Maestro e200 series User Manual - page 205
MAESTRO WIRELESS SOLUTIONS
| SERVICES
E200 SERIES | USER MANUAL VERSION 1.0
http://support.maestro-wireless.com
205
12.6
Events
Services > Events
E200 Router is equipped with two digital inputs/outputs (I/O). Digital inputs range
is 3V to 24V and the same input pins are also available to be used as open
collector digital output with maximum 200mA @ 24V. Event page allows you to
mapping actions to events respective to digital I/O’s.
Screen 12.6-1: Event Service Configuration
Parameters
Description
EVENT
Enable
Click to enable the events
Event
Select the event from the available options
DIO_H -
DIO_L
NA
Action
Select the action from options.
SMS – to send the event details using the SMS.
Reboot – To reboot the router.
Mobile Number
Enter the mobile number. The mobile number format must
be:
Text
Enter the text message that will be sent to the configured
mobile number in case of event occurs.
Table 12.6-1: Event Service Configuration