Installation Manual, Instruction Manual, Instruction Manual, Instructions For Use Manual, Instructions For Use Manual, Instruction manual, Installation Manual, Instruction Manual, Instruction Manual, Instruction Manual, Instructions For Use Manual, Instruction Manual, Instruction Manual, Safety Manual, Instruction Manual, Instruction Manual, Instruction Manual, Instruction Manual, Instructions for use manual, Instruction Manual, Instruction Manual, Instruction Manual, Instruction Manual, Instruction Manual, Installation Manual, Instruction Manual
Manual is about: ELEVATOR DRIVE
of
72
6.6 Circuit examples
6.6.1 Instructions to the following circuit example
In the following circuit example the drive converter is connected via the F5-AFE with a
LCL filter to the supply system. The temperature monitoring of the LCL filter is done by
the F5-AFE.
The inputs and outputs are pre-programmed for the following circuit example.
ATTENTION
For a safe function of the AFE system use models with positively driv-
en auxiliary contacts for power contactors K2 and K3 (pre-charging and
main contactor). Thus, safe interlocking at defective contactor is guaran-
teed even in case of failure.
41
CONNECTION OF THE COMbIVERT F5-AFE