3xLogic VX-2A-B-IWD (R) User Manual - page 82
VIGIL Software v8.8 User Manual | VISIX V-Series All-in-One Cameras
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
82
TCP SERVER
Steps:
1). Opening the Setup Tab>Event Configurationdrop-down menu and clicking the TCP Serverlink
will open the TCP Serversettings page.
Figure 7-43: Setup Tab – Event Configuration Menu - TCP Server Settings
2). From the TCP Server setting pages, a user may enter a Portvalue for the TCP Event Server.
Click the Message Customizationbutton to deploy the event message settings for TCP Event
servers.
TCP Message Settings
Description
Message Header Tab
Enable and customize a custom message header.
VCA Tab
Select a default message or configure a custom message for VCA Config,
VCA Alarm and VCA Counter events.
MD Tab
Select a default message or custom message for motion detection events.
Network Tab
Select a default message or configure a custom message for Network
events.
DI/DO Tab
Select a default message or configure a custom message for DI/DOevents.
3). ClickApply to save changes to the TCP Server settings.