Jablotron JA-63 „PROFI“ Installation Manual - page 19
JA-63 „PROFI“ Alarm System
- 19 -
MGK51404
12.2 Automatic SMS sending
sequence: 7xxx....xxF5
If Jablotron’s SMS server service is provided in your country (check with your distributor), the following setting allows the
control panel to send alarm text messages (SMS) automatically to a desired mobile phone:
7 xx…x F9 yy....y F7 00F9 F7zz..z F5
where:
xx…x = telephone number of the SMS server (check with your distributor if this
service is provided in your country)
F9 = separator (recognition of server’s reaction)
yy…y = mobile phone number (where the SMS should be sent to)
F7 = event code separator
00F9 = automatic event code – control panel will insert there a digital code
representing the alarm (depends on setting in section 12.4)
F7 = ID separator
zz..z = optional ID number which will be sent as a part of the SMS (ending). ID
distinguishes which alarm system sent the SMS). If ID is not required, do not
enter
F5 = storing of the sequence to memory 5 (32 digits can be stored to memory 5 as a
maximum - separators F9 and F7 takes only 1 digit each).
How the SMS server woks: when activated, the control panel dials the SMS server. After the connection is established, it sends
telephone number of the mobile phone, to which the SMS should be sent. Then the control panel specifies what happened by a digital
code and in the end the ID number is transferred (if programmed). In this moment the SMS server makes corresponding text message
and this message is sent to the GSM network.
Example: If SMS server number is 483559876, SMS should be sent to number 606123456 and ID number of the
installation is 41 enter :
7 483559876 F9 606123456 F7 00F9 F7 41 F5
Deleting of automatic SMS sending – to erase SMS sending enter:
7 F0 F5
Note: memory 5 can also be used to dial a Pager instead of SMS sending. To dial a Pager enter 7 xx..x F9 zzz....z F5 wherexx..x is
number of the provider, zz…z is number of the pager and code of the message (check with a local Pager provider for details). Pause in
the dialing can be entered with F0,
∗ with F7 and # with F8. Pager dialing can be deleted with 7 F0 F5.
Factory default setting: SMS sending (Pager dialing) is erased.
12.3 Voice message(s) recording
sequence: 8x
You can record two different voice messages (10 sec. each). Depending on the setting in section 12.4, a particular
message will be sent under different situations. Recording of the messages:
a) enter 85 on the keypad
b) press and hold push button on the X module
c) speak towards the module (max. 10 s)
d) release the button, message will play back
This results in the recording of message number 1. To record message 2 enter 86 in step a)
If you prefer sending only one, but longer, message (20 sec.), record message by entering 84 in step a). By
programming as described in section 12.4 you can specify which alarms will trigger the sending of a message.
Notes:
•
Make the messages brief and clear. The dialer repeats the message to each called number for 40 seconds.
•
The voice messages are stored in non-volatile memory and can be changed when ever you want to by repeating the above steps.
•
The existing messages can be played by momentarily pressing the push button on the X module (or by entering F9 while in stand
by mode).
12.4 Triggering of voice and SMS messages sending
sequences: 9 y x
With sequences 91x to 95x you can select which alarms will trigger the telephone dialer to call and what will be sent.
Enter: