line cord and the ac adapter. 25. Plac...

  • Page 360

    Issue 7.0 univerge sv8100 5 - 88 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 7.4.2 wall mounting the bluetooth cradle clearances required for installing the bluetooth cradle are shown below. Avoid mounting the cradle on a plaster-board wall, but before mounting the cra...

  • Page 361

    Univerge sv8100 issue 7.0 system hardware manual 5 - 89 2. Remove the bluetooth hanger from the cradle. . With a screwdriver, pry from the bottom, and lift the handset hanger from the cradle. 3. Rotate the hanger top to bottom. Slide it downward in the hollow until it clicks into position. Figure 5-...

  • Page 362

    Issue 7.0 univerge sv8100 5 - 90 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 4. Turn multiline terminal upside down. 5. Lower the tilt leg to the first position (refer to figure 5-96 separate tilt leg from leg support ). 6. Hook the wall mount holes (c and d) on the ba...

  • Page 363

    Univerge sv8100 issue 7.0 system hardware manual 5 - 91 7.4.3 remove and replace handset battery the battery loaded in the bluetooth handset has a useful life of about two years, depending on how the handset is used. If the battery voltage diminishes quickly after the battery has been charged for a ...

  • Page 364

    Issue 7.0 univerge sv8100 5 - 92 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals s ection 8 b luetooth h ub a dapter 8.1 bluetooth hub adapter (bha) features the bha-l unit adapter connects a bluetooth device to a multiline terminal. The bha-l unit cannot be connected to t...

  • Page 365

    Univerge sv8100 issue 7.0 system hardware manual 5 - 93 5. Insert the lower claws of the bottom unit (see figure 5-115 installing the bha-l unit ) into precut holes on the multiline terminal. 6. Align connector on inside of bha-l unit and push down until unit snaps into place. 7. Set tilt legs to de...

  • Page 366

    Issue 7.0 univerge sv8100 5 - 94 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 8.1.2 pairing a bluetooth device and multiline terminal (bluetooth installed) access the bluetooth screen from a multiline terminal menu and register the bluetooth headset with the bha-l unit....

  • Page 367

    Univerge sv8100 issue 7.0 system hardware manual 5 - 95 8.1.2.4 connecting the paired device enable the bluetooth device. Select [2. Enable] in the connection screen. 8.1.2.5 unpairing to unpair a paired the bluetooth device, select the device in the [delete] screen. 8.1.2.6 visibility setting set w...

  • Page 368

    Issue 7.0 univerge sv8100 5 - 96 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 8.1.2.7 bt information you can view the following kinds of information about the bha-l unit: firmware and hardware versions. Bluetooth module information and standard. Installed profile versio...

  • Page 369

    Univerge sv8100 issue 7.0 system hardware manual 5 - 97 s ection 9 s ingle l ine t elephone 9.1 installing the slt adapter the single line telephone adapter provides an interface for single line telephones and other similar devices from an esi channel. This adapter can be connected to any esi port. ...

  • Page 370

    Issue 7.0 univerge sv8100 5 - 98 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 9.2 wall-mounting the slt adapter 1. Unplug the two line cords from the slt adapter. 2. Remove the two screws from the front of the slt adapter. 3. Lift the cover off the adapter. Figure 5-123...

  • Page 371

    Univerge sv8100 issue 7.0 system hardware manual 5 - 99 4. Using the two screws provided with the slt adapter, attach the back cover to the desired location. 5. Replace the front cover and the two screws removed in step 2. 6. Plug the two modular line cords back into the slt adapter which were remov...

  • Page 372: Dect (Dtl-8R-1)

    Issue 7.0 univerge sv8100 5 - 100 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals s ection 10 d term ® c ordless dect (dtl-8r-1) dtl-8r-1 is a cordless telephone that is adapted for digital nec pbx (private branch exchange. It is designed for use in the office environment....

  • Page 373

    Univerge sv8100 issue 7.0 system hardware manual 5 - 101 10.1 specifications the univerge sv8100 complies with fcc and ic part 15. General base unit figure 5-127 system overview rohs yes frequency 1.9g (1880 ~ 1900 mhz) audio process digital (adpcm) operating temperature 0 ⋅ ~ +50⋅ c (+32⋅ f to +122...

