Display
Operating Procedure
Description
When the espresso machine is turned off, press and hold
the Encoder Knob.
After about 10 seconds the following
screen is displayed.
Releasing the Encoder Knob the following display appears.
Press the Encoder Knob until the following display appears.
Rotate the Encoder Knob to set the desired value, press the Encoder Knob to confirm the value. Continue with the
programming of the other parameters.
To exit the programming mode, scroll the menu, using the the Encoder Knob.
• To properly calibrate the temperature of any
espresso machine it is import to measure
the temperature of the water exiting the
group by means of an external temperature
measuring device. The difference of the
display temperature and the measured
temperature may be compensated by use
of the “Coffee T. Offset” parameter.
• The OFFSET parameter is used to calibrate
the coffee boiler temperature system to
ensure the display temperature accurately
represents the temperature of the water
exiting the group head.
• This parameter is preset at the factory based
upon initial tests of this espresso machine.
• It is not recommended that this number is
changed.
• Changes to this parameter can cause
unexpected results.
• It is important to write down this value
before making changes to be sure you
can return to the factory programming if
unexpected results occur. Each machine
may have a different value as it is set
individually.
“Technical” Programming
OFF 00:00
Technical
OFF 00:00
Coffee Boiler
1
2
4
Offs. T.Boiler 1
-3.0
Offs. T.Boiler 1
-3.0
3
Language
ENGLISH
5