Tally T6090 Maintenace Manual - page 51
Chapter 3: Troubleshooting
3–5
Table 3–1, Continued
MESSAGE
Explanation and Corrective Action
Offline Dump On
Explanation:
The printer is in Offline condition and Dump Mode is enabled.
Corrective Action:
No corrective action is necessary. Place the printer back Online when
you are ready to print. (See the explanation at the beginning of this
chapter and in Chapter 2, under Hex Dumps for explanations about
how the data from the host is printed.)
Online Dump On
Explanation:
The printer is ready to accept and print data from the host through
Dump Mode. (See the explanation at the beginning of this chapter
and in Chapter 2, under Hex Dumps for explanations about how the
data from the host is printed.)
Corrective Action:
No corrective action is required.
Overflow VFU
Explanation:
An excessive number of bytes has been sent by the host in a VFU
download.
Corrective Action:
Correct data and retransmit from host.
Panel Fault
Explanation:
The control processor has detected a fault in the circuitry for the
control panel. Depending on the location of the fault, this message
may not display.
Corrective Action:
Remove and replace the Control Panel. If this does not clear the fault,
remove and replace the Engine Controller CBA.
Paper Motion Flt
Explanation:
The control processor has detected that the paper has failed to move
the required distance after sending a command to the Paper Drive
Motor.
Corrective Action:
Check for paper feed problems. If there are any paper feed problems,
correct them, then depress the CLEAR key to clear the fault and
continue operation.
If this does not clear the problem, check for paper debris blocking the
sensor.
If problem still exists, check cable connection at the Engine CBA. If it
fails again, check the sensor’s voltage output (in the meter parameter
of the Control Panel). The reading should be approx. +5.0 Volts
without paper and
≤
+ 3.0 Volts with paper. Ideally the voltage reading
should differ at least 2V between paper in and paper out. If the
differential is less than 2V, or the voltage does not change or is zero,
the Upper Tractor set (Includes Paper Motion Sensor) needs to be
replaced.
If all the above does not clear the problem, remove and replace the
Engine Controller CBA.