  • Page 374

    Issue 7.0 univerge sv8100 5 - 102 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals handset battery charger 10.2 battery safety q this equipment contains a rechargeable nickel-metal hydride battery. Q do not short-circuit the battery. Q do not charge the rechargeable nickel-...

  • Page 375

    Univerge sv8100 issue 7.0 system hardware manual 5 - 103 q charge the battery pack provided with or identified for use with this product only in accordance with the instructions and limitations specified in the instruction manual provided for this product. Q observe proper polarity orientation betwe...

  • Page 376

    Issue 7.0 univerge sv8100 5 - 104 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals risks. Incorrect reassembly can cause electric shock when the appliance is subsequently used. Q unplug this product from the wall outlet and refer servicing to qualified service personnel und...

  • Page 377

    Univerge sv8100 issue 7.0 system hardware manual 5 - 105 changes or modifications to this product not expressly approved by nec unified solutions, or operation of this product in any way other than as detailed by this manual, could void your authority to operate this product..

  • Page 378

    Issue 7.0 univerge sv8100 5 - 106 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals range nominal values of the dect system are: q 164 feet (50 meters) – indoor q 984 feet (300 meters) – outdoor the telephone is designed to achieve a maximum range of up to 350 feet (107 metr...

  • Page 379

    Univerge sv8100 issue 7.0 system hardware manual 5 - 107 the dtl-8r-1 is limited to five rf channels. The rf channel is changed automatically to find the best channel. Depending on your environment, the maximum number of cordless devices used without interference varies. Multiple base and handset un...

  • Page 380

    Issue 7.0 univerge sv8100 5 - 108 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 1. Connect the cord from the telephone jack to the line in on the d term cordless dect. 2. Connect a qualified nec digital multiline terminal to the d term cordless dect. Figure 5-128 connect...

  • Page 381

    Univerge sv8100 issue 7.0 system hardware manual 5 - 109 10.8 applying power to the charging unit the unique design of the telephone allows the user to place the handset in the charging unit with or without the belt clip attached. The charging unit can charge a second battery with or without the han...

  • Page 382

    Issue 7.0 univerge sv8100 5 - 110 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 10.9 mounting the base to a standard wall plate the base unit is designed to be mounted on standard wall plate. To attach the wall mount stand to the base unit: 1. Slide the wall mount stand ...

  • Page 383

    Univerge sv8100 issue 7.0 system hardware manual 5 - 111 stand. 4. Plug one end of the short telephone cord (locally supplied) in the line jack on the base unit. Plug one end of the nec digital multiline terminal into the phone jack. Place the telephone cords inside the molded channels on the bottom...

  • Page 384

    Issue 7.0 univerge sv8100 5 - 112 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 5. Plug the other end of the short telephone cord into the modular wall jack in the center of the wall plate. 6. Place the base unit on the posts of the wall plate and push down until it is f...

  • Page 385

    Univerge sv8100 issue 7.0 system hardware manual 5 - 113 10.10 mounting the base directly to the wall if a standard wall plate is not available, mount the telephone directly on the wall. Before mounting the telephone, consider the following: m select a location away from electrical cables, pipes, or...

  • Page 386

    Issue 7.0 univerge sv8100 5 - 114 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 5. Place the base unit on the posts of the wall screws and push down until it is firmly seated. 6. Plug the other end of the short telephone cord into a telephone wall jack. 7. Plug the ac ad...

  • Page 387

    Univerge sv8100 issue 7.0 system hardware manual 5 - 115 10.11 wall mounting the charging unit the charging unit is also designed to be wall mounted. Before mounting the charging unit, consider the following: m select a location away from electrical cables, pipes, or other items behind the mounting ...

  • Page 388

    Issue 7.0 univerge sv8100 5 - 116 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 3. Place the charging unit on the posts of the wall screws and push down until it is firmly seated. 4. Plug the ac adapter into a standard 230 vac wall outlet. Refer to figure 5-141 placing t...

  • Page 389

    Univerge sv8100 issue 7.0 system hardware manual 5 - 117 2. To remove the clip, press the retaining clip in toward the belt clip blade and slide the clip up at the same time. 10.13 installing the handset battery pack before installing batteries, refer to d term ® cordless dect owner’s manual specifi...

  • Page 390

    Issue 7.0 univerge sv8100 5 - 118 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 2. Slide the battery pack down into the handset. . It may be necessary to remove the old battery at this time. 3. Replace the cover and slide it up until it latches onto the handset. 10.14 ch...

