KEB COMBIVERT F5 Instructions For Use Manual - Attention
Other manuals for COMBIVERT F5:
Installation Manual, Instruction Manual, Instruction Manual, Instructions For Use Manual, Instructions For Use Manual, Instruction manual, Installation Manual, Instruction Manual, Instruction Manual, Instruction Manual, Instructions For Use Manual, Instruction Manual, Instruction Manual, Safety Manual, Instruction Manual, Instruction Manual, Instruction Manual, Instruction Manual, Instructions for use manual, Instruction Manual, Instruction Manual, Instruction Manual, Instruction Manual, Instruction Manual, Installation Manual, Instruction Manual
Manual is about: ELEVATOR DRIVE
of
72
Size
Housing
P
N
I
N
C
int
Load-shunt
Max. charg-
ing current
R
Type
400V
kW
A
uF
Ω
–
A
22
R
55
115
4,950
5.0
–
–
23
R
75
150
6,350
5.0
–
–
24
R
90
180
8,400
5.0
–
–
23
U
75
150
6,350
5.0
–
–
24
U
90
180
8,400
5.0
–
–
25
U
110
210
9,900
2.5
–
–
26
U
132
250
11,700
2.5
–
–
27
U
160
300
14,100
2.5
–
–
28
P
200
370
16,200
5.8
–
–
29
P
250
460
19,800
5.8
–
–
30
P
315
570
19,800
5.8
–
–
32
P (M+S)
400
710
39,600
2.9
–
–
33
P (M+S)
450
800
39,600
2.9
–
–
34
P (M+S)
500
890
39,600
2.9
–
–
35
P (M+S)
560
1000
39,600
2.9
–
–
36
P (M+S+S)
630
1150
59,400
1.9
–
–
Legend
P
N
Rated power
I
N
Rated current
C
int
real capacity
Table 17:
Technical data of KEB COMBIVERT drive converters
ATTENTION
A restart for AFE with NTC is allowed only after 5 minutes.
58
DIMENSIONING