Yamaha SXV70SJ Supplementary Service Manual - Insp
2-12
INSP
ADJ
3
•
Remove the coolant filler cap and bleed the
cooling system again, as described above.
No air bubbles
→
OK.
•
Add coolant to the specified level.
•
Pour coolant into the coolant reservoir
3
until
the coolant level reaches the “FULL” level mark.
3. Install:
•
Bleed bolt cap (MM700)
•
Seat (VX700/VX700DX/SX700/VT700)
CARBURETOR SYNCHRONIZATION
1. Remove:
•
Carburetors
Refer to “CARBURETORS” in CHAPTER 7.
2. Adjust:
•
Carburetor synchronization
Adjustment steps:
•
Turn the throttle stop screw
1
of carburetor #2
until the specified throttle valve height
a
is ob-
tained.
Throttle valve height
a
:
1.2 mm (0.047 in)
•
Adjust the throttle valve height
a
on carburetor
#1
2
and #3
3
with the adjusting screws
4
.
•
Move the throttle lever 2 ~ 3 times.
•
Make sure that all of the carburetor throttle valves
are at the same height.
3. Install:
•
Carburetors
Refer to “CARBURETORS” in CHAPTER 7.
COOLING SYSTEM/
CARBURETOR SYNCHRONIZATION
SCH2280
SCH2290
SCH2270