  • Page 391: Ml440/ap300 C

    Univerge sv8100 issue 7.0 system hardware manual 5 - 119 s ection 11 ml440/ap300 c ordless handset the ml440/ap300 chapter outlines the steps for connecting and mounting the base station, charging the battery and powering on the handset. 11.1 connecting the base station . If your network connection ...

  • Page 392

    Issue 7.0 univerge sv8100 5 - 120 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 2. Route the cable through the channel. Figure 5-148 install ap300 base station 3. Connect the other end of the cable to your tcp/ip network. When the base station powers on, the status led o...

  • Page 393

    Univerge sv8100 issue 7.0 system hardware manual 5 - 121 11.2 base station wall mounting installation . Ensure the wall can support the weight of the base station. 1. Hold the mounting plate in its final location and mark the screw locations on the plate as shown below. Figure 5-149 base station dim...

  • Page 394

    Issue 7.0 univerge sv8100 5 - 122 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 11.3 handset and charger figure 5-150 ml440 handset - front view on page 5-122 provides a front view of the handset. Figure 5-151 ml440 - handset charger on page 5-123 provides a to view of t...

  • Page 395

    Univerge sv8100 issue 7.0 system hardware manual 5 - 123 figure 5-151 ml440 - handset charger 11.4 charging the battery 1. Install the handset battery as shown. Figure 5-152 ml440 - handset battery installation remove the battery cover from the back of the handset. Insert the bottom of the battery i...

  • Page 396

    Issue 7.0 univerge sv8100 5 - 124 installing dt300/dt700 series (dtl/itl) digital and ip multiline terminals 2. Use the charger ac adapter to connect the charger’s ac jack to a standard electrical outlet. 3. Place the handset in th echarger with the display facing forward. The handset status led sho...

  • Page 397: Pgd(2)-U10 Adp

    System hardware manual 6 - 1 chapter 6 installing sv8100 optional equipment s ection 1 g eneral i nformation this chapter provides information for installing optional equipment, such as pgd(2)-u10 adps, background music, door boxes, dss consoles, d term vsr, external paging as well as other handsets...

  • Page 398

    Issue 7.0 univerge sv8100 6 - 2 installing sv8100 optional equipment the pgd(2)-u10 adp connects to any available digital extension port. The terminal connections made within the pgd(2)-u10 adp and the jumper settings determine what features are used for each circuit. 2.2 led indications 2.3 setting...

  • Page 399

    Univerge sv8100 issue 7.0 system hardware manual 6 - 3 1. Remove the screw from the front of the pgd(2)-u10 adp. 2. Using a screwdriver, break out the plastic piece covering the cable hole. 3. Set the s3 – s6 jumpers to the proper settings for the function to be used (refer to table 6-2 pgd(2)-u10 a...

  • Page 400

    Issue 7.0 univerge sv8100 6 - 4 installing sv8100 optional equipment table 6-2 pgd(2)-u10 adp s3 – s6 jumper settings channel 1 s3 s4 function led indication open open door box on when in use. Open short external paging speaker on when in use. Short open external ringer on when in use. Short short e...

  • Page 401

    Univerge sv8100 issue 7.0 system hardware manual 6 - 5 4. Strip one end of the cable to be connected to the control relay or door box so that approximately 1/4” (8 mm) of bare wire is exposed. 5. Insert the cable into the proper cn4 or cn5 location while holding down the lock button (holding down th...

  • Page 402

    Issue 7.0 univerge sv8100 6 - 6 installing sv8100 optional equipment figure 6-5 pgd(2)-u10 adp connection diagram.

  • Page 403

    Univerge sv8100 issue 7.0 system hardware manual 6 - 7 6. Repeat steps 4 and 5 for any additional connections required. 7. Replace the cover and tighten the screw to hold the cover in place. 8. If required for the function being used, insert the rca connectors into the cn2 (channel 1) and cn3 (chann...

  • Page 404

    Issue 7.0 univerge sv8100 6 - 8 installing sv8100 optional equipment 9. Install a modular jack for each pgd(2)-u10 adp. For each module, run one-pair 24 awg station cable from the cross-connect block to a modular jack. Ground the unused pair. 10. Terminate the extension leads to grn/red of the modul...

