Max T (Maximum Temperature) Parameter (Menu Level 2)
Max T is the thermal limit for the printer. If the thermistor on the Engine Controller PCB
exceeds this limit, the Thermal Fault message will appear on the Control Panel Display.
DO NOT change the factory setting.
EnStar (Energy Star) Parameter (Menu Level 2)
This parameter allows you to control Energy Star Operation on the printer.
Energy Star selections (Menu Level 3)
OFF
ON
Clear Parameter (Menu Level 2)
This parameter provides you with a means of clearing part or all of NVRAM.
Clear selections (Menu Level 3)
CalData
Clears the calibration data from NVRAM. When CalData is selected you will
have to perform a Hammer Calibration Routine before using the printer.
Counts
Clears the count information from NVRAM.
NVRAM
Clears ALL NVRAM.
Fault Override (FltOvrd) Category (Menu Level 1)
This category provides you a means of controlling fault reporting from the Engine Manager to
the Control Processor. Each of the following parameters has two selections: OFF and ON.
When the parameter is set to OFF, faults are reported as they happen (Fault Override is dis-
abled). When the parameter is set to ON, faults are not reported on the display (Fault Override
is Enabled).
Pap Mot (Paper Motion) Parameter (Menu Level 2)
This parameter provides fault override for Paper Motion Faults.
Pap Out (Paper Out) Parameter (Menu Level 2)
This parameter provides fault override for Paper Out Faults.
Rib Mot (Ribbon Motion) Parameter (Menu Level 2)
This parameter provides fault override for Ribbon Motion Faults.
Shuttle Parameter (Menu Level 2)
This parameter provides fault override for Shuttle Fault reporting.
Temp (Temperature) Parameter (Menu Level 2)
The Temp Parameter provides fault override for Temperature Threshold fault reporting.