Samlexpower Evolution EVO-2212 Owner's Manual - page 106
14 | SAMLEX AMERICA INC.
APPENDIX A
SECTION 4 |
Parameter Setup
4.2 PARAMETER SETUP PROCEDURE – GENERAL
Please refer to Fig 4.3 below.
The Enter key is used to enter Parameter Setup Mode from any Operating Mode Screen in Fig 3.2.
Example in Fig 4.3 below starts with Inverting Mode Screen (Group 2, Page 1 in Fig 3.2). After the
Enter key is pressed, the Up/Down keys are used to navigate to the different Parameter Groups
(Groups 1 to 7). When the Group for the desired setting is displayed on the LCD, the Enter Key is
used again to select this Group. The Up and Down Keys are used to move to the individual param-
eters within the Group.
Pressing the Back Key will exit the specific Parameter, or Group backing to previous level.
There is a 30 second timeout for setting parameters; after 30 seconds the Setting Mode will
be cancelled and the EVO-RC will revert to the mode associated with current operation.
It is highly recommended to set the EVO Date and Time (Parameter Group 6) as this value is
used to record data logging files. (Refer to Section 4.9 for Date and Time set up).
Group 1
Enter Key
Back Key
Any Operationg Mode
Screen from Fig 3.2
Parameter Setup Screen
(eg. BULK CURRENT)
“Select Group” Menu Map
SELECT GROUP
CHARGE CURVE
BULK CURRENT
40 A
INVERTING
OUTPUT
120.00V
SELECT GROUP
STOP SD CARD
Group 2
SELECT GROUP
INPUT SETTING
Group 3
SELECT GROUP
INPUT LOW LIMIT
Group 4
SELECT GROUP
INPUT HIGH LIMIT
Group 5
SELECT GROUP
OTHER FUNCTION
Group 6
Group 7
SELECT GROUP
TIME SETTING
ò
ò
ò
ò
ò
ò
ò
ò
ò
ò
ò
ò
ò
ò
Group up (Up Key)*
Group down (Down Key)**
òò
ò
ò
ò
ò
***
Fig 4.3 "Select Group" Menu Map and Example for Setting Bulk Current
NOTES:
*
Group Up is shown with downward pointer because Group Nos. in this Menu Map
increase in the downward direction
** Group Down is shown with upward pointer because Group Nos. in this Menu Map
decrease in the upward direction
*** Group 7 screen will be shown only when SD card is inserted.