18.1 Error Code Table
18.1.1 Error code tables
This unit has a function for diagnosing its own statuses (especially the sensor outputs). A diagnosis is performed
when appropriate, and if a status is judged to be abnormal, an error code indicating the nature of the trouble is
displayed on the control area.
In the tables below, these error codes are listed, and their detection methods, main causes and remedial action
procedures are described.
The all-numeral 4-digit codes provide details of the errors, and these details can be checked using COPIER >
DISPLAY > ERR in the service mode.
T-18-1
Code
Designation / general description of error
E000
Insufficient temperature rise of fixing unit when power is turned ON
E001
Abnormally high temperature rise of fixing unit (circuit trouble)
E002
Insufficient temperature rise of fixing unit
E003
Fixing unit low temperature trouble
E004
Fixing unit protection circuit trouble
E007
Fixing belt or pressure belt deviation trouble
E008
Fixing unit end-of-life detection error
E009
Pressure belt pressure release error
E012
Drum ITB motor trouble
E014
Fixing motor error
E020
Drum/developer-related trouble
E032
NE controller counter operation failure
E110
Laser scanner motor running trouble
E193
Gate array error
E202
1st mirror stand HP detection trouble
E225
Exposure lamp lighting trouble
E227
Reader unit power supply error
E240
Error in communication between main controller and DC controller
E248
Defective EEPROM on reader controller PCB
E315
Image data trouble
E351
Main controller PCB error
E400
Feeder communication error
E402
Transport motor error
E413
Pressure motor trouble
E490
Wrong model error
E500
Finisher communication error
E503
Saddle communication error
E505
Finisher backup memory error
E514
Bundling (forward rotation direction) error
E520
Offset error
E530
Alignment error