Tadiran Telecom EMERALD ICE Installation Manual - Power Consumption Table
Emerald ICE Installation & Hardware Reference Manual
2-33
System
Design
2
Example:
Full Load system configuration with 22 EKT phone sets and 8 SLT phone sets the
power consumption at the AC line is 15(KSU3)+3.2(4SLTx2, 6CO, 12EKT) +
4(EKTx22)+12(SLTx8) = 74.2W (max).
2.20
Power Consumption Table
Condition
Cabinet(s)
Max (Watts)
Min (Watts)
KSU 1
(610+2/B &
CCB)
150
10
Required AC power
KSU 2
(BASE/B
Only)
150
5
Power consumption per
EKT phone set
KSU 1 & 2
+2 @ Hands‐free
+1.5 @ Idle
+1.5 @ Off‐hook
0 @ On‐hook
Power consumption per
SLT phone set
KSU 1 & 2
+0.9 @ Ringing
‐
+1.5 (610+2/B)
‐
KSU 1
+3 (CC/B)
Power consumption of
board
KSU 1 & 2
+0.8
(4SLT/B, 6CO/B
12EKT)
‐
Power consumption of
Voice mail card (Flash
version)
KSU 1
+2
‐
Power consumption of
Voice mail card (HD
version)
KSU 1
+6
‐