Protocol and Format setting
sequence: 03
This sequence is used to select the communication protocol and format. Its structure is as follows:
03 x y
x - protocol (0 – 9, see table bellow)
y - format (0 - 3 see table on right
)
Protocols
x Name
Hand-
shake
Data Kiss
off
Speed format
0
Ademco Slow
(Silent Knight)
1400Hz 1900Hz 1400Hz 10bps Next
table
1
Ademco Fast
1400Hz 1900Hz 1400Hz 14bps Next
table
2
Telemax
2100Hz 1650Hz 2100Hz 10bps Next
table
3
Franklin
2300Hz 1800Hz 2300Hz 20bps Next
table
4 Radionics 2300
2300Hz 1800Hz 2300Hz 40bps Next
table
5 Radionics 1400
1400Hz 1900Hz 1400Hz 40bps Next
table
6
DTMF 2300
2300Hz DTMF 2300Hz DTMF Next
table
7
Surgard*
2300Hz DTMF 2300Hz DTMF 4/3
8 Ademco express*
Dual tone
DTMF
1400Hz
DTMF
4ID/2
9
Contact ID*
Dual tone
DTMF
1400Hz
DTMF
CID
*
fixed format, “y” is
arbitrary (0 is recommended)
Notes:
•
1/ Some Monitoring Station receivers do not support all formats.
•
2/ Logic of the format marking - 4/2 means that an account code has 4 digits and an event report code has 2 digits.
•
3/ Changing of a format erases the internal communicator’s memory of non reported events and sends a “Reset“ reporting
code (051) to the Monitoring Station.
Factory setting: 90 (Contact ID)
14.4
Re-dialing pause setting
sequence: 04
If a dialer is triggered it attempts to make a connection (alternating between the primary and the backup telephone number). If
it is not possible to make a connection after 8 attempts, a pause is initiated. After this pause the dialer will attempt again. If any
event triggers the communicator during the pause, the pause ends immediately. The pause length can be set in the following
way:
0 4 x
x – time multiplied by 10 minutes (from 1 to 9, example 3 = 30 minutes)
Factory setting: 1 = 10 min.
14.5
CMS phone number entering
sequence: 06
Central monitoring station modem phone numbers can be stored by entering the following sequence:
0 6 x x .... x F y
xx...x – Central Monitoring Station phone number (up to 16 digits)
y is 1 for primary phone number memory
2 for back up phone number memory
Pause (3 sec.) can be inserted into the telephone number by entering F0. It is also possible to insert the
∗ tone by F7 or
the # tone by F8 if requested forDTMF dialing.
Example: number 02 123456 as main Monitoring Station number is entered with 06 02 F0 123456 F1.
Phone number erasing
0 6 F 0 F y
y is 1 to erase the primary telephone number
2 to erase the back up telephone number
Note: Changing of a phone number erases the internal communicator’s memory of non reported events and sends a “Reset“
reporting code (051) to the Monitoring Station.
Factory setting: both numbers are erased
Formats
y
format
reports structure
0
3/1
Major events only
xxx R
1
3/2
All events
xxx rc
2
4/1/1
Major events with autom.
source identification
xxxx Rn
3
4/2
All events
xxxx rc
xxxx = account number
R = major event code (only first digit counts)
rc = detailed event code (two digits)
n = source identification (generated automatically)
Surgard protocol has structure: xxxx E rc, where
E is a group identifier (generated automatically)
E Event
Note
1 Fire
2 Panic
3 Alarm
General
4
Arming
Incl. Partial
5 Disarming
6
Failure
Power failure, RF jamming …
8
Report
Enter/Exit service mode …
9
Restore
End of alarm, panic …
A
Test
24 hour test