Jablotron JA-63 „PROFI“ Installation Manual - page 16
JA-63 „PROFI“ Alarm System
- 16 -
MGK51404
actions' table
a no
splitting
split
system
0
no action
no action
1
arm all
arm all
2 disarm disarm
all
3 partial
arming
arm A
4 partial
arming
arm B
5 disarm disarm
A
6 disarm disarm
B
10.26 Addressing of the user codes to sections
sequence: 62 nns
If the control panel is split (see 10.22), the user codes can be addressed to sections A or B by entering:
62 nns
where: nn = user code number: from 01 to 14
s =section: 1 = A, 2 = B
Notes:
• If the control panel is not split, this setting has no effect.
• Master code (MC) can not be addressed. If the system is split, the use of MC
will arm all sections if no section is armed or it will disarm all sections if any
are armed. If you want to operate only section A with master code, enter F1
MC and F2 MC for section B.
Example: to address user code number 4 to section A enter: 62 04 1
10.27 Addressing of wireless controllers to sections
sequence: 63 nns
If the control panel is split (see 10.22) and is equipped with a radio module, the wireless controllers (RC-11, RC-22 and
JA-60D) can be addressed to A or B section by entering:
63 nns
where: nn = number of the enrolled controller from 01 to 08 (c1 to c8)
s = section: 1 = A, 2 = B
Notes:
• If the control panel is not split, this setting has no effect
• For the JA-60F keypad this setting has no effect (its user codes are determined by 62 nns setting)
• The JA-60D keypad is effected the same way as RC-11 remote controls (is addressed to a selected section)
Example: to address controller number 5 to section A enter: 63 051
Factory default setting: all wireless controllers are addressed to section A
10.28 Automatic arming / disarming setting
sequence: 64 nahhmm
The control panel can automatically arm and disarm for a requested period of a day. Up to ten instructions (time &
action) can be programmed in the period of one day by entering:
64 nahhmm
where: n = instruction number from 0 to 9
a = action (see the actions' table)
hh = hours (from 00 to 23)
mm = minutes (from 00 to 59)
Notes:
• If any automatic action is selected, it will be preformed everyday at the programmed time, following the internal control
panel clock.
• The automatic arming and disarming can be overridden manually anytime (by a user code or a remote control)
• If the control panel is in the requested arming mode before the action time, performance of the programmed action
will not change the arming
Example: to program an automatic complete arming of the system at 21:15 everyday enter: 64 0 1 21 15
Factory default setting: all instructions are set for no action