  • Page 405

    Univerge sv8100 issue 7.0 system hardware manual 6 - 9 fits best for your location. 14. The back of the pgd(2)-u10 adp has two key-hole type openings. Place the pgd(2)-u10 adp over the two screws and slide it down or over (depending on the positioning) to lock it in place. Figure 6-8 installing the ...

  • Page 406

    Issue 7.0 univerge sv8100 6 - 10 installing sv8100 optional equipment s ection 3 b ackground m usic 3.1 installing background music background music (bgm) sends music from a customer-provided music source to speakers in keysets. If an extension user activates it, bgm plays whenever the user’s extens...

  • Page 407

    Univerge sv8100 issue 7.0 system hardware manual 6 - 11 s ection 4 d oor b ox 4.1 installing a door box the door box is a self-contained, water-resistant, intercom unit typically used to monitor an entrance door. A visitor at the door can press the door box call button (like a door bell). The door b...

  • Page 408

    Issue 7.0 univerge sv8100 6 - 12 installing sv8100 optional equipment 8. Remove the back half of the door box and attach this mounting bracket to the wall with the two screws provided. 9. Connect the two-conductor station cable from the cn4 connectors within the pgd(2)-u10 adp to the door box termin...

  • Page 409

    Univerge sv8100 issue 7.0 system hardware manual 6 - 13 figure 6-11 setting the pgd(2)-u10 adp for a door box.

  • Page 410

    Issue 7.0 univerge sv8100 6 - 14 installing sv8100 optional equipment figure 6-12 installing a door box.

  • Page 411

    Univerge sv8100 issue 7.0 system hardware manual 6 - 15 s ection 5 e xternal p aging 5.1 external page two external page zone/door box circuits are provided by each pgd(2)-u10 adp installed. Each door box/external page circuit provides a dry relay contact. The cd-cp00 also provides a connection for ...

  • Page 412

    Issue 7.0 univerge sv8100 6 - 16 installing sv8100 optional equipment 4. Terminate the extension leads to grn/red of the modular jack. Terminate the unused leads to the jack. 5. Install bridging clips as required. 6. Plug a modular line cord from the mod jack to the cn1 connector on the pgd(2)-u10 a...

  • Page 413

    Univerge sv8100 issue 7.0 system hardware manual 6 - 17 s ection 6 e xternal p aging and d oor b ox /p age r elays 6.1 external page relays two external dry contact relays are available when a pgd(2)-u10 adp is installed which can be used to activate ancillary devices (i.E. Door unlock devices). The...

  • Page 414

    Issue 7.0 univerge sv8100 6 - 18 installing sv8100 optional equipment 6.2 door box /external page relay contacts 6.2.1 connecting a contact relay device to a door box/external page relay to connect a dry contact relay device to a door box/external page relay: to connect to the cd-cp00: 1. Connect an...

  • Page 415

    Univerge sv8100 issue 7.0 system hardware manual 6 - 19 s ection 7 e xternal r ecording s ystem /e xternal r inger 7.1 external recording system or external ringer the pgd(2)-u10 adp allows the connection of an external recording system or external ringer. With a customer-provided tape recorder, whe...

  • Page 416

    Issue 7.0 univerge sv8100 6 - 20 installing sv8100 optional equipment 7.2 installing an external recording system or external ringer to connect to the pgd(2)-u10 adp: 1. Make sure the jumper in the pgd(2)-u10 adp for the channel is set correctly. (refer to figure 6-4 pgd(2)-u10 adp jumper settings o...

  • Page 417

    Univerge sv8100 issue 7.0 system hardware manual 6 - 21 7.3 programming 10-03-01 : etu setup – terminal type (circuit 1) 10-03-06 : etu setup – terminal type (circuit 2) confirm that the pgd(2)-u10 adp has defined the circuit type as either type 7 for external ringer or 9 for acis. (if the pgd(2)-u1...

  • Page 418

    Issue 7.0 univerge sv8100 6 - 22 installing sv8100 optional equipment 11-08-01 : aci group pilot number assign pilot numbers to aci groups. When a user dials the pilot number, they reach an available aci software port within the group. Aspire s: aci groups 1-4 aspire: aci groups 1-16 11-12-50 : serv...

  • Page 419

    Univerge sv8100 issue 7.0 system hardware manual 6 - 23 15-12-01 : conversation recording destination for extensions - aci recording destination extension number use this option to assign the aci call recording destination on a per extension basis. The destination can be an aci port’s extension numb...

