D-Link DXS-1100 series User Manual - page 54
D-Link 10 Gigabit Ethernet Switch User Manual
4
4
7
7
Bucket Number: Enter Specifies the number of buckets specified for the RMON collection history group of
statistics. The range is from 1 to 65535. The default value is 50.
Interval: Enter the time in seconds in each polling cycle. The range is from 1 to 3600.
Owner: Enter the owner string. The string can be up to 127 characters.
Click Add to add a new entry based on the information entered.
Click Delete to remove the specified entry.
Click Show Detail to see the detail information of the specific port.
Enter a page number and click Go to navigate to a specific page when multiple pages exist.
After clicking Show Detail, the following window will appear.
Figure 4.58 – Management > RMON > RMON History Table
Click Back to return to the previous window.
Management > RMON > RMON Alarm Settings
This window is used to configure and display alarm entries to monitor an interface.
Figure 4.59 – Management > RMON > RMON Alarm Settings
The fields that can be configured are described below:
Index: Enter the alarm index. The range is from 1 to 65535.
Interval: Enter the interval in seconds for the sampling of the variable and checking against the threshold.
The valid range is from 1 to 2147483647 seconds.
Variable: Enter the object identifier of the variable to be sampled.
Type: Select the monitoring type. Options to choose from are Absolute and Delta.
Rising Threshold: Enter the rising threshold value between 0 and 2147483647.
Falling Threshold: Enter the falling threshold value between 0 and 2147483647.
Rising Event Number: Enter the index of the event entry that is used to notify the rising threshold crossing
event. The valid range is from 1 to 65535. If not specified, no action is taken while crossing the ringing
threshold.
Falling Event Number: Enter the index of the event entry that is used to notify the falling threshold crossing
event. The valid range is from 1 to 65535. If not specified, no action is taken while crossing the falling
threshold.
Owner: Enter the owner string up to 127 characters.