Jablotron JA-63 „PROFI“ Installation Manual - page 20
JA-63 „PROFI“ Alarm System
- 20 -
MGK51404
9 y x
where
Notes
•
Final texts of alarm SMS are generated by the SMS server (providers computer) – based on the digital code sent by the alarm
system (check with provider for more details)
•
If only one long voice message was recorded by using code 84 as described in section 12.3, then this message will be sent
when x=1 or x=2
•
Voice messages are sent step by step to all telephone numbers programmed as described in section12.1
•
SMS message is sent to a mobile phone number programmed as described in section 12.2
Example: if the dialer should send an SMS and voice message 1 when intruder or panic alarm is triggered, voice
message 2 in the case of fire and only an SMS in the case of technical alarm, enter: 911 921 932 943
Factory default setting: all alarms will trigger sending of voice message 1 and SMS (911, 921, 931, 941, 951).
12.5 Dialing
method
sequence: 9 0 x
Enter:
9 0 1 for
tone dialing
9 0 0 for
pulse dialing (this option is blocked for some countries)
Note: this dialing method setting is also valid for Central monitoring station communications.
Factory default: tone dialing
12.6 Telephone line checking
sequence: 9 9 x
If this function is enabled, the dialer will check regularly if the telephone line is ready to make a phone call. If the line is
not ready for more than 15 minutes, the keypad will indicate a telephone line failure (failure L). A non-working telephone
line or a phone conversation or Internet connection longer than 15 minutes can cause a fault.
options:
9 9 1 checking
enabled
9 9 0 checking
disabled
Note: this setting is also valid when the dialer is used for Monitoring station communications as well as remote PC access
Factory default setting: checking disabled
12.7 Telephone dialer testing
sequence: 8 9
After entering code 89 the dialer will call all programmed numbers and will play voice message 2. It will also send a
SMS message if programmed. The telephone line signals will be audible from the control panel’s built in speaker during
the test (if the dialer is triggered by an alarm in normal operation, it will call silently).
If you prefer testing with voice message 1 enter code 88.
Testing can be terminated with the N key.
13 To enable a remote computer to dial in
When the user or installer wants to dial in to the installation from their computer or a remote JA-60E keypad via a
JA-60U modem (see section 18), the following parameters should be programmed.
The most convenient programming is via a connected PC using the Comlink software (see 17). Programming can also be
performed manually:
• Enter the programming mode when disarmed (F 0 Service Code, factory default 6060), indicated by a ”P“
• Any unfinished programming sequence can be terminated by the N key.
• To exit the programming, press the N key (“P“ will turn off).
Dialing in parameters
Function sequence
options
factory d.
Incoming call reaction
0 5 x
0=never, 1= second call, 2-6 =
after ring No. 2 - No.6
disabled
Remote access code (8 digits)
0 7
xxxxxxxx
any 8 digits code
00000000
y
Alarm
1
Panic – silent
2
Intruder
3
Fire
4
Tampering
5
Technical trouble
x reaction
0
no reaction
1
voice1 and SMS
2
voice 2 only
3
SMS only