JA-63 „PROFI“ Alarm System
- 12 -
MGK51404
10.7 Radio signal jamming testing
sequence: 2 6 x
When this function is enabled, the control panel will indicate trouble if the working band is jammed for more than 30
seconds. Jamming will trigger an alarm when the control panel is armed. Do not enable this testing if the control panel
does not have a radio module.
options:
2 6 1 testing
enabled
2 6 0 testing
disabled
Note: in large cities and some other locations the system can be randomly jammed from time to time (near TV or radio station, GSM
cell station etc.). In these cases the control panel can work without any problems because all important data is repeated, but the
jamming test should not be enabled. The level of the signals and interference can be observed using the Comlink software (see17)
Factory default setting: disabled
10.8 Regular
communication
checking
sequence: 2 7 x
The control panel will check communication regularly with all enrolled items (detectors, keypads, siren etc.) when this
function is enabled. If communication is lost with any item, the control panel will indicate the fault of this item (when armed
it will also trigger an alarm). Do not enable this checking if the control panel does not have a radio module.
options:
2 7 1 checking
enabled
2 7 0 checking
disabled
Note: in large cities and some other locations with a strong radio interference the communication can be jammed randomly. The control
panel can detect such a strong interference as a temporary loss of communication with an item. Even in this case, the system is usually
able to work without any problems because all important data is repeated, but the communication check should not be used.
Factory default setting: checking disabled
10.9 Reset
enabled
sequence: 2 8 x
The factory default reset (see 15) can be disabled. This way no unauthorized future programming of the control panel
will be possible.
options:
2 8 1 reset
enabled
2 8 0 reset
disabled
Warning: if the Master or Service code is forgotten when the reset is disabled. The reset of the control panel will be possible only by
the manufacturer.
Factory default setting: reset enabled
10.10 Arming control of a subsystem
sequence: 2 9 0
A wireless master control panel receives event signals (alarms, tampering, faults, low battery) from a JA-6x subsystem if
enrolled - see 10.1 a 10.11. This will cause the same kind of event on the master control panel and J will be indicated as
the source of the event on the keypad.
The master and slave control panels can be either armed and disarmed as two independent systems or the slave
system can follow the arming and disarming of the master. If the master should rule arming of the slave subsystem, make
the following settings:
a. enroll a subsystem to the master‘s J position (see 10.1 and 10.11),
b. place the master panel into the programming mode (P is indicated),
c. enter the enrolling mode in the sub-control panel (pressing key 1 while in the programming mode)
d. enter 290 on the master control panel – this way the master will enroll to the slave sub-control panel as a
wireless controller (to the first free position of c1 to c8)
e. turn both systems to standby mode and check that the subsystem will arm after the master control panel is
armed (in 2 seconds). Check the same for disarming
Notes:
•
Master control panel generates wireless commands Arm and Disarm the same way as a remote control RC-11. The control
panel transmits these commands only if it has a subsystem enrolled in its position J.
•
The Arm command is generated when the master control panel is completely armed and also at the end of an alarm while
the system remains completely armed (automatic alarm timeout). The Disarm command is generated when the master
control panel is disarmed, when it is partly armed (home arming or one section arming if it is split) and also in the end of an
alarm while the system is disarmed (manual termination of the alarm).
•
The subsystem can also be operated by its other controllers (remote controls, keypads) if there are any. For better
understanding you can simply imagine, that the master control panel is just another remote control..