4RF Aprisa SR+ User Manual - page 133
130 | Managing the Radio
Aprisa SR User Manual
Parameters
Parameters > Summary
The Parameters Summary screen is a dynamic page that will display the parameters associated with the
active alarms, set on ‘Events > Events Setup’ on page 126. This screen is an example only showing some
monitored parameters with active alarms.
The following is a list of alarm events that are monitored:
Monitored Parameter
Unit
Scale Factor
Event ID
Event Display Text
Current Temperature
Celsius
10
4
Temperature Threshold
Last RX Packet RSSI
dBm
10
7
RSSI Threshold
Last Sample RX CRC Error
Ratio
100
9
RX CRC Errors
Last Sample RF RX Data
Count
1
34
RF No Receive Data
Last Sample Eth1 RX Data
Count
1
10
Port 1 Eth No Receive Data
Customer Eth1 Data RX Errors
Ratio
100
11
Port 1 Eth Receive Errors
Customer Eth1 Data TX Errors
Ratio
100
12
Port 1 Eth Transmit Errors
Last Sample Eth2 RX Data
Count
1
35
Port 2 Eth No Receive Data
Customer Eth2 Data RX Errors
Ratio
100
36
Port 2 Eth Receive Errors
Customer Eth2 Data TX Errors
Ratio
100
37
Port 2 Eth Transmit Errors
Last Sample Serial RX Data
Count
1
13
Serial Data No Receive Data
Customer Serial Data RX Errors
Ratio
100
14
Serial Data Receive Errors
Last TX Packet PA Current
mA
1
None
Last TX Packet AGC
mV
1
None
Last TX Packet Reverse Power
dB
10
None
Current RSSI
dBm
10
None
If an associated alarm event occurs, the Parameters table will display the current value for that