Chapter 18
18-7
0001 Fixing unit end-of-life detection
error
Occurs when the fixing unit end-of-life is detected or when the belt push-
off temporary escape mode was executed but normal operation was not
restored.
E009
Pressure belt pressure release error
0500 Pressure belt unit pressure release
HP search error
Replace the fixing pressure release HP sensor. Replace the fixing pressure
motor. Replace the DC controller PCB 2 (MAISY).
0501 Pressure belt unit pressure release
timeout error
Replace the fixing pressure release HP sensor. Replace the fixing pressure
motor. Replace the DC controller PCB 2 (MAISY).
0502 Pressure belt unit pressure timeout
error
Replace the fixing pressure release HP sensor. Replace the fixing pressure
motor. Replace the DC controller PCB 2 (MAISY).
E012
Drum ITB motor trouble
0001 Drum ITB motor fails to run.
Replace the drumITB moter.
Replace the DC controller PCB 2 (MAISY).
Replace the DCDC converterÅi38VÅj.
0002 Drum ITB motor runs but then
stops running.
0003 When the drum ITB motor fails to
stop
E014
Fixing motor error
0001 Drum Unit / Faulty Connection of
the Toner Receptacle
Replace the drumITB moter. Replace the fixing moter.Replace the DCDC
converterÅi38VÅj. Replace the fixing belt unit.
0002 When the lock was disengaged after
the motor was locked
E020
Drum/developer-related trouble
Concerning the first two digits of the details code in xx12 to xxD0
Å@xx=01: Y
Å@xx=02: M
Å@xx=03: C
Å@xx=04: Bk
xx20 ATR sensor trouble or a broken/
disconnected wire. The drum unit
is not installed properly or there is
trouble in the unit.
Replace the drum unit (check its connections).
xx24 SALT sensor trouble or a broken/
disconnected wire. There is trouble
in the drum unit.
Replace the SALT sensor (clean it). Check the drum unit connections.
Replace the drum unit.
xx25 SALT sensor trouble or a broken/
disconnected wire. There is trouble
in the drum unit. Deterioration in
ITB.
Replace the SALT sensor (clean the sensor window). Replace the drum unit
(check its connections). Replace the ITB (clean it).
xx30 ATR sensor trouble or a broken/
disconnected wire. Incorrect
setting of ATR sensor operation
values. The drum unit is not
installed properly or there is trouble
in the unit.
Replace the drum unit (check its connections).
xx34 Sample images drawn by ATR
control are not created. SALT
sensor trouble or a broken/
disconnected wire. There is trouble
in the drum unit. Deterioration in
ITB.
Replace the SALT sensor (clean the sensor window). Replace the drum unit
(check its connections). Replace the ITB (clean it).
xx35 SALT sensor trouble or a broken/
disconnected wire
Replace the SALT sensor (clean it).