Yamaha SXV70SJ Supplementary Service Manual - Elec
8-10
–
+
ELEC
4
3
2
1
R
L
Br
Br/W
IGNITION SYSTEM
SCH8350
SCH8340
LOAD CONTROL RELAY
1. Inspect:
•
Load control relay (black)
1
Inspection steps:
•
Disconnect the load control relay from the cou-
pler.
•
Connect the pocket tester (
Ω
×
1) and battery
(12 V) to the load control relay terminals as
shown.
Positive battery terminal
→
Brown
1
Negative battery terminal
→
Brown/White
2
Positive tester probe
→
Red
3
Negative tester probe
→
Blue
4
•
If load control relay does not have continuity
between the red and blue terminals, replace it.
EMERGENCY ENGINE STARTING
(VX700/SX700/MM700)
If a short circuit occurred in the lighting system, the
signal system, or the meter system, the engine can
be started in an emergency by cutting off the load
control relay.
1. Disconnect:
•
Load control relay (black)
1
2. Start the engine.
SCH8360