Chapter 3
3-32
3.1.16.11
Removing the Plate
0006-3035
1) Remove the connector [1] of the DCNT board.
2) Remove the three screws [2] and then removes the
plate [3].
F-3-135
3.1.16.12
Removing the Power
Supply Shield Plate
0003-7521
1) Remove the five screws [1] to remove the power
supply shield plate [2].
F-3-136
3.1.16.13
Removing the Power
Supply Assembly
0006-3037
1) Remove the three screws [1]. (The external cover is
omitted from the illustration below to show the
instructions clearly.)
2) Remove the four connectors [2] as well as the flat
cable [3] on the DCNT board.
F-3-137
3) As you remove the bosses on both sides [1], lower
the front part of the power supply assembly [2].
Then pull it to remove the power supply assembly.
F-3-138
3.1.16.14
Removing the Top
Sensor
0006-3038
1) Place the main unit down on its front face (so that
the interior of the main unit is easily visible).
2) Remove the connector [1] on the DCNT board and
take the cable off the cable guide.
3) Remove the screw [2] and remove the top sensor
[3].
F-3-139
[1]
[2]
[3]
[1]
[2]
[1]
[2]
[2]
[1]
[3]
[1]
[2]
[1]
[2]
[3]