Tally T6090 Maintenace Manual - page 98
T6090 Maintenance Manual
4–28
Reinstalling
STEP 1.
Reconnect the Platen Open Sensor to the Platen.
It is possible that the end assemblies of the platen may come off of the platen when you
remove it. When you reassemble the platen make sure ALL parts are included. Some
parts are small (for example, the spring washers on the right end of the platen) and are
easily lost. Refer to the figure below to identify the parts and the installation sequence.
Platen
Platen Open
Sensor
Form
Thickness
Lever
Platen
Adjust
Plate
Curved Spring
Washers
Platen Adjust Plate
Platen - Right End
Platen - Left End
Figure 4–25. Platen End Assemblies
STEP 2.
Place the springs back on the ends of the platen and secure it in place.
STEP 3.
Reinstall the Hammer Bank.
Before you reinstall the Ribbon Platform, check the hammer to platen gap and adjust as
necessary (see Procedure 25).
After completing the installation, perform a Hammer Calibration to maintain optimum print
quality (see PrntCal Parameter in Chapter 2).