  • Page 420

    Issue 7.0 univerge sv8100 6 - 24 installing sv8100 optional equipment s ection 8 m usic s ources 8.1 music on hold the system can provide music on hold from either an internally synthesized source on the cd-cp00 or from an external source. The external moh can be a tuner, tape deck, cd player, etc. ...

  • Page 421

    Univerge sv8100 issue 7.0 system hardware manual 6 - 25 3. Install a modular jack for each pgd(2)-u10 adp. For each module, run one-pair 24 awg station cable from the cross-connect block to a modular jack. Ground the unused pair. 4. Terminate the extension leads to grn/red of the modular jack. Termi...

  • Page 422

    Issue 7.0 univerge sv8100 6 - 26 installing sv8100 optional equipment figure 6-17 pgd(2)-u10 adp connections.

  • Page 423

    Univerge sv8100 issue 7.0 system hardware manual 6 - 27 s ection 9 n ight m ode s election 9.1 night mode selector switch the night mode switch relay closes when the system detects either an open or closure on the misc block night sw terminals. Maximum 48v dc is output to the switch when open, and 7...

  • Page 424

    Issue 7.0 univerge sv8100 6 - 28 installing sv8100 optional equipment 10.1.1 removing the faceplate 1. Use the small notch at the lower right corner of the telephone, to lift the faceplate up. Each corner has a plastic locking pin which releases as the faceplate is lifted up. 10.1.2 replacing the fa...

  • Page 425

    Univerge sv8100 issue 7.0 system hardware manual 6 - 29 s ection 11 t elephone a dapters 11.1 using adapters the modular terminals can support the installation of one additional adapter underneath the terminal. These adapters provide the keyset different capabilities, depending on the adapter instal...

  • Page 426

    Issue 7.0 univerge sv8100 6 - 30 installing sv8100 optional equipment nec power supply poe-managed switch (bluefire 200/24) (in-line and spare pair detection) router blade (spare pair detection) cisco data switch – cdp supported (in-line and spare pair detection) in-line power adapter 11.2.1 conditi...

  • Page 427

    Univerge sv8100 issue 7.0 system hardware manual 6 - 31 when using center feed, set the sw1 switch located on the back of the adapter as follows: 11.2.2 installation 1. Set the sw1 switch on the ilpa-r adapter to the correct setting for the ethernet switch to which it is to be connected. 2. Set the ...

  • Page 428

    Issue 7.0 univerge sv8100 6 - 32 installing sv8100 optional equipment 3. Connect the nec voip telephone to the tel connector on the ilpa-r adapter with the lan cable provided with the adapter. If a customer-provided cable is used, the total length from the switch to the telephone should be less than...

  • Page 429

    Univerge sv8100 issue 7.0 system hardware manual 6 - 33 11.3 ada-l unit using the ada-l unit (ancillary device adapter) provides a recording jack connection from a telephone to an external tape recorder, speaker or pc. Both sides of the conversation are recorded. The adapter output is a 1/8” audio (...

  • Page 430

    Issue 7.0 univerge sv8100 6 - 34 installing sv8100 optional equipment 11.3.1 ada-l unit switch settings figure 6-23 ada-l unit shows the location of the switches. The dip switches (dsw) allow a technician to configure the unit for specific settings. To provide control to the recorder or to enable/di...

  • Page 431

    Univerge sv8100 issue 7.0 system hardware manual 6 - 35 11.3.2 installing the ada-l unit perform the following steps to connect the ada-l unit to the bottom option interface located underneath the dtl/itl multiline terminal. . Only one ada-l unit can be installed at a time. 1. Unplug the line cord f...

  • Page 432

    Issue 7.0 univerge sv8100 6 - 36 installing sv8100 optional equipment 4. Push the two stopper tabs through the slots to separate the tilt leg from the leg support. 5. Lay the tilt leg and the leg support flat to expose ada-l unit compartment. 6. Carefully pry loose the knockout covering the bottom o...

  • Page 433

    Univerge sv8100 issue 7.0 system hardware manual 6 - 37 11.3.3 ada-l unit connection 11.3.3.1 ada-l unit connection for recording only 1. Set the ada-l unit dsw switches (refer to figure 6-23 ada-l unit on page 6-34 ). 2. Using the mini-plug connection cord, connect the the ada-l unit out jack to th...

