Configuring the External Alarm Outputs
To configure the External Alarm Outputs:
Select Link or Local or Remote > Alarms > Ext Alarm Outputs
Note: When the MHSB mode is enabled on the terminal, the external alarm output 4 is used for protection
switch control so is not available for user alarms.
1. Select the Mapping required for each alarm output.
Mapping
External Alarm Output Function
None
No external alarm output.
Default
Local Major
The external alarm is present when the local terminal has a
major alarm.
Local Minor
The external alarm is present when the local terminal has a
minor alarm.
Remote Major
The external alarm is present when the remote terminal has a
major alarm.
Remote Minor
The external alarm is present when the remote terminal has a
minor alarm.
Remote Input 1
The external alarm is present when the remote terminal
external alarm input 1 is present.
Remote Input 2
The external alarm is present when the remote terminal
external alarm input 2 is present.
Test Major
External alarm test function – major alarm
This setting will output an alarm on the selected output but it
will not show in the alarm table or on the OK LED of the radio
(it is not a 'real' alarm).
This alarm test will clear if radio reboots.
Test Minor
External alarm test function – minor alarm
This setting will output an alarm on the selected output but it
will not show in the alarm table or on the OK LED of the radio
(it is not a 'real' alarm).
This alarm test will clear if radio reboots.