System configuration guide sv8100 ( r3 ) nov 2009 necic-ap-010 issue 3.02.
Revision table issue date description approved by prepared by 1.0 2008/9/22 1 st release h.Yamashita t.Tagawa 1.2 2008/10/29 add asia version h.Yamashita t.Tagawa 2.0 2009/2/5 add 9.5 inch gw to us/au h.Yamashita h.Yamashita 3.0 2009/10/16 add 9.5 inch b/e to us h.Yamashita h.Yamashita 3.01 2009/11/...
3 table of contents 1. General information ......................................................................................................4 2. Equipment list ..............................................................................................................8 3. System block diagram...
1. General information the sv8100 is a full-featured ip based communications system providing a rich feature set of existing system, with pure voice over ip (voip) communications, across corporate local and wide area networks (lan and wan). Dt700 series telephones are designed to provide a converged...
(via tcp/ip) sp310 softphone fig 1 simplified view of sv8100 system connectivity 5.
Highlights of the sv8100/sv8300 are as follows: pure ip system capable tdm configuration the sv8100 supports both pure ip switching (peer-to-peer connections) and time division switching. The pure ip switching is provided for communications between dt700 series telephones and for ccis connections wi...
Easy installation (front cabling and enhanced o&m tool) cable connectors (rj-45 or rj-61) are located on the front panel of each ksu and board. It increases efficiency of the cabling work. Also, pcpro provides enhanced user interface. Quick setup tool provides easy setup (system data programming) fo...
2. Equipment list the following table lists all equipment for the sv8100 system. Table 2 equipment list category item name item description note chs2u-us 19-inch ksu (6-slot) for us/lasc chs2u-au 19-inch ksu (6-slot) for au chs2u-eu 19-inch ksu (6-slot) for eu/ot/hk eu, ot and hk common chassis. 19 ...
Category item name item description note pz-me50-ot memory expansion board for cd-cp00-ot/china/hk(r1)/lasc. Pz-me50-hk memory expansion board for cd-cp00-hk (r2) pz-32ipla 32 ch voip for cd-cp00-xx pz-64ipla 64 ch voip for cd-cp00-xx pz-128ipla 128 ch voip for cd-cp00-xx cd-4cota 4 loop start inter...
Category item name item description note pgd(2)-u13 adp doorphone/paging i/f adapter for au dp-d-1a doorphone chsgw small batt box internal battery box for 9.5-inch ksu. Chsgw small batt set short term battery set for chsgw small batt box. 2 x 0.8ah-12v locally provided chs2u batt mtg kit internal b...
3. System block diagram sv8100 system block diagram shows the boards that can be installed in the ksu and the number of channels supported when the board is installed. List of abbreviations lists abbreviations used in the diagram. Table 3 list of abbreviations abbreviation description acd automatic ...
Abbreviation description pbr pb receiver (on cpu) pbsnd pb sender (on cpu) pcpro pc programming pft power failure transfer plo phase locked oscillator (on cpu) pms property management system pri primary rate interface prt primary rate interface board ps personal station psa pstn adapter (analog) pva...
Fig 3 sv8100 system block diagram 13.
4. Maximum system capacities the chs2u-xx is a compact 19” ksu that has six universal slots and one power supply unit. When the cd-cp00-xx is installed in the first chs2u-xx, it is referred to as the controlling ksu. Additional ksu, referred to as expansion ksu, can be installed to increase the capa...
4.1 system configuration the sv8100 19” ksu provides 104 (u-law) /111 (a-law) timeslots (80 digital terminals) and can be expanded, using three additional 19” ksu, for a maximum of 416 (u-law) /444 (a-law) timeslots (368 digital terminals). Through ip connection and four additional 19” ksu, the syst...
4.2 maximum system capacities - boards the system’s universal architecture gives you great flexibility when installing package boards. You can install a package board in any slot, provided you follow the guidelines in the chart below. Table 4-2-1 common control boards 9.5” b+e 9.5” b+e 9.5” b+e x 4 ...
Table 4-2-2 station boards 9.5” b+e 9.5” b+e 9.5” b+e x 4 hardware 9.5” gw 19” ksu 19” ksu 19” ksu x 4 network ed ksus number of slot(s) for interface package 2 slots w/ cpu 5 slots w/ cpu 6 slots w/o cpu 23 slots 240 slots comments cd-8dlca (8 digital station interface) 2 5 6 23 32 pz-8dlcb (8 digi...
