Tally T6090 Maintenace Manual - page 24
T6090 Maintenance Manual
1–8
Acoustics
The noise generated by the T6090 printer varies according to its configuration as shown in the
table that follows:
Table 1–7. Acoustics
Printer
Sound Power per
Sound Pressure Level
Configuration
ISO 7779-C
(9 position average)
Tabletop Unit
7.4 bels
57 dBA
Printer with Pedestal
6.9 bels
52 dBA
Quick Access Configuration
7.9 bels
62 dBA
Power Supply
The printer requires single phase, 47 to 63 Hz. 90 to 264 VAC input power. The printer’s
universal power supply automatically adjusts to the correct values. A fuse is provided to
interrupt power to the power supply. The following table gives typical current values.
Table 1–8. Power Requirements
External Power
Current/Wattage Requirements
Supply
@ Nominal Voltage
AC Volts
Frequency
Average
Peak
Average
Average
(RMS)
(Hz)
Operating
Operating
Idle (<5 min.)
Idle (>5 min.)
110
50
2.56 A/166 W
6.30 A/506 W
0.88 A/41 W
0.64 A/25 W
110
60
2.57 A/171 W
6.29 A/508 W
0.85 A/42 W
0.62 A/25 W
220
50
1.39 A/168 W
3.91 A/496 W
0.41 A/42 W
0.31 A/26 W
Cooling System
Cooling system malfunctions are detected and a failure will result in shuttle motion, paper
motion, and printing functions being inhibited. The malfunction will be reported on the
control panel display.
Safety
Personnel hazard areas have restricted access with appropriate warning labels. Catastrophic
equipment failures are inhibited with protective functions in major areas of overload potential.