4RF Aprisa SR+ User Manual - page 122
Managing the Radio | 119
Aprisa SR User Manual
SOFTWARE MANUAL LOCK
The software Manual Lock is a software implementation of the Hardware Manual Lock switch on the
Protection Switch. The Software Manual Lock is intended to be used when making changes to the
Protected Station remotely via SuperVisor, to prevent the Protected Station from switching as a result of
the changes being made. See ‘Setting the Software Manual Lock’ on page 33 for a recommended process
to follow to make remote configuration changes.
Lock Active To
This parameter sets the Protection Switch Software Manual Lock. The Software Manual Lock only operates
if the Hardware Manual Lock is deactivated (set to the Auto position).
Option
Function
Automatic
The protection is automatic and switching will be governed by
normal switching and blocking criteria.
Primary
The primary radio will become active i.e. traffic will be switched
to the primary radio.
Secondary
The secondary radio will become active i.e. traffic will be switched
to the secondary radio.
Warning: If the Software Manual Lock is set to Primary or Secondary, the Software Manual Lock must be
set to the same value on both Protected Station radios. If the Software Manual Lock is set to primary on
one radio, and secondary on the other radio, management communication to the radios may be lost if
both radios become set to 'standby' mode.