Connect the power supply harness (optional part:
26011-0246) to the capacitor lead connector of the
main harness.
•
Connect the power supply harness (optional part:
26011-0246) to the 12 V battery.
•
Connect the O/Y lead (red cap) to the positive (+)
terminal first.
A. Power Supply Harness (Optional Part:
26011-0246)
B. Capacitor Lead Connector
C. 12 V Battery
NOTE
○
Use a fully charged battery when conducting self
-diagnosis. Otherwise, the light blinks very slowly
or doesn’t blink.
○
Keep the self-diagnosis terminal grounded during
self-diagnosis.
•
Disconnect the self-diagnosis connector (Y lead).
A. Self-diagnosis Connector (Y Lead)