Table 4-2-3 trunk boards 9.5” b+e 9.5” b+e 9.5” b+e x 4 hardware 9.5” gw 19” ksu 19” ksu 19” ksu x 4 network ed ksus number of slot(s) for interface package 2 slots w/ cpu 5 slots w/ cpu 6 slots w/o cpu 23 slots 240 slots comments cd-4cota/4cotb/4cotc (4 analog trunk) 2 5 6 23 25 pz-4cote/4cotf/4cot...
Table 4-2-4 optional boards 9.5” b+e 9.5” b+e 9.5” b+e x 4 hardware 9.5” gw 19” ksu 19” ksu 19” ksu x 4 network ed ksus number of slot(s) for interface package 2 slots w/ cpu 5 slots w/ cpu 6 slots w/o cpu 23 slots 240 slots comments cd-pvaa (conference bridge) 2 5 6 23 32 cd-etia (switching hub wit...
5. Power-based calculator chart the sv8100 system uses two types of power factors. For a single ksu chart refer to table 1 board power factor. For the maximum number of specific boards per package, see table 2 maximum number of package installed. Refer to table 3 terminal power factor below, for the...
6. Power requirement 6.1 power supply specification a dedicated 120vac 60 hz circuit located within seven feet of the chassis is required. A separate dedicated outlet for each chassis should be installed. Table 6-1 power supply specification us au eu/ot power requirements 120 vac @ 15a controlling/b...
6.2 power supply consumption below table shows system power consumption of each configuration. Table 6-2 power consumption chassis country maximum rms current watts used (idle) watts used (maximum) us 2.19a au 1.15a basic chassis – cd-cp00-xx chassis eu/ot 1.15a 96w 130w us 4.38a au 2.3a basic chass...
7. Chs2u-xx 19-inch ksu the chs2u-xx ksu has six universal board slots for legacy line / trunk board (single line telephone interface, digital multi-line terminal interface, central office trunk, isdn pri interface, etc.), in-skin application boards (in-skin ums, in-skin router, etc.). It also house...
7.1 floor mounting the 19” ksu the chs2u-xx controlling and expansion ksu can be mounted on the floor using the chs base unit and the chs2u joint bracket kit. Fig7-1 chs2u floor mounting table 7-1 hardware for floor mounting installation description b code feature chs base unit be106406 floor mount ...
7.2 stand mounting the 19” ksu a single or multiple ksu can be stand mounted. Controlling ksu can be stand mounted using the chs2u stand kit (k) and expansion ksu can be stand mounted together using chs2u stand kit (ext). Upto total 3 ksus can be stand mounted. Fig7-2-1 stand mounting of controlling...
7.3 wall mounting the 19” ksu when wall mounting controlling ksu, ensure the wall can support the weight of the ksu (25kg per system ksu ---- including boards, cords, power supply, etc.). The ksu is secured to the wall with a wall mount bracket. Nec recommends only one ksu per wall mount. Fig 7-3 ta...
7.4 rack mounting the 19” ksu a single or multiple ksu can be mounted in the iec-standard 19 inch rack . Controlling and expansion ksu can be racked mounted by stacking them horizontally. The 19” ksu requires two rack mount brackets per ksu for mounting. Fig 7-4-1 chs2u rack mount brackets (2 pcs/ki...
8. Chs2u-gw-xx / chs2u b- xx / chs2u e (9.5 inch ksu) the chs2u-gw-xx / chs2u-b-xx , 9.5 inch chassis has three (slot 1 for cpu) universal board slots for legacy line / trunk board (single line telephone interface, digital multi-line terminal interface, central office trunk, isdn pri interface, etc....
8.1 wall mounting the 9.5 inch ksu when wall mounting the ksu, ensure the wall can support the weight of the ksu (25 lbs per system ksu ---- including boards, cords, power supply, etc.). The ksu is secured to the wall with a supplied wall mount bracket. Fig 8-1-1 wall mounting for 9.5 inch ksu fig 8...
