3.5. FAULT CLEARING
If any fault occurs, the LCD screen will display the Fault Message, Red LED Alarm (Fault) will be
lighted. Remove cause of the fault and the unit will remain in Fault Mode. A short press (0.1 sec-
onds) of the ON/OFF button will clear the Fault Message and the EVO Inverter Charger will return to
operational status (ifthe fault condition no longer exists). Refer to section 7 on “Fault Messages”.
3.6 OPERATING MODES AND DISPLAY SCREENS
There are 4 Operating Modes for the EVO Inverter Charger that will be displayed on the
Remote Screen at any given time (see Fig 3.1): (i) Standby (ii) Inverting (iii) Charging and (iv)
Power Saving. Each mode has several screens of status information such as Voltage/Cur-
rent/Power etc. The majority of Mode screens shown in Fig 3.1 are self explanatory, but the
Charging Mode Status screens require additional details which are shown at Section 3.6.1.
STANDBY
BATTERY 12.000V
POWER SAVING
BATTERY 12.000V
INVERTING
OUTPUT
120.00V
CHARGING
INPUT 1
120.00V
N-CC
Fig 3.1 EVO-RC Mode Screens
3.6.1 Charging Mode Screens Explanations
Please refer to 18 Screens shown against Pages 1 to 18 under Group 3 "CHARGING" at Fig
3.2. The 1
st
line of the Display Screen for Charging Mode shows CHARGING on the left and
abbreviated information format "Charging Mode - Charging Stage" on the right corner. The
following abbreviations have been used:
Abbreviation
(Group 3 Screens)
Normal (N), 3 Stage Charging:
Bulk, Absorption, Float
Equalization (E), 4-Stage Charging:
Bulk, Absorption, Equalization, Float
N-CC
Constant Current (CC), Bulk Stage
–
N-CV
Constant Voltage (CV), Absorption Stage –
E-CC
–
Constant Current (CC), Bulk Stage
E-CVA
–
Constant Voltage Absorption (CVA) Stage
E-CVE
–
Constant Voltage Equalization (CVE) Stage
FLOAT
Float Stage
Float Stage
For example, in Fig 3.2, the 1
st
line of information under Column 4 (Group 3) "Charging"
shows "N-CC" in the right corner. This means that the unit is in Normal (N), 3-Stage Charg-
ing Mode and is in Constant Current (CC) Bulk Stage.
3.6.2 Overall Operating Mode Display Screen Menu Map
Overall Operating Mode Display Screen Menu Map is shown at Fig 3.2. Any screen within the
Menu Map can be identified by 2 co-ordinates: "Group No." (Column) and "Page No." (Row).