12 Voice & SMS messages setting
A control panel equipped with the X module can automatically send 2 voice and 5 short text messages (or dial a Pager)
. The most convenient programming of the dialer is via a connected PC using the Comlink software (see section 17).
Programming can also be performed manually from the keypad:
• Enter the programming mode (F 0 Service Code, factory default = 6060), indicated by „P“
• Any unfinished programming sequence can be terminated by pressing the N key.
• To exit the programming mode, press the N key („P“ will turn off). If any fault is indicated when you try to exit
the programming mode, the control panel will inform you about the problem (see 10.21).
• Telephone numbers and messages can also be set up in the User Mode when enabled (see section 10.6)
List of the voice & SMS sending parameters
Function sequence
options
factory d.
note
Dialing method
90x
901 = tone 900 = pulse
tone
valid also for
CMS dialing
Triggering of the dialer with a Panic alarm
91x
0=nothing, 1=voice1 + SMS,
2=voice2, 3=SMS only
911
Triggering of the dialer with an Intruder alarm
92x
0=nothing, 1=voice1 + SMS,
2=voice2, 3=SMS only
921
Triggering of the dialer with a Fire alarm
93x
0=nothing, 1=voice1 + SMS,
2=voice2, 3=SMS only
931
Triggering of the dialer with a Tamper alarm
94x
0=nothing, 1=voice1 + SMS,
2=voice2, 3=SMS only
941
Triggering of the dialer with a Technical alarm
95x
0=nothing, 1=voice1 + SMS,
2=voice2, 3=SMS only
951
Telephone line checking enabled
99x
990=NO 991=YES
NO
Store telephone numbers for voice message
7xx..x F y
xx...x = tel. number, y =
memory 1 to 4, pause = F0
Automatic SMS sending
7x..xF9y..yF7
00F9F5
x..x=SMS server number
y..y= mobile phone number
1:
2:
3:
4:
5:
Erase telephone number
7F0Fy
y = memory 1 to 5, entering
7F0F0 erases all
Record voice messages (1 & 2)
mess. 1 enter 85 then push button on X module and speak (10sec.)
mess. 2 enter 86 then push button on X module and speak (10sec.)
Dialer testing
89
12.1 Telephone numbers for voice message sending
sequence: 7xxx....xxFy
Store telephone numbers for voice message by entering:
7 xx... xx F y
where xx...xx = telephone number
y = memory number from 1 to 4
A telephone number can have a maximum of 16 digits. A pause can be entered with F0
Example: to store tel. number 0 123456 to memory no. 2 enter: 7 0 F0 12345 F2
Note: enter a pause (F0) after the last digit of a number which is calling a mobile phone. This way the number will be called only
once and the dialer will not check the line signals (some mobile phone systems do not generate standard telephone line signals).
To delete a telephone number enter:
7 F0 Fy
where y is a memory number from 1 to 4
entering 7 F0 F0 will erase all tel. numbers, including the SMS settings
When activated, the dialer will disengage all other devices hooked up to the phone line. It will then, one by one, call all programmed
numbers and play the user recorded message which corresponds to the event. If the dialer makes a successful connection to a
programmed number, it will not call that number again. If the number is busy, the dialer will make 3 more attempts to call it. Empty tel.
number memories are skipped. If all memories are empty, the dialer is completely disabled. If the dialer is programmed to also
communicate with a monitoring station, the data will first be sent to the monitoring station..
Factory default setting: all telephone numbers are deleted.