Samlexpower Evolution EVO-2212 Owner's Manual - page 99
6 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 7
APPENDIX A
SECTION 3 |
Operation
3.2 POWER ON / POWER OFF
Power ON
Press ON/OFF Key and hold for 2 seconds to turn the EVO Inverter Charger ON.
POWER ON...
SEARCHING ID...
ID= 1
EVO-3012 VERX.XX
INVERTER/CHARGER
ò
ò
When the EVO Inverter Charger is OFF and the ON/OFF key
is pressed and held, the LCD screen shows “POWER ON…”
and the Status LED flashes 3 times. After 2 seconds, EVO-
RC starts to search for the communication ID of the EVO
Inverter Charger it is attached to. The LCD screen shows
“SEARCHING ID” on the first line and shows the ID number
found on the second line. When the default ID of “1” is
found, the display will then show the EVO Inverter Charger
Model No. and Firmware Version (3 digit number X.XX) as
shown on the left.
Power OFF
Press ON/OFF Key and hold for 5 seconds to turn OFF the EVO Inverter Charger.
POWER OFF...
When EVO Inverter Charger is ON and the ON/OFF key is
pressed and held for minimum of 5 seconds, the LCD screen
will show “POWER OFF…” and both the Status and Alarm
LEDs will turn ON. Now release the ON/OFF key (Please note
that Power Off sequence will be completed and display
"POWER OFF..." will disappear only when the ON/OFF key
is released).
NOTE: If the EVO Inverter Charger has AC input voltage
over 60VAC, the Power OFF function is disabled and the
unit will remain in the ON condition if the power off
sequence is attempted. The AC input must be removed
before the unit can be powered OFF.
3.3 DATE AND TIME SETUP
Set date and time as per procedure given at Section 4.9: "GROUP 6 PARAMETER SETUP: TIME
SETTING".
3.4 STANDBY MODE
When in Standby Mode, the EVO will stop inverting or passing through AC input to AC out-
put. Also, charging is cancelled when in Standby Mode.
A short press (0.1 seconds) of the ON/OFF Button will change the operational mode from
Inverting or Charging Mode to Standby Mode. A subsequent short press when in Standby
Mode will return the EVO Inverter Charger to Inverting or Charging Mode.
This mode is used for uploading firmware for EVO Inverter Charger through the SD Card.
This mode may also be used to temporarily halt inverting, charging and AC pass through.