8.2 stand mounting the 9.5 inch ksu chs2u-gw-xx / chs2u-b-xx, 9.5 inch ksu can be stand mounted using the bracket supplied for wall mount. This bracket is not for use with a combined base (chs2u b-xx) and expansion (chs2u e) chassis. A combined base and expansion chassis should only be rack or wall ...
8.3 rack mounting the 9.5 inch base and expansion chassis to rack mount the combined base (chs2u b-xx) and expansion (chs2u e) chassis, the ip3-rack mount bar set is required. Base and expansion chassis must be installed vertically for proper air circulation. 1) attach the metal rack mount brackets ...
2) secure the (chs2u b-xx) and (chs2u e) chassis to the horizontal bars using two screws at each point. Fig 8-3-2 attach (chs2u b-xx) and (chs2u e) chassis to rack table 8-3 hardware for 9.5 inch b+e rack mounting installation description b code feature ip3d-rack mount bar set be107556 rack mount br...
9. Battery type below table shows each battery box, cable, and battery type with supplier product name. Two batteries are used as one set. The same manufacturer should be used for the set. Table 9 battery box configuration battery box type battery box cable set battery supplier product name terminal...
9.1 internal battery mounting kit (19 inch ksu) an internal battery source using two batteries can be installed using the chs2u batt mtg kit (mounting kit) and chs2u batt cable int (internal cabling). Chs2u batt mtg kit (backup time = 10 minutes/24 terminals) fig 9-1-1 installing battery cable fig 9...
9.2 attaching chsgw small batt box (9.5 inch ksu) an optional chsgw small batt box can be installed to provide external battery power to the 9.5 inch ksu during power failure. This chsgw small batt box can power the system approximately 10 minutes. Fig 9-2 attaching chsgw small batt box to 9.5 inch ...
9.3 long term battery box when chs large batt box can be used both for 19 inch ksu and 9.5 inch ksu, there are two types of the external battery cable. Connections are shown below. The battery cables between chs2u chassis and chs batt box are attached in the chs large batt box. Only floor mounting i...
Fig 9-3-2 inside view of external battery box 37.
10. Voip daughter board (voipdb) there are 3 types of voipdbs, pz-32ipla, pz-64ipla and pz-128ipla. To select either pz-32ipla, pz-64ipla or pz-128ipla, a detailed traffic calculation is necessary. The following table shows the voipdb channels required in each voip connection. Table 10 voipdb channe...
11. Vm configuration following table shows vm/vrs feature configuration using pz-vm21, cd-vm00 and suitable application cf. Table 11 vm configuration country type cf product name language(default) cf size max port function base config in mail aks inmail au az english japanese chinese(mandarin) 512mb...
12. License when installing the system and activating operational features beyond default system ports/features available initially, several licenses are required. The following table shows license models available in sv8100. “ ✓ ” means these license are applied. “on ” means these functions are alw...
Category functions min max license model us bssd au eu ot vrs channel 1 16 (*2) lks-vm-vrsxx-lic ✓ ✓ on on vm channel 1 16 (*2) lks-vm-inmailxx-lic ✓ ✓ on on vrs/vm multi-language 1 20 lks-vm-language -lic ✓ ✓ ✓ ✓ vm box users 1 512 lks-vm-user1-lic on on ✓ on inmail email notification on/off lk-vm-...
Category functions min max license model us bssd au eu ot assistant upgrade (softphone to assistant) 1 128 lk-desktop suite- pc assistantxx-lic ✓ ✓ r2 ✓ ✓ softphone client 1 128 lks-sp e client-ip xx-lic ✓ r2.5 ✓ f ✓ f ✓ f desktop client 1 128 lk-dt client xx-lic ✓ r2.5 ✓ f ✓ f ✓ f desktop client wi...
Category functions min max license model us bssd au eu ot (*1) eu version of main s/w have 128 ports capability at default, if pz-me50-eu is installed full 128 ports will be available, if not installed port size will be limited to 64 ports. Lk-sys-256 port-lic license will increase the system capaci...
44 14. Dsp resources cd-cp00-xx have 128 channel dsp sender both for basic and expand chassis, and 32 channel dsp resources (receivers) only for basic chassis. Pz-bs10 have 64 dsp resources (receivers) only for expand chassis. These dsp sender and resources channels are used for following purpose ex...