  • Page 434

    Issue 7.0 univerge sv8100 6 - 38 installing sv8100 optional equipment 11.3.3.2 ada-l unit connection for sending recorded calls to the telephone 1. Set the ada-l unit dsw switches (see figure 6-23 ada-l unit on page 6-34 ). 2. Using the mini-plug connection cord, connect the the ada-l unit in jack t...

  • Page 435

    Univerge sv8100 issue 7.0 system hardware manual 6 - 39 when installing or removing the adapters, the telephone should be unplugged from the system. The apr-l unit supports reverse-polarity, message waiting lamping, or caller id. . Note: if the apr-l unit is configured with the same extension extens...

  • Page 436

    Issue 7.0 univerge sv8100 6 - 40 installing sv8100 optional equipment impedance (factory setting is 1). 11.4.2 installing the apr-l unit perform the following to connect the apr-l unit to the bottom option interface located underneath the dtl multiline terminal. . Only one apr-l unit can be installe...

  • Page 437

    Univerge sv8100 issue 7.0 system hardware manual 6 - 41 7. Using the exposed bottom option interface as a guide, install the apr-l unit in the bottom of the dtl multiline terminal. Push down until left and right tabs are seated (refer to figure 6-32 install apr-l unit ). 8. Return tilt leg to origin...

  • Page 438

    Issue 7.0 univerge sv8100 6 - 42 installing sv8100 optional equipment 12. Plug the end of the line cord for the analog device which has the ferrite bead closest to it into the jack on the adapter. Connect the opposite end to the analog device. 13. To determine the apr analog extension number. . . 10...

  • Page 439

    Univerge sv8100 issue 7.0 system hardware manual 6 - 43 11.5 psa-l (bk) unit / psa-l (wh) unit the psa-l unit (power save adapter), an optional adapter for the itl/dtl terminals, is used with ip telephones to make or receive a call using the public switched telephone network (pstn) when a call canno...

  • Page 440

    Issue 7.0 univerge sv8100 6 - 44 installing sv8100 optional equipment 11.5.1 installing the psa-l adapter 1. Turn multiline terminal upside down. 2. Unplug the line cord and handset cord from the keyset. . Only one psa-l unit can be attached to the dtl/itl multiline terminal. 3. Lower the tilt leg t...

  • Page 441

    Univerge sv8100 issue 7.0 system hardware manual 6 - 45 4. Push the two stopper tabs through the slots to separate the tilt leg from the leg support. 5. Lay the tilt leg and the leg support flat. 6. Press the two tabs locking the legs to the multiline terminal and pull the legs toward you, lifting t...

  • Page 442

    Issue 7.0 univerge sv8100 6 - 46 installing sv8100 optional equipment 8. Push latch to right to unlock the cradle unit. Then push the cradle unit forward to separate from the terminal body. 9. Fit the projections on the side of the psa-l unit into the guide holes on the side of the terminal and pull...

  • Page 443

    Univerge sv8100 issue 7.0 system hardware manual 6 - 47 10. Gently press the serial cable into the grooved cutout for the cable. 11. Connect the serial connection cord (refer to figure 6-39 attach psa-l unit to the multiline terminal on page 6-46 ) from the psa-l unit to the terminal body. 12. Open ...

  • Page 444

    Issue 7.0 univerge sv8100 6 - 48 installing sv8100 optional equipment 14. For the handset, set the connector in place. 15. Attach the analog trunk cable and the handset cable. Refer to figure 6-35 psa-l unit connections on page 6-44 . 16. Reinstall the legs, pushing upwards until both locks snap int...

  • Page 445

    Univerge sv8100 issue 7.0 system hardware manual 6 - 49 21. Pull tab down and lift out the numbered keypad panel. 22. Install the new keypad panel supplied with the psa-l unit. 23. Reinstall both plastic panels to the front of the multiline terminal (refer to figure 6-46 install plastic panels on pa...

  • Page 446

    Issue 7.0 univerge sv8100 6 - 50 installing sv8100 optional equipment 24. Connect the line cord to the adapter. 25. Connect the user system (kts or pbx) cable. 26. If required, remove the side panel from the original cradle unit. 11.5.2 using the psa-l adapter 1. Placing calls: when the pstn line is...

  • Page 447

    Univerge sv8100 issue 7.0 system hardware manual 6 - 51 2. Answering calls: if you receive a call via pstn during a conversation via lan, answer the call by completing the lan call and placing the handset back into the cradle. Change the lan/pstn change switch to pstn and then lift the handset to an...

  • Page 448

    Issue 7.0 univerge sv8100 6 - 52 installing sv8100 optional equipment 11.6.1 installing the gba-l unit 1. Turn multiline terminal upside down. 2. Unplug the line cord and handset cord from the multiline terminal. . Only one gba-l unit can be attached to the dtl/itl multiline terminal. 3. Lower the t...

  • Page 449

    Univerge sv8100 issue 7.0 system hardware manual 6 - 53 4. Push the two stopper tabs through the slots to separate the tilt leg from the leg support. 5. Lay the tilt leg and the leg support flat. 6. Press the two tabs locking the legs to the multiline terminal and pull the legs toward you, lifting t...

  • Page 450

    Issue 7.0 univerge sv8100 6 - 54 installing sv8100 optional equipment 7. Plug in the lan cable and gently press the cable into the grooved cutout (refer to figure 6-50 attach the lan cable ). 8. Plug in the dc power cable and gently press the cable into the grooved cutout (refer to figure 6-51 attac...

  • Page 451

    Univerge sv8100 issue 7.0 system hardware manual 6 - 55 9. Assemble the legs and bracket then align with tab holes (refer to figure 6-52 align bracket with terminal ). 10. Pass the lan and dc power cables through the bracket (refer to figure 6-53 pass cabling through bracket ). Figure 6-52 align bra...

  • Page 452

    Issue 7.0 univerge sv8100 6 - 56 installing sv8100 optional equipment 11. Slide the supporting bracket forward until a click is heard (refer to figure 6-54 secure bracket to terminal ). 12. Secure base of gba-l unit to bracket assembly (refer to figure 6-55 secure gba-l unit base to bracket assembly...

  • Page 453

    Univerge sv8100 issue 7.0 system hardware manual 6 - 57 13. Install the nec provided cat 5 ethernet cable (refer to figure 6-56 ip phone(x) connection ). 14. Install the nec provided cat 5 ethernet cable (refer to figure 6-57 pc(x) connection ). Figure 6-56 ip phone(x) connection figure 6-57 pc(x) c...

  • Page 454

    Issue 7.0 univerge sv8100 6 - 58 installing sv8100 optional equipment 15. Install the nec provided power cable (refer to figure 6-58 dc power connection ). 16. Connect the core then plug in the network connection cable (refer to figure 6-59 lan(=) connection ). Figure 6-58 dc power connection figure...

  • Page 455

    Univerge sv8100 issue 7.0 system hardware manual 6 - 59 17. Install the cable from the optional external ac adapter (refer to figure 6-60 ac to dc in connection ). . The ac adapter (ac-l unit) must be ordered separately. 18. Cable installation for the gba-l unit complete (refer to figure 6-61 gba-l ...

  • Page 456

    Issue 7.0 univerge sv8100 6 - 60 installing sv8100 optional equipment 11.6.2 gba-l unit connection the following chart outlines the connectivity available to the gba-l unit: 11.6.3 led display the following provides a list of each led and associated operation and status indications. Refer to figure ...

  • Page 457

    Univerge sv8100 issue 7.0 system hardware manual 6 - 61 s ection 12 p ower f ailure t elephones 12.1 power failure the system allows connection for basic telephone service during a power failure. The power failure operation occurs during a commercial power failure, and is not affected by blade failu...

  • Page 458

    Issue 7.0 univerge sv8100 6 - 62 installing sv8100 optional equipment 12.2 connector pin-outs on coiu blade for power failure circuits 12.3 installing the power failure telephones 1. Connect an rj-61 connector to the coiu blade installed in the system. 2. Install a modular jack for each single line ...

  • Page 459

    Univerge sv8100 issue 7.0 system hardware manual 6 - 63 figure 6-64 power failure connector (cn3) shown on cd-4cota blade.

  • Page 460

    Issue 7.0 univerge sv8100 6 - 64 installing sv8100 optional equipment.

  • Page 461

    This page is intentionally left blank.

  • Page 462

    Nec reserves the right to change the specifications, functions, or features at any time without notice. Nec has prepared this document for use by its employees and customers. The information contained herein is the property of nec and shall not be reproduced without prior written approval of nec . D...