Mediaedge Decoder User Manual - page 135
- 135 -
MEDIAEDGE Decoder
■ Firmware update from the USB storage and the SD card
(Firmware update from a USB/SD drive)
After the USB storage (USB memory, USB HDD, etc.) or the SD card is
inserted into the USB terminal, the firmware update will be started when the
firmware file name is entered.
When ’*’ is entered, the file list in the connected USB storage (file of extension.
system) will be displayed. When only ENTER is entered, it will return to the top
menu screen.
■ The firmware update by the HTTP/FTP client function
(Firmware download via HTTP/FTP)
To download the firmware from HTTP/FTP server, specify the path of firmware
in the URL entry screen.
Ex.):
FTP server:mediaedge-svr
Folder to log in with FTP:C:\temp\ftpwork
Absolute path of firmware:C:\temp\ftpwork\firm\decoder.x.x.x.system
> URL to be entered:
ftp://mediaedge-svr/firm/decoder.x.x.x.system
The update of the firmware will be started when the download is completed.
When the update of the firmware is finished, select 0: Restart and restart the
MEDIAEDGE Decoder. When only ENTER is entered, it will return to the top
menu screen.
■ Ping (Sending ICMP echo requests)
This is a function to send the Ping (ICNP echo request) packet and check on
the network status.
=== Ping (Sending ICMP echo requests)===
Enter a target IP address ->
Enter the IPv4 address of the destination that you want to check the status