Jablotron JA-63 „PROFI“ Installation Manual - page 15
JA-63 „PROFI“ Alarm System
- 15 -
MGK51404
(for example permanently triggered detector, lost communication etc.) will remain displayed on the keypad. If the user
ignores this warning, the system will arm after the exit delay, then the problematic item will be bypassed for this arming
period. After disarming in such a mode, three beeps will be generated as well.
When the indication is not selected, the problematic item will be bypassed when arming with neither warning nor alarm.
If a permanently activated detector is deactivated during arming (for example your main door is not closed), the bypass of
this detector will be canceled automatically and the detector will be ready to trigger an alarm after it is activated (if you
close the door after the system is armed).
options:
3 9 1 warning
enabled
3 9 0 warning
disabled
Note: if this indication is enabled, the problems will also be indicated if there are any when leaving the programming or user mode.
Factory default setting: warning disabled
10.22 Control panel splitting
sequence: 690 x
The control panel can be split into 2 independent sections A and B, with a shared common area C. This way the system
can be operated by two independent user groups. In fact the system in this mode works like two independent systems. If
the system is split into sections with this setting, it is possible to address detectors (both wireless and wired), user codes
and remote controls to the individual sections. Use the following sequences.
options:
6 9 0 0 no splitting (partial arming available in this mode)
6 9 0 1 splitting to sections A, B and common C (C is armed only when both A and B are armed)
Factory default setting: no splitting
10.23 Only first source of alarm is recorded
sequence: 691 x
When any item triggers the alarm 4 times in a row the system will bypass it until any other events occurs. But it is
possible to set the limit at the incoming events so only the very first event during the entire alarm will be recorded. This
function is useful especially if the system contains a GSM communicator in order to decrease quantity of the SMS
messages. This setting is valid for all kinds of the alarm.
Options:
6 9 1 0 All sources of alarm are recorded
6 9 1 1 Only first source of alarm is recorded
Factory default setting: All sources of alarm are recorded
10.24 Alarm triggered by opened zone when arming
sequence: 692 x
If the “indication of system problems when arming” (see 10.21) is enabled, it is also possible to test the status of the
detectors after expiring the exit delay. If any item is activated then in case of instant zone the alarm will be triggered
immediately, in case of delay zone the entry delay will start.
Options:
6 9 2 0 test disable
6 9 2 1 test enable
Factory default setting: test disabled
10.25 Addressing of wireless detectors to sections
sequence: 61 nns
If the control panel is split (see 10.22) and is equipped with a radio module, the wireless detectors can be addressed to
sections by entering:
61 nns
where: nn = wireless detector zone number: from 01 to 16
s = section: 1 = A, 2 = B, 3 = C (common section - it is armed only when both A and B are armed). If the
control panel is not split, and s=2 is selected, this detector will be bypassed while partial arming.
Example: to address wireless detector zone number 3 to section A enter: 61 031
Factory default setting: detectors 1 - 10 are addressed to A, detectors 11 - 16